Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    EXPLOSIVE Search Results

    EXPLOSIVE Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    thermal fuses color coding

    Abstract: barrier network fuse axial thermal fuse 125OC 242 Series fuses color coding axial fuse color code
    Text: Special Application Fuses 242 Series Barrier Network Fuse Barrier Network Fuse 242 Series Description The 242 Series hazardous area barrier network fuse offers a range of fuses designed to enable greater safety operating electronic equipment within potentially explosive


    Original
    PDF EN50020) JDYX2-10480) 125OC. 125OC MIL-STD-202F 050UAT1 com/series/242 thermal fuses color coding barrier network fuse axial thermal fuse 125OC 242 Series fuses color coding axial fuse color code

    Untitled

    Abstract: No abstract text available
    Text: PSE EX 19 Metal Line Switches www.schurter.com/PG70 Piezo Switch for Explosive Environments PSE M19 EX Description - Piezo switch certified according to ATEX and IECEx ␍ - Assembly by mounting with nut ␍ - Pins, Crimp Terminal male, AMP ␍ Approvals - EMC: EMC directive 2004/108/EWG


    Original
    PDF com/PG70 2004/108/EWG RS103,

    WORKING PRINCIPLE OF proximity sensor

    Abstract: flow nozzle catologue 0 281 002 507 0 281 002 401 49100
    Text: Position detectors www.crouzet.com 21 Pressure decay sensor • 100 % pneumatic Also available in ATEX version for use in potentially explosive atmospheres in accordance with 94/9/EC Directive Pressure decay sensor 81 504 025 Symbol Characteristics Operating pressure


    Original
    PDF 94/9/EC WORKING PRINCIPLE OF proximity sensor flow nozzle catologue 0 281 002 507 0 281 002 401 49100

    quint-diode mtbf

    Abstract: QUINT-PS-100 CISPR22
    Text: 1-Phase Power Supply, Primary Switch Mode for Use in Potentially Explosive Areas QUINT-PS-100-240AC/24DC/5/EX QUINT POWER provides: • Preventive function monitoring through professional signaling • Global use due to a wide range input • A high level of operational safety even in complex


    Original
    PDF QUINT-PS-100-240AC/24DC/5/EX quint-diode mtbf QUINT-PS-100 CISPR22

    FSWA9EX

    Abstract: inductance proximity sensor INTRINSIC SAFE CIRCUIT inductance proximity sensor ATEX explosive
    Text: Intrinsic Safety - Magnetic proximity sensors for potentially explosive environments FSW Series • M12 housing in stainlees steel AISI 303 • Output function NO • For use in zone 0 or zones 1 and 2 • Approval: Product Description Ordering Key The frontal magnetic sensors


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Model 92/93 Revere Compression Load Cell FEATURES • Capacities: 50k lbs and 100k lbs • Environmental protection: IP68 DIN 40.050 • Material: Stainless steel • Hermetically sealed • Optional ❍❍ FM approved for use in potentially explosive atmospheres


    Original
    PDF 27-Apr-2011

    AN017 Application Note, Intersil Corporation

    Abstract: AN016 intersil AN017 intersil 4 digit display block diagram with icl7107 intersil AN017 ICL7135 intersil AN016 AN-017 ICL7106 application notes ICL-7107
    Text: Selecting A/D Converters TM Application Note February 1999 AN016 Introduction Case 1 One of the popular pastimes of the nineteen sixties was to predict the explosive growth of digital data processing, fed by the newly-developed semiconductor MSI circuits, and the


    Original
    PDF AN016 AN017 Application Note, Intersil Corporation AN016 intersil AN017 intersil 4 digit display block diagram with icl7107 intersil AN017 ICL7135 intersil AN016 AN-017 ICL7106 application notes ICL-7107

    precision zener diode

    Abstract: polyswitch fuse
    Text: APPLICATION NOTE PolyZen Device Helps Protect Automotive Infotainment Peripherals The explosive growth of portable, battery-powered infotainment peripherals has resulted in a demand for more robust and reliable circuit protection. GPS systems, smart phones, play stations and portable


    Original
    PDF RCP0026E precision zener diode polyswitch fuse

    atex optocoupler

    Abstract: No abstract text available
    Text: V I S H AY I N T E R T E C H N O L O G Y, I N C . OPTOCOUPLER Optocoupler - ATEX Certified for Gas and Dust CNY65Exi High-Voltage Isolation for Potentially Explosive Environments ATEX Certified The CNY65Exi provides very high voltage isolation and is ATEX certified per 94/9/EC guidelines for use in potentially


    Original
    PDF CNY65Exi CNY65Exi 94/9/EC VMN-PT0300-1403 atex optocoupler

    kema10atex0050

    Abstract: No abstract text available
    Text: Data sheet. MH KTB MH 221513 S4E0 Weidmüller Interface GmbH & Co. KG Klingenbergstraße 16 D-32758 Detmold Germany Fon: +49 5231 14-0 Fax: +49 5231 14-292083 www.weidmueller.com Stainless steel housings for the use within explosive-risk zones


    Original
    PDF D-32758 kema10atex0050

    XSAV11373EX

    Abstract: NY320N2RB1 XS630B1PAL10EX XCKJ390559H29EX XCKJ390511H29EX XCKD3902P16EX XSAV12373EX XCKJ390541H29EX XAWF174EX XCKM3915H29EX
    Text: The essential guide for explosive atmospheres ATEX Dust helping you easily select the right product 2008 Explosive atmospheres A reference for installations in ATEX Dust explosive atmospheres. What is an explosive atmosphere according to the Directive? It is the mixing with air, in atmospheric conditions, of flammable substances in the form of gas,


    Original
    PDF 99/92/EC 140DII33000 140DIO33000 140AII33000 140AII33010 140AIO33000 DIA4ED2040603EN XSAV11373EX NY320N2RB1 XS630B1PAL10EX XCKJ390559H29EX XCKJ390511H29EX XCKD3902P16EX XSAV12373EX XCKJ390541H29EX XAWF174EX XCKM3915H29EX

    5SDD36K5000

    Abstract: No abstract text available
    Text: 5SDD 36K5000 5SDD 36K5000 Old part no. DV 889B-3600-50 Rectifier Diode Properties § Industry standard housing § Suitable for parallel operation § High operating temperature § Low forward voltage drop § Explosive protection Key Parameters = 5 000 V RRM


    Original
    PDF 36K5000 889B-3600-50 36K5000 36K4800 1768/138a, TS-DV/211/06 Jul-10 5SDD36K5000

    dt 92 abb

    Abstract: No abstract text available
    Text: 5SDD 36K5000 5SDD 36K5000 Old part no. DV 889B-3600-50 Rectifier Diode Properties Industry standard housing Suitable for parallel operation High operating temperature Low forward voltage drop Explosive protection Key Parameters V RRM = 5 000 I FAVm = 3 638


    Original
    PDF 36K5000 889B-3600-50 1768/138a, DV/211/06a Aug-11 dt 92 abb

    Baseef02ATEX0071U

    Abstract: No abstract text available
    Text: Special Application Fuses 259 Series Safe-T-Plus Fuse Safe-T-Plus Fuse 259 Series Baseefa Description The Safe-T-Plus 259 Series offers a range of encapsulated fuses designed to enable greater safety for operating electronic equipment within potentially explosive environments. Originally


    Original
    PDF 635mm Baseef02ATEX0071U

    spst push button

    Abstract: REED SWITCH CURRENT SENSOR "Series REED SWITCH" spst reed relay flammable gas sensor explosive intrinsically safe transistor k08 MK08
    Text: ExEx-Approved Intrinsically Safe Push Button Reed Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction Many facilities, particularly manufacturing environments where dust particles or explosive atmospheres may exist, represent real challenges when it comes to


    Original
    PDF 94/9/EC spst push button REED SWITCH CURRENT SENSOR "Series REED SWITCH" spst reed relay flammable gas sensor explosive intrinsically safe transistor k08 MK08

    car sensor ignition

    Abstract: cap sensing position sensor reed switch gas sensors NO gas sensor MK18 design of ignition and fuel system
    Text: Gas Tank Lid Monitoring Sensor REED RELAYS REED SENSORS REED SWITCHES Introduction In and around the gas tank and its filling lid is consider a highly explosive area. Anything that can possible cause a spark could potentially ignite the fuel. Use of an electromechanical sensor to detect if the lid and fuel cap are in place could


    Original
    PDF MK20/1 car sensor ignition cap sensing position sensor reed switch gas sensors NO gas sensor MK18 design of ignition and fuel system

    EFD34

    Abstract: DS161R Motor Control Center wiring diagram abb TFK catalog EX-88 WESTINGHOUSE motor life line westinghouse mcp breaker TFK 543 TC236
    Text: Industrial Control & Circuit Breakers Section C Innovative, intelligent NEC and IEC solutions safely and efficiently control power and protect circuits in explosive, wet, and corrosive environments worldwide. New Products in the Control Product Line Section


    Original
    PDF ACE20 EFD34 DS161R Motor Control Center wiring diagram abb TFK catalog EX-88 WESTINGHOUSE motor life line westinghouse mcp breaker TFK 543 TC236

    Untitled

    Abstract: No abstract text available
    Text: DFC Flat Battery support Super Capacitors APPLICATIONS •        Extends battery life up to 3 times Handheld devices DC motors RFID systems Pulse power Automatic Meter Readers GPS Medical equipment FEATURES  High Capacitance  Non explosive


    Original
    PDF

    vhdl code for multiplication on spartan 6

    Abstract: CY7C1302 XAPP183 XAPP173
    Text: White Paper: Spartan-II R WP111 v1.0 February 16, 2000 Introduction Spartan-II Family as a Memory Controller for QDR-SRAMs Authors: Amit Dhir, Krishna Rangasayee The explosive growth of the Internet is boosting the demand for high-speed data communication systems. While RISC CPU speeds have exceeded clock rates of 500 MHz,


    Original
    PDF WP111 com/xapp/xapp173 xapp174 xapp179 wp106 XAPP183: vhdl code for multiplication on spartan 6 CY7C1302 XAPP183 XAPP173

    ASIC for RF proximity Fuze

    Abstract: XM773 fuze explosive squib RF proximity Fuze MIL-STD-1316 chip slapper M732A2 thermoelectric generator detonator FMCW Radar
    Text: National Semiconductor Application Note 761 Marc Dennis Bob Hanrahan Chris Brackmann November 1991 1 0 INTRODUCTION Fuzing mechanisms are devices used to ‘‘safe’’ ‘‘arm’’ and detonate explosive military munitions such as missiles mines demolition charges explosive shells ranging in size


    Original
    PDF 20-3A ASIC for RF proximity Fuze XM773 fuze explosive squib RF proximity Fuze MIL-STD-1316 chip slapper M732A2 thermoelectric generator detonator FMCW Radar

    iMOTION

    Abstract: mobile hardware integration 324M
    Text: Applications Processors Design Support Wireless Media Player for i.MX-Based Devices Overview The cellular market continues its explosive growth with a wide range of products and an ever-expanding set of features. These products create a whole host of opportunities for


    Original
    PDF

    lm317 pnp Transistor

    Abstract: AN-1148 LM1085 LM317 LM340 LP2985 LP2989 bode plot technique of plot LM317 ldo
    Text: National Semiconductor Application Note 1148 Chester Simpson May 2000 Introduction The explosive proliferation of battery powered equipment in the past decade has created unique requirements for a voltage regulator that cannot be met by the industry standards like the LM340 or the LM317. These regulators use an


    Original
    PDF LM340 LM317. lm317 pnp Transistor AN-1148 LM1085 LM317 LP2985 LP2989 bode plot technique of plot LM317 ldo

    Untitled

    Abstract: No abstract text available
    Text: Application: The Dialight SafeSite LED Bulkhead luminaire with its low profile, rugged design ensures long life and high reliability for a wide variety of applications requiring INMETRO certification. Offered in 22 Watt and 34 Watt versions, it is ideally suited for oil platforms, explosive environments,


    Original
    PDF 00-277V 4V-48V 180mm Catalogs/Illumination/MDEXSSWPAIM001 MDEXSSWPAIM001

    Untitled

    Abstract: No abstract text available
    Text: Static control for hazardous areas * Cenelectrex" a VESX10 The Cling-on Clam p ATEX approved clamp for use in potentially explosive atmosphere zones. II 1 GD T6 The VESX10 ‘Cling-On’ Clamp is a heavy-duty earthing clamp used for bonding of drums, kegs, tanks, IBC and vehicles.


    OCR Scan
    PDF VESX10 e233-339 210mm,