Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    2EU30 Search Results

    SF Impression Pixel

    2EU30 Price and Stock

    Schaffner FN9222EU-3-06

    PWR ENT RCPT IEC320-C14 PANEL QC
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    DigiKey FN9222EU-3-06 Tray 84 1
    • 1 $10.68
    • 10 $8.701
    • 100 $7.69425
    • 1000 $6.3
    • 10000 $6.3
    Buy Now
    Mouser Electronics FN9222EU-3-06
    • 1 $12.59
    • 10 $9.72
    • 100 $8.43
    • 1000 $6.47
    • 10000 $6.47
    Get Quote
    TME FN9222EU-3-06 120
    • 1 -
    • 10 -
    • 100 -
    • 1000 $7.32
    • 10000 $7.32
    Get Quote
    Sager FN9222EU-3-06 1
    • 1 $7.3
    • 10 $7.3
    • 100 $6.72
    • 1000 $6.55
    • 10000 $6.11
    Buy Now

    TE Connectivity FN9222EU-3-06

    Iec Inlet Filter 250Vac, 3A, Faston, Earth Line Choke, Wide Flange Rohs Compliant: Yes |Schaffner Te Connectivity FN9222EU-3-06
    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Newark FN9222EU-3-06 Bulk 120
    • 1 $11.39
    • 10 $11.39
    • 100 $11.39
    • 1000 $11.06
    • 10000 $10.38
    Buy Now
    RS FN9222EU-3-06 Bulk 18 Weeks 120
    • 1 -
    • 10 -
    • 100 -
    • 1000 $9.21
    • 10000 $8.25
    Get Quote

    2EU30 Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    2EU30 Altech CIRCUIT BREAKER THERMAL MAGNETIC 2POLE 30A 277V Original PDF
    2EU30 Altech Over 600 obsolete distributor catalogs now available on the Datasheet Archive - Circuit Protection Devices Scan PDF

    2EU30 Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    rc 3866

    Abstract: abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE
    Text: MINIATURE CIRCUIT BREAKERS MCBs UL Recognized Supplementar y Pr otectors vs. UL Listed Manual Motor Contr ollers D4A D 16A I 277V AC 277V AC 10000 1D4.0 1DU16 I 10kA LISTED 4C87 UL Recognized UL Listed UL Recognized one pole supplementary protector UL Listed one pole manual motor controller


    Original
    1DU16 3P18U3H/6 3P18U3H/9 3P18U3H/12 3P18U3H/18 3P25U3H/6 3P25U3H/9 3P25U3H/12 3P25U3H/18 3P18U3H/24 rc 3866 abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE PDF

    shunt trip mccb

    Abstract: 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 ul508a 160A mccb curve iec 947-4-1 400v
    Text: Power Circuit of a UL508A Panel Typical UL508 Application Altech UL508 Disclaimer: This an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. Altech's V-EA UL508 Manual Motor Controllers


    Original
    UL508A UL508 UL508 E137938 LR104391 480Y/277V 50/60Hz shunt trip mccb 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 160A mccb curve iec 947-4-1 400v PDF

    mccb

    Abstract: 2EU30 mccb 3 pole 60A royal fuse time curves 1EU03 1EU05 1EU075 1EU10 1EU12 1EU125
    Text: E-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1E 2EN Application Examples: High efficiency motors, which have exceedingly high inrush currents. Relatively short thermal trip delays and very high magnetic trip points. Prototype testing is recommended.


    Original
    4x10-3 60/63A 100ms mccb 2EU30 mccb 3 pole 60A royal fuse time curves 1EU03 1EU05 1EU075 1EU10 1EU12 1EU125 PDF

    DIN 748-3

    Abstract: 7483 2DU10 1DU25 2DU5 501-2048 1DU10 2248 2249 A 2039 g 1DU05
    Text: Altech Corp. Circuit Protection Devices V-EA Circuit Breakers, DIN Rail Mount Continued “D” Characteristic Thermal one hour trip zone 1.13 to 1.45 times rated current (RC); magnetic 100 ms trip boundary 10 to 16 times RC. CENELEC high-inrush industrial. The “D” characteristic meets USA and Canadian


    Original
    application-2093 1GU03 1GU05 1GU08 2GU03 2GU05 2GU08 3GU03 3GU05 3GU08 DIN 748-3 7483 2DU10 1DU25 2DU5 501-2048 1DU10 2248 2249 A 2039 g 1DU05 PDF

    DIN 748-3

    Abstract: 7483
    Text: Altech Corp. Circuit Protection Devices V-EA Circuit Breakers, DIN Rail Mount Continued ÒDÓ Characteristic Thermal one hour trip zone 1.13 to 1.45 times rated current (RC); magnetic 100 ms trip boundary 10 to 16 times RC. CENELEC high-inrush industrial. The ÒDÓ characteristic meets USA and Canadian


    Original
    25-Up 25-Up 1DU03 2DU03 1GU03 2GU03 3GU03 DIN 748-3 7483 PDF

    mcb tripping curves

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE US 603U shunt trip mccb VDE0660 2CU8 230v ac to 12v dc without transformer circuit IEC 60947-2 IEC 947 EN60947 48V dc supply FROM 415VAC
    Text: Altech UL1077 Altech UL508 Altech UL489 2 Altech Corp. Expands Itʼs Circuit Breaker line! Altech Corporation, the US market leader in UL508 listed Manual Motor Controllers/Miniature Circuit Breakers, has expanded its circuit protection product line. Altechʼs established line of UL508 listed devices is now being complimented by UL1077


    Original
    UL1077 UL508 UL489 UL508 UL489 UL1077 3A/480Y/277V mcb tripping curves 60947-2 MAX EARTH LOOP IMPEDANCE US 603U shunt trip mccb VDE0660 2CU8 230v ac to 12v dc without transformer circuit IEC 60947-2 IEC 947 EN60947 48V dc supply FROM 415VAC PDF