Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    TURCK SWITCHING AMPLIFIER Search Results

    TURCK SWITCHING AMPLIFIER Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    TBAW56 Toshiba Electronic Devices & Storage Corporation Switching Diode, 80 V, 0.215 A, SOT23 Visit Toshiba Electronic Devices & Storage Corporation
    HN1D05FE Toshiba Electronic Devices & Storage Corporation Switching Diode, 400 V, 0.1 A, ES6 Visit Toshiba Electronic Devices & Storage Corporation
    TC75S102F Toshiba Electronic Devices & Storage Corporation Operational Amplifier, 1.5V to 5.5V, I/O Rail to Rail, IDD=0.27μA, SOT-25 Visit Toshiba Electronic Devices & Storage Corporation
    74HC4053FT Toshiba Electronic Devices & Storage Corporation CMOS Logic IC, SPDT(1:2)/Analog Multiplexer, TSSOP16B, -40 to 125 degC Visit Toshiba Electronic Devices & Storage Corporation
    LM1536H/883 Rochester Electronics LLC Operational Amplifier Visit Rochester Electronics LLC Buy

    TURCK SWITCHING AMPLIFIER Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    BI50-Q80-Y1X

    Abstract: PBT-GF30-V0
    Text: Subject to change without notice • Hans Turck GmbH & Co.KG 2002 • Edition: Hans Turck GmbH & Co.KG • Postfach • D-45466 Mülheim an der Ruhr • Telefon 02 08/49 52-0 • Telefax 02 08/49 52-264 Inductive sensor with extended switching distance


    Original
    D-45466 Bi50-Q80-Y1X PBT-GF30-V0 IM1-22Ex-R 230VAC BI50-Q80-Y1X PBT-GF30-V0 PDF

    Cu53 rtd

    Abstract: PT100 IEC 751
    Text: Temperature measuring amplifier 1-channel IM34-12Ex-CRi/K63 The temperature measuring amplifier IM34-12EX-CRI/K63 is designed to evaluate the temperature-dependent variations of resistance temperature detectors, thermoelements or low voltages and to output them as temperature-linear current signals between 0/4…20


    Original
    IM34-12Ex-CRi/K63 IM34-12EX-CRI/K63 PT100/NI100 Pt100 CU100 CuZn100 2013-07-13T20 D-45472 Cu53 rtd PT100 IEC 751 PDF

    Untitled

    Abstract: No abstract text available
    Text: Temperature measuring amplifier 1-channel IM34-14EX-CDRI The 1-channel Ex-temperature measuring amplifier IM34-14Ex-CDRi is designed to evaluate the temperature-dependent changes of Ni100/Pt100 resistors and thermocouples types B, E, J, K, L, N, R, S, T and to output


    Original
    IM34-14EX-CDRI IM34-14Ex-CDRi Ni100/Pt100 D-45472 2013-07-13T20 PDF

    PT100 Amplifier

    Abstract: No abstract text available
    Text: Ex-Temperature measuring amplifier 1-channel IM34-12EX-CRI The 1-channel Ex-temperature measuring amplifier IM34-12EX-CRI is designed to evaluate the temperature-dependent variations of resistance thermo detectors RTD Ni100/Pt100, thermoelement types B, E, J, K, L, N, R, S


    Original
    IM34-12EX-CRI IM34-12EX-CRI Ni100/Pt100, Ni100/Pt100 2013-07-13T20 D-45472 PT100 Amplifier PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451EX-T The 4-channel isolating switching amplifier IM1-451EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-451EX-T IM1-451EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R/K51 Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors. Three front panel switches are available to set the output mode separately for each channel (NO or NC mode), as well as to enable/disable wire-break (WB) and short-circuit (SC)


    Original
    IM1-22EX-R/K51 D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R The dual-channel isolating switching amplifier IM1-22EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-R IM1-22EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM12-22EX-R The dual-channel isolating switching amplifier IM12-22EX-R is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM12-22EX-R IM12-22EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451EX-R The 4-channel isolating switching amplifier IM1-451EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-451EX-R IM1-451EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-121EX-R The single-channel isolating switching amplifier IM1-121EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-121EX-R IM1-121EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-12EX-MT The single-channel isolating switching amplifier IM1-12EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-12EX-MT IM1-12EX-R D-45472 2013-07-13T20 PDF

    Im1-12ex-t

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-12EX-T The 1-channel isolating switching amplifier IM1-12EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-12EX-T IM1-12EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-T The dual-channel isolating switching amplifier IM1-22EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-T IM1-22EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 1-channel IM1-121EX-T The single-channel isolating switching amplifier IM1-121EX-T is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-121EX-T IM1-121EX-T D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-231EX-R The dual channel isolating switching amplifier IM1-231EX-R is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-231EX-R IM1-231EX-R D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-MT The dual channel isolating switching amplifier IM1-22EX-MT is equipped with an intrinsically safe input circuit. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-MT IM1-22EX-MT D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22-R 2-channel IM1-22-R isolating switching amplifier The output circuits feature 2 relays, each with one NO contact. Six front panel switches are available to set the output mode separately for each channel NO/NC mode , as well as to enable/disable


    Original
    IM1-22-R IM1-22-R 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451-R Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the 4-channel isolating transducer IM1-451R. When using mechanical contacts, the wirebreak and short-circuit monitoring must be


    Original
    IM1-451-R IM1-451R. 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Inductive sensor ring sensor NI65R-S32SR-VP44X • Rectangular, height 32 mm ■ Plastic, ABS ■ Static output performance ■ Sensitivity adjustable via potentiometer ■ Modular design, ring probe and switching amplifier also separately mountable ■ Output pulse length min. 100 ms


    Original
    NI65R-S32SR-VP44X 2013-07-13T04 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 4-channel IM1-451-T Sensors according to EN 60947-5-6 NAMUR or potential-free contactors can be connected to the 4-channel isolating transducer IM1-451T. When using mechanical contacts, the wirebreak and short-circuit monitoring must be


    Original
    IM1-451-T IM1-451T. D-45472 2013-07-13T20 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IMC-DI-22EX-PNC/24VDC The 2-channel isolating switching amplifier IMC-DI-22EX-PNC/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free


    Original
    IMC-DI-22EX-PNC/24VDC IMC-DI-22EX-PNC/24VDC 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IMC-Di-22Ex-PNO/24VDC The 2-channel isolating switching amplifier IMC-Di-22Ex-PNO/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR , variable resistances or potential-free


    Original
    IMC-Di-22Ex-PNO/24VDC IMC-Di-22Ex-PNO/24VDC 2013-07-13T20 D-45472 PDF

    Untitled

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R/230VAC • ■ ■ ■ Application area acc. to ATEX: II 1 G; II (1) D Signal flow direction adjustable (NO/ NC) Input circuits monitored for wire-break/ short-circuit (ON/OFF switchable) Removable terminal blocks


    Original
    IM1-22EX-R/230VAC 2013-07-13T20 D-45472 PDF

    IM1-22EX-R/24VDC

    Abstract: No abstract text available
    Text: Isolating switching amplifier 2-channel IM1-22EX-R/24VDC The dual-channel isolating switching amplifier IM1-22EX-R/24VDC is equipped with intrinsically safe input circuits. Sensors according to EN 60947-5-6 NAMUR can be connected to the device or potential-free contactors.


    Original
    IM1-22EX-R/24VDC IM1-22EX-R/24VDC D-45472 2013-07-13T20 PDF