DUB02
Abstract: SPDT relay 270104
Text: Monitoring Relays 1-Phase True RMS AC Over/Under Voltage Types DUB02, PUB02 DUB02 • TRMS AC over/under voltage monitoring relays • Measuring if power supply is within set limits • Measure on own power supply • Measuring ranges: 24, 115, 230 VAC • Power ON delay 1 or 6 s selectable by DIP-switch
|
Original
|
PDF
|
DUB02,
PUB02
DUB02
DUB02)
PUB02)
DUB02
SPDT relay
270104
|
electromagnetic relay
Abstract: relay 24 volt DUB03
Text: Monitoring Relays 1-Phase True RMS AC/DC Over or Under Voltage Types DUB03, PUB03 • TRMS AC/DC over or under voltage monitoring relays • Selection of measuring range by DIP-switches • Adjustable voltage on relative scale • Adjustable hysteresis on relative scale
|
Original
|
PDF
|
DUB03,
PUB03
DUB03)
PUB03)
DUB03
DUB03
PUB03
electromagnetic relay
relay 24 volt
|
PT250 RTD
Abstract: BQ HSX PT250 table Pt100-250-500-1000 UDM35DS PT1000 table npn 1000V 100a PT100 IEC B pt100/PT100 PT1000 CONVERSION TABLE
Text: Digital Panel Meters Modular Indicator and Controller Type UDM35 • • • • • • • • • • • Multi-input modular instrument 3 1/2 dgt LED 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements: selectable full scales
|
Original
|
PDF
|
UDM35
200mV
Pt100-250-500-1000,
Ni100,
20mA/10VDC
RS485
RS232
pan48mm
UDM35DS
PT250 RTD
BQ HSX
PT250 table
Pt100-250-500-1000
PT1000 table
npn 1000V 100a
PT100 IEC B
pt100/PT100
PT1000 CONVERSION TABLE
|
Untitled
Abstract: No abstract text available
Text: Data Sheet AM-160-A Precision TRMS Digital Multimeters with PC Connection These TRMS Commercial grade digital multimeters offer more features, better accuracy at a great price. TRMS, accuracy to 0.02%, frequency, capacitance, duty cycle, temperature, analog
|
Original
|
PDF
|
AM-160-A
TPK-59
MTL-90B
AM-160-A
877-AMPROBE
|
Untitled
Abstract: No abstract text available
Text: Data Sheet AC68C TRMS Clamp Type Digital Multimeter No hassle warranty No waiting. No shipping charges. Our commitment to high-quality products and customer service is demonstrated by our industry exclusive “No Hassle” warranty. In the unlikely event that an Amprobe Test
|
Original
|
PDF
|
AC68C
4000-count
functions/11
DC/750
877-AMPROBE
|
Untitled
Abstract: No abstract text available
Text: Data Sheet AM-270 TRMS Industrial Multimeter A commercial - industrial multimeter for Electrical and HVAC applications dedicated for electrical and HVAC professionals. Safety rated to CAT IV 600V and CAT III 1000V for outdoor and indoor applications requiring direct connection to main panel of
|
Original
|
PDF
|
AM-270
AM-270
877-AMPROBE
300mV
125kHz
20kHz
|
phoenix contact MCR R I 4v
Abstract: phoenix contact "MCR R I 4v" mcr-vac-ui-0-dc phoenix contact MCR
Text: Voltage Measuring Transducer for AC Voltage MCR-VAC-UI-0-DC 1. Description • 3-way electrical isolation • TRMS measurement • Adjustable voltage ranges • ZERO/SPAN adjustment ±20% Voltage transducers measure AC voltages in several signal ranges from 0…24 V AC to 0…370 V AC and
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.21 and CM-MPS.41 Characteristics –– Monitoring of three-phase mains for phase sequence can be switched off , phase failure, over- and undervoltage as well as phase unbalance –– TRMS measuring principle
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: ACD-16 Pro & ACD-16 TRMS Pro 1000A Data-Logging Clamp-on Multimeters CAT TRUE 600V ACD-16 TRMS Pro R M S z Need the perfect tool to troubleshoot a system? The ACD-16’s provide a full range of measurements, enhanced with data logging capabilities, to catch what
|
Original
|
PDF
|
ACD-16
ACD-16â
RS-232
|
PSW1C 25
Abstract: DT009A
Text: ECO-PACTM 1 Single Phase AC Controller Modules PSW1C25 TRMS VRRM = 26 A = 600-1600 V Preliminary Data Sheet VRSM VRRM Type VDSM VDRM V (V) 700 600 PSW1C 25/06 900 800 PSW1C 25/08 1300 1200 PSW1C 25/12 IJ H G EF AB Symbol I TRMS ITAVM ITAVM ITSM ∫ i2 dt
|
Original
|
PDF
|
PSW1C25
PSW1C 25
DT009A
|
IEC 68-2-32
Abstract: No abstract text available
Text: data loggers Simple Logger II TRMS Clamp-On Current Special product features RE C 6 C uc T TO 00 AA to 55 for New Pr UT E B TO N ' O PE N ' O p. DS U P OR N 51 Designed for plant and field service applications and for use in harsh environments od
|
Original
|
PDF
|
50/60Hz)
CL601
600Aac
600Aac,
IEC 68-2-32
|
Untitled
Abstract: No abstract text available
Text: Monitoring Relays 1-Phase True RMS AC/DC Over or Under Voltage Types DUB01, PUB01 DUB01 • TRMS AC/DC over or under voltage monitoring relays • Selection of measuring range by DIP-switches • Measuring ranges from 0.1 to 500 V AC/DC • Adjustable voltage on relative scale
|
Original
|
PDF
|
DUB01,
PUB01
DUB01
DUB01)
PUB01)
|
Untitled
Abstract: No abstract text available
Text: Digital Panel Meters Modular Indicator and Controller Type USC-DIN • • • • • • • • Multi-input modular signal’s conditioner 0.1% RDG basic accuracy TRMS AC current and voltage measurements AC/DC current measurements; selectable full scales
|
Original
|
PDF
|
200mV
Pt100-250-500-1000,
Ni100,
001Hz
50kHz)
20mA/10VDC
RS485
RS232
RS232
|
Untitled
Abstract: No abstract text available
Text: Digital Panel Meters AC Ammeters and Voltmeters Type LDM30 AV1/AV5 • 3 dgt LED + dummy zero, µ-based digital indicator, for TRMS AC current and voltage measurements • Dip-switch-selectable ranges • Front dimensions: 48 x 96 mm • Front protection degree: IP 50 IP 65 on request
|
Original
|
PDF
|
LDM30
230VAC
500mA
115VAC
48VAC
LDM30DS
24VAC
|
|
spdt relays
Abstract: SPDT relay 6 Volt 9 Volt DPDT Relay voltage monitoring relay RH 25 RE2
Text: Monitoring Relays 1-Phase True RMS AC/DC Over and Under Voltage Types DUC01, PUC01 DUC01 • TRMS AC/DC over+under, over+over or under+under voltage monitoring relays • Selection of measuring range by DIP-switches • Measuring ranges from 2 to 500 V AC/DC
|
Original
|
PDF
|
DUC01,
PUC01
DUC01
DUC01)
PUC01)
DUC01
spdt relays
SPDT relay 6 Volt
9 Volt DPDT Relay
voltage monitoring relay
RH 25 RE2
|
Terpene Defluxer
Abstract: No abstract text available
Text: Anti-Sulfurated Thick Film Chip Resistors RMS series standard Halogen-Free Document No. TRMS-XX0S001G Revise Date 2014/05/09 page number 1/13 1. Scope : This specification applies for the RMS series of Anti-Sulfurated thick film chip resistors made by TA-I.
|
Original
|
PDF
|
TRMS-XX0S001G
1/16W
1/10W
12-120eries
Terpene Defluxer
|
Untitled
Abstract: No abstract text available
Text: Monitoring Relays 1-Phase True RMS AC/DC Over or Under Voltage Types DUB01, PUB01 DUB01 • TRMS AC/DC over or under voltage monitoring relays • Selection of measuring range by DIP-switches • Measuring ranges from 0.1 to 500 V AC/DC • Adjustable voltage on relative scale
|
Original
|
PDF
|
DUB01,
PUB01
DUB01
DUB01)
PUB01)
DUB01
PUB01
|
Terpene Defluxer
Abstract: No abstract text available
Text: Anti-Sulfurated Thick Film Chip Resistors RMS series standard Halogen-Free Document No. TRMS-XX0S001E Revise Date 2013/05/15 page number 1/12 1. Scope : This specification applies for the RMS series of Anti-Sulfurated thick film chip resistors made by TA-I.
|
Original
|
PDF
|
TRMS-XX0S001E
1/16W
1/10W
12-120ribed
Terpene Defluxer
|
PPB01CM48
Abstract: DPB01CM23 PPB01 DPB01CM48 star delta wiring diagram DPB01 phase failure relay 3 phase monitoring relays loss of neutral monitor marking L2 diode
Text: Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multi-function Types DPB01, PPB01 DPB01 • TRMS 3-phase over and under voltage, phase sequence and phase loss monitoring relays • Detect when all 3 phases are present and have the correct phase sequence except for DPB01.N and
|
Original
|
PDF
|
DPB01,
PPB01
DPB01
DPB01.
PPB01.
DPB01)
PPB01)
PPB01CM48
DPB01CM23
PPB01
DPB01CM48
star delta wiring diagram
DPB01
phase failure relay
3 phase monitoring relays
loss of neutral monitor
marking L2 diode
|
Untitled
Abstract: No abstract text available
Text: □IX Y S VW 2x60 AC Controller Modules 2 x 60 A 800-1600 V ^RMS VRRM 1 2 5 4 Type 800 800 1200 1200 1400 1600 1400 1600 VW2x60-08io1 VW2x60-12io1 VW2x60-14io1 VW2x60-16io1 Symbol Test Conditions U T c = 85°C, 50 - 400 Hz per phase ms ^TRMS ^TAVM ^TSM l2t
|
OCR Scan
|
PDF
|
VW2x60-08io1
VW2x60-12io1
VW2x60-14io1
VW2x60-16io1
|
Untitled
Abstract: No abstract text available
Text: □ IXYS MCC60 Thyristor Module TRMS •TAVM V RRM, DRM Preliminary data V RSM V RRM V DSM V DRM V V 1700 1600 Conditions I t RMS j I f r m s T vj - T Vjm T c = 85°C ; 180° sine I t SM! I f SM l2dt T vj = T Vjm V R= 0 t = 10 ms 50 Hz , sine t = 8.3 ms (60 Hz), sine
|
OCR Scan
|
PDF
|
MCC60
O-240
2x100
60-16io1
|
MCC44-12IO1B
Abstract: io1B mcc94-22io1b MCC56-08IO8B MCC56-12IO8B MCC95-14IO1B MCC95-12io1B MCC26-14IO1 MCC26 MCC56-16IO1B
Text: j Thyristor/Thyristor Modules lTAV = 18-116 A Type M CC .io1B v v RRM 1 TAV M CC.io8B p T c ^TRMS *TSM A 45°C 10 ms A V DRM rr "^ VJM ^ th J C Package style thCH per Chip per Chip o z d> V A MCC19-08io1B MCC19-12io1B MCC19-14io1B MCC19-16io1B 800 1200
|
OCR Scan
|
PDF
|
MCC19-08io1B
MCC19-12io1B
MCC19-14io1B
MCC19-16io1B
MCC19-08io8B
MCC19-12io8B
MCC19-14io8B
MCC19-16io8B
MCC21-14io8B
MCC21-16io8B
MCC44-12IO1B
io1B
mcc94-22io1b
MCC56-08IO8B
MCC56-12IO8B
MCC95-14IO1B
MCC95-12io1B
MCC26-14IO1
MCC26
MCC56-16IO1B
|
DIN41814
Abstract: DIN41814-151A4
Text: y T158S 200* 400 Elektrische Eigenschaften Electrical properties Höchstzulässige Werte Udrm , U rrm Periodische Vorwärts- und Rückwärts-Spitzensperrspannung Effektiver Durchlaßstrom I trmsm Dauergrenzstrom Itavm Maximum permissible values repetitive peak forward off-state
|
OCR Scan
|
PDF
|
T158S
-40oC.
DIN41814â
151A4
DIN41814
DIN41814-151A4
|
MC045
Abstract: MC0450 LT 1385
Text: I1 !|fil:i|P!!i|l!E'llll:jlîi ìli!’!! ill High Power Single Thyristor Module MC0450 VRRM = 2000 - 2200 V = 450 A TRMS = 464 A "TAV Prelim inary Data V RSM V RRM v DSM v DRM V V 2100 2000 2200 2300 Symbol Itrm s Itav Itsm Pt 15000 16000 A A Tyj V r = o
|
OCR Scan
|
PDF
|
MC0450
UL758,
MC0450
M8x16,
flb22b
MC045
LT 1385
|