Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    SPAZC21 Search Results

    SPAZC21 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    spam 150

    Abstract: 4d34 SPCJ 4D34 SPAJ 120 SPCJ 4D29 SPTU 240 wiring diagram of spcj 4d29 relay SPAJ 140 wiring diagram for abb spaj 140 C SPAJ 120 c
    Text: SPAM 150 C Motor protection relay User´s manual and Technical description 3I >> 3 2 I I n = 1A 5A (I o ) I n = 1A 5A f n = 50Hz I 5 L1 I L2 I L3 I I o IRF 60Hz SPAM 150 C 80.265V – ~ 18.80V – NO NC I θ /I n t 6x [ s] p [ %] θ a [ %] θ i [ %]


    Original
    PDF 750637-MUM FIN-65101 spam 150 4d34 SPCJ 4D34 SPAJ 120 SPCJ 4D29 SPTU 240 wiring diagram of spcj 4d29 relay SPAJ 140 wiring diagram for abb spaj 140 C SPAJ 120 c

    SPCJ 4D29

    Abstract: SPTU 240 SPAJ 120 abb spaj RELAY SPAJ 120 c 4D29 SPAJ 140 IRF 9710 SPAJ160C ABB SPAJ 120
    Text: SPAJ 160 C Capacitor protection relay User´s manual and Technical description 3I > ∆I 3I < 2 I n = 1A I n = 1A f n = 50Hz 5A I 5A (∆I ) I 5 60Hz L1 I L2 I L3 ∆I c IRF SPAJ 160 C 80.265V – ~ 18.80V – RESET STEP I b >/I n U aux k SPCJ 4D40


    Original
    PDF 750064-MUM FIN-65101 SPCJ 4D29 SPTU 240 SPAJ 120 abb spaj RELAY SPAJ 120 c 4D29 SPAJ 140 IRF 9710 SPAJ160C ABB SPAJ 120

    abb fox 20

    Abstract: abb fox 6 REL 551 abb "fox 6 plus" SMS 010 506 003-BEN SPA-ZC21 480-AA 005-BEN 232-C
    Text: ~ction pervision munication vith REL 551 * 1.2 1MRK Line differE~ntial protection OOS-BEN Page 1 terminal November 1997 Changed since October Data subject to change 1997 without nariGe ABB Network Partner SE 95 02 13 Features .Phase segregateclline differential protection


    Original
    PDF 078-AA 876-KA 76-0A V35/36 001-BEN) 003-BEN 005-UEN 005-REN 014-BEN 034-BEN abb fox 20 abb fox 6 REL 551 abb "fox 6 plus" SMS 010 506 003-BEN SPA-ZC21 480-AA 005-BEN 232-C

    rel 511

    Abstract: Broken Conductor Detection for Overhead Line Distribution System rel 511 1.2 microcontroller based substation monitoring and c SPA-ZC21 002-BEN microcontroller based substation monitoring using O-50 SP10 REL511
    Text: REL 511 * 1.2 1 MR~ 506 002-BEN Line distance protection terminal ~ Page 1 November 1 7 Changed si October 1997 Dala subject Ichange wilhoul nolice ABB Network Partner SE 95 02 08 - Features .Simultaneous measurement of the different phase-phase and ph ase-earth loop impedances


    Original
    PDF 002-BEN 003-BEN 002-REN 030-BEN 029-BEN 002-UEN 509012-BEN 014-BEN 034-BEN rel 511 Broken Conductor Detection for Overhead Line Distribution System rel 511 1.2 microcontroller based substation monitoring and c SPA-ZC21 002-BEN microcontroller based substation monitoring using O-50 SP10 REL511

    S202 TO2

    Abstract: SCHEMATIC DIAGRAM REVERSE KWH METER SPCJ 4D29 IDMT relay SPA-ZC21 9pin d type Female PCB connector ABB breaker S5 SPA-ZC17 MARKING 4F7 IDMT OVERCURRENT relay
    Text: SPAC 335 C and SPAC 336 C Feeder terminals User´s manual and Technical description B O fn = 50 60 Hz I n= 1 I n= 1 U n = 100 / 5 / 5 / 110 A I A( I o ) V(U o ) 2I > I I 2 SPAC 335 C I IRF 5 L1 I L3 U o I o IRF TEST INTERLOCK I >/I n GAS PRESSURE STEP MOTOR VOLTAGE


    Original
    PDF 750122-MUM FIN-65101 S202 TO2 SCHEMATIC DIAGRAM REVERSE KWH METER SPCJ 4D29 IDMT relay SPA-ZC21 9pin d type Female PCB connector ABB breaker S5 SPA-ZC17 MARKING 4F7 IDMT OVERCURRENT relay

    REL 521

    Abstract: 506 003-BEN rel 521 1.2 O-50 microcontroller based substation monitoring and c rel 511 266AA microcontroller based substation monitoring using with parameters 003-UEN 376AA
    Text: REL 521 * 1.2 Line distance protection 1 MAK 506 003-BEN terminal Page 1 .\.- .~.a'.~. .~~, Changed since Oclober 1997 Data subject lo change wilhoul nolice ABB Network Partner SEgS 02 16 ~ Features .Simultaneous measurement of the phasephase and ph ase-earth loop impedances within


    Original
    PDF 003-BEN 003-UEN 003-REN 014-BEN 034-BEN REL 521 506 003-BEN rel 521 1.2 O-50 microcontroller based substation monitoring and c rel 511 266AA microcontroller based substation monitoring using with parameters 003-UEN 376AA

    REL 561

    Abstract: abb fox 6 abb fox 20 SPA-ZC21 under ground cable fault distance locator ael 1200 abb "fox 6 plus" English Electric relay cage RK795 232-C
    Text: - REL 561 * 1.2 Line differential 1MRK 506 006-BEN Pan" 1 November 1997 Changed since October 1997 Dala subjecI lo change without nolice protec:tion terminal ABB Network Partner SE 95 02 12 Features .Phase segregated line differential protection .Current differential measurement evaluating


    Original
    PDF 006-BEN 295-CA 295-DA 078-AA 876-KA 876-EA 003-BEN 006-REN 1MRK511014-BEN 034-BEN REL 561 abb fox 6 abb fox 20 SPA-ZC21 under ground cable fault distance locator ael 1200 abb "fox 6 plus" English Electric relay cage RK795 232-C

    Broken Conductor Detection for Overhead Line Distribution System

    Abstract: ABB media converter rel 511 1.2 001-BEN 40 MVA transformer rel 511 pg 3ab microcontroller relay change fuse power system microcontroller based substation monitoring and c ZC 22
    Text: REL 501 * 1.2 1MRKISO6 0O1-BEN Line distance protection terminal ~ Page 1 November 199 Changed since Data subject lo ctober 1997 ange wilhout nolice ABB Network Partner SE950207 Features .Simultaneous measurement of the different phase-phase loop impedances within the


    Original
    PDF SE950207) 003-BEN 001-UEN 001-REN 029-BEIN 012-BEN 22EN1A 014-BEN 034-BEN Broken Conductor Detection for Overhead Line Distribution System ABB media converter rel 511 1.2 001-BEN 40 MVA transformer rel 511 pg 3ab microcontroller relay change fuse power system microcontroller based substation monitoring and c ZC 22

    lockout relay

    Abstract: 3 pole circuit breaker ABB REB 551 digital testing of high voltage circuit breaker SPA-ZC21 circuit breaker abb 1 pole 001-BEN Synchronism check relay 034-BEN 007-AA
    Text: A l l l i REB 551 * 1.2 Breaker protection terminal • , 1MRK 505 001-BEN ■- Changed since October 1997 Data subject to change without notice ABB Network Partner SE950214 Features • Breaker related protection and associated func­ tions in a numerical unit


    OCR Scan
    PDF 11MRK 001-BEN 1MKC980 020-BS 1MRK505 001-UEN 007-AA 314-EB 077-DB 078-AA lockout relay 3 pole circuit breaker ABB REB 551 digital testing of high voltage circuit breaker SPA-ZC21 circuit breaker abb 1 pole Synchronism check relay 034-BEN

    SPA-ZC21

    Abstract: REL100 indactic 65 RET316 abb rk 216 REL316 LB 1639 dcf77 receiver SPAZC21 ABB RET 316 1MDB04004-EN
    Text: “ *7 Type SMS 010 * Station Monitoring System —— t - — rr~ 1MDB11019-EN Page 1 September 1993 Data subject to change without notice • New ABB Network Control & Protection Features Application • Provides on-request information from pro* tective relays comprising


    OCR Scan
    PDF 1MDB11019-EN SPA-ZC20 1MDB11010-EN SPA-ZC17 DCF-77 R0001 R0002 RCRA100 1000M SPA-ZC21 REL100 indactic 65 RET316 abb rk 216 REL316 LB 1639 dcf77 receiver SPAZC21 ABB RET 316 1MDB04004-EN