    Part ECAD Model Manufacturer Description Download Buy
    ISO7021D Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments
    ISO7021FD Texas Instruments Ultra-low power, ATEX/IECEx-certified, two-channel digital isolator 8-SOIC -55 to 125 Visit Texas Instruments

    PTB 98 ATEX Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    IEC 60947-5-1 limit switch ex d

    Abstract: switch limit A05VV-F 2A1004 01ATEX DC-13 H05vv-F 0.75 limit switch limit switch code
    Text: Insert switch/limit switch Certification Insert switch Limit switch PTB 98 ATEX 1032 U PTB 00 ATEX 1093 X IBExU 01 ATEX 1007 X Ambient temperature -20 °C to +40 °C -55 °C to +75 °C -20 °C to +75 °C for dust Ex -55 °C on request Limit switch EEx d insert switch/limit switch


    Original
    AC-15 DC-13 03-0330-0154-06/03-BCS-A129306E IEC 60947-5-1 limit switch ex d switch limit A05VV-F 2A1004 01ATEX DC-13 H05vv-F 0.75 limit switch limit switch code PDF

    CEAG PTB 00 ATEX 1040

    Abstract: PTB-No. Ex-86.B.1021 PTB 98 ATEX 3121 Ex-87 PTB 99 ATEX 3121 B 1038 PTB 99 ATEX EX-88 1037U CEAG
    Text: Technical data Dimensions in mm 85 75 115 115 35 64 55 85 52 85 85 75 52 Switch/Pushbutton Ex-installation switches and Ex-pushbuttons Marking to 94/9/EC II 2 G/ II 2 D* Type of protection EEx de IIC T6 EC-Type Examination Certificate PTB 98 ATEX 3121 Made of a low temperature impact-resistant


    Original
    94/9/EC CEAG PTB 00 ATEX 1040 PTB-No. Ex-86.B.1021 PTB 98 ATEX 3121 Ex-87 PTB 99 ATEX 3121 B 1038 PTB 99 ATEX EX-88 1037U CEAG PDF

    Bosch CJ 840

    Abstract: PD-53 burkert ac10 burkert EX-95 CE0102 CEO102 2129X 2043X bosch me 7.3.1
    Text: Operating Instructions Bedienungsanleitung Instructions de Service PTB No. 00 ATEX 2129 X Device with II 2G/D EEx m and II 2G EEx em-approval Example: Type 6013 Geräte mit II 2G/D EEx m bzw. II 2G EEx em-Zulassung Beispiel: Type 6013 Appareils avec mode de protection


    Original
    94/9/EC Ex-95 2043X Bosch CJ 840 PD-53 burkert ac10 burkert CE0102 CEO102 2129X 2043X bosch me 7.3.1 PDF

    PTB 00 ATEX 3117

    Abstract: PTB No. Ex-87.B.2016U PTB 99 ATEX 3117 ATEX 3117 PTB 99 ATEX 1007U Power cable 25mm2 EX-88 GHG43 n608 LM 3117
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0601-3 Name: N-601 100: DATE: JAN 19 2006 Time: 5:37:08 PM Operator: RB COLOR: CMYK UL/cUL listed Cl. I, Div. 2, Groups A, B, C, D Cl. I, Zones 1 and 2, A Ex de IIB + H2 T6 Cl. II, Div. 1, Groups E, F, G (cUL)


    Original
    SYS19: CRMAIN06-0601-3 N-601 66008com CRMAIN06-0610-1 N-610 PTB 00 ATEX 3117 PTB No. Ex-87.B.2016U PTB 99 ATEX 3117 ATEX 3117 PTB 99 ATEX 1007U Power cable 25mm2 EX-88 GHG43 n608 LM 3117 PDF

    radox 125

    Abstract: Bartec radox 155 H05V2-K ptb 98 atex A129-30 limit switch radox Bartec 07 radox 125 0,25
    Text: Miniature insert switch/limit switch Miniature Description BARTEC miniature switches are used in areas with of limited space for a flameproof switching element. They are especially suitable for applications in valves, thermostats, push switches, servo components,


    Original
    03-0330-0156-11/05-BCS-A129308E A129308 radox 125 Bartec radox 155 H05V2-K ptb 98 atex A129-30 limit switch radox Bartec 07 radox 125 0,25 PDF

    GHG 744

    Abstract: jb 5531 marshalling box ghg 745 744 745 510 terminal EEx "e" II - T6 ghg junction box GHG 44 ATEX BOX in 746
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-0159-2 Name: 6F-159 100: DATE: JAN 19 2006 Time: 5:06:20 PM Operator: JB COLOR: CMYK TCP: 15001 Typedriver Name: TS name csm no.: 100 UL/cUL Listed EEx de IIC, T6, Zones 1 and 2 Class I, Division 2, Groups A, B, C, D


    Original
    SYS19: CRMAIN06-0159-2 6F-159 66008com GHG 744 jb 5531 marshalling box ghg 745 744 745 510 terminal EEx "e" II - T6 ghg junction box GHG 44 ATEX BOX in 746 PDF

    Bartec bi924s

    Abstract: DX910S SA920S BI914S TU921N TU921 Bartec CI920N BP910S SA910N
    Text: IndustrialIT System 800xA S900 Remote I/O System Data Sheet Features and Benefits „ Distributed I/O system for zone 1 and zone 2 applications „ Modular design, with hot-pluggable modules „ Redundancy in power supply and communication interface „ HART pass through, access to


    Original
    800xA 3BDD010420R0601 Bartec bi924s DX910S SA920S BI914S TU921N TU921 Bartec CI920N BP910S SA910N PDF

    abb ts202

    Abstract: SENSORS TEMPERATURE Pt-100-DIN 43760 dmt 90 atex g 001 DMT 02 ATEX F 001 atex 2035 EC certificate PTB ATEX 1144 X prometer PTB 01 ATEX 2035 PTB 2035 X pt 100 temperature sensor RTD abb
    Text: FieldIT Data Sheet 10/11-8.62 EN Field mounted Temperature Transmitter TS202/TS202-Ex programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TS202/TS202-Ex abb ts202 SENSORS TEMPERATURE Pt-100-DIN 43760 dmt 90 atex g 001 DMT 02 ATEX F 001 atex 2035 EC certificate PTB ATEX 1144 X prometer PTB 01 ATEX 2035 PTB 2035 X pt 100 temperature sensor RTD abb PDF

    PTB 00 ATEX 3117

    Abstract: CEAG PTB 00 ATEX 3117 ceag ghg atex ceag ghg 411 ceag ghg 412 GHG 412 PTB 99 ATEX CEAG P413 CEAG PTB 00 ATEX 1040 ATEX 3117
    Text: Betriebsanleitung Explosionsgeschützte Steuergeräte GHG 411 und GHG 412 Operating instructions Explosion-protected control units GHG 411 and GHG 412 Mode d’emploi Boites de commande GHG 411 et GHG 412 pour atmosphères explosives GHG 410 7001 P0001 D/E/F I


    Original
    P0001 PTB 00 ATEX 3117 CEAG PTB 00 ATEX 3117 ceag ghg atex ceag ghg 411 ceag ghg 412 GHG 412 PTB 99 ATEX CEAG P413 CEAG PTB 00 ATEX 1040 ATEX 3117 PDF

    pt100 rtd rosemount

    Abstract: pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102
    Text: FieldIT Data Sheet 10/11 8.54 EN Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TH102/TH102-Ex pt100 rtd rosemount pt 100 temperature sensor RTD abb PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd rosemount PT-1000 sensor PT-100 RTD 3 wire sensor - rosemount PT-100 RTD 3 wire sensor rosemount PT100 rosemount PT-100 RTD 4 wire sensor rosemount th102 PDF

    rosemount 1144

    Abstract: rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor
    Text: FieldIT Data Sheet 10/11 8.64 EN Temperature Transmitter, field mounted TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TH202/TH202-Ex rosemount 1144 rosemount pt 100 rtd V11523 pt100 rtd rosemount PT100 rosemount EC certificate PTB ATEX 1144 X Thermocouple Type L namur NE 43 rosemount PT 441 rosemount PT-1000 sensor PDF

    th202

    Abstract: ABB Hart Temperature Transmitter TH202 TH202-Ex 3KDE115040R4501 tag 8530 pt 100 temperature sensor RTD abb NGV220-EX agsfd V11523 fuse terminal EEx "e" II - T6
    Text: Data Sheet 10/11-8.64 EN Field mounted Temperature Transmitter TH202/TH202-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TH202/TH202-Ex th202 ABB Hart Temperature Transmitter TH202 TH202-Ex 3KDE115040R4501 tag 8530 pt 100 temperature sensor RTD abb NGV220-EX agsfd V11523 fuse terminal EEx "e" II - T6 PDF

    ceag ghg 122 3121

    Abstract: ceag ghg 534 ceag ghg 534 2506 crouse-hinds GHG 960 663 B0708 CEAG PTB 00 ATEX 3108 ceag ghg 412 ceag ghg 543 ceag GHG 543 2306 Ex-92
    Text: C A T A L O G U E E X P L O S I O N P R O T E C T E D 3 1 0 P R O D U C T S The CEAG Sicherheitstechnik GmbH factory in Eberbach, Germany The CEAG Nortem SA Barcelona, Spain The factory in Sheerness, UK CEAG SICHERHEITSTECHNIK GMBH Essentials, Innovations and a few words about your money


    Original
    ambitious531 03/SL D-69412 ceag ghg 122 3121 ceag ghg 534 ceag ghg 534 2506 crouse-hinds GHG 960 663 B0708 CEAG PTB 00 ATEX 3108 ceag ghg 412 ceag ghg 543 ceag GHG 543 2306 Ex-92 PDF

    SENSORS TEMPERATURE Pt-100-DIN 43760

    Abstract: PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature pt 100 temperature sensor abb ptb 99 atex 2123
    Text: FieldIT Data Sheet 10/11-8.50 EN Rail mounted Temperature Transmitter TS102/TS102-Ex programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TS102/TS102-Ex SENSORS TEMPERATURE Pt-100-DIN 43760 PTB 01 ATEX 2035 TS102 TS102-EX atex 2123 pt 100 temperature sensor RTD abb Pt 100 sensor connection PT-100 temperature pt 100 temperature sensor abb ptb 99 atex 2123 PDF

    ceag ghg

    Abstract: PTB 98 ATEX 3121 GHG273 ceag ghg atex 2732000R0003 R0018 R0003 ceag ghg 273 4000 R0017 ceag ghg atex 273 r0018
    Text: Z O N E 1 Z O N E 2 E X - I N S T A L L A T I O N Z O N E 21 U N I T S A N D Z O N E 22 M A T E R I A L Switch/Pushbutton E X - I N S T A L L A T I O N I 85 75 Ex-installation switches and Ex-pushbuttons Ex-installation switches and Ex-pushbuttons II 2 G ⎮


    Original
    R0017 R0018 R0003 R0004 R0011 94/9/EC ceag ghg PTB 98 ATEX 3121 GHG273 ceag ghg atex 2732000R0003 R0018 R0003 ceag ghg 273 4000 R0017 ceag ghg atex 273 r0018 PDF

    Untitled

    Abstract: No abstract text available
    Text: HAZARDOUS LOCATION SWITCHES 14CE100 Series Miniature Enclosed, Explosion Proof X ATEoved Switches r p p a The 14CE100 Series has been designed for use in explosive environments. It is approved to meet the requirements of the Low Voltage directive and is CE marked. The prewired construction allows


    Original
    14CE100 CE102-12 14CE102-15 14CE118-1 14CE118-6 14CE118-10 14CE103-1 14CE103-3 PDF

    AI41EX

    Abstract: No abstract text available
    Text: Remote I/O system excom input module, analog, passive, 4-channel AI41EX The input module AI41Ex is designed to connect 4-wire transducers active input = sink mode / transducer active . The resolution is 14 bit, i.e. the analogue value between 0…21 mA is represented as a


    Original
    AI41EX AI41Ex 2013-07-13T19 D-45472 PDF

    contrans ts 11

    Abstract: pt 100 temperature sensor RTD abb contrans ts 02 abb ts02 TS02-ex MEssumformer TS-02 th02 ptb 99 atex 2123 declaration Contrans ts02 PT100 IEC 751
    Text: FieldIT Data Sheet 10/11-8.17 EN Head mounted Temperature Transmitter TS02/TS02-Ex programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TS02/TS02-Ex contrans ts 11 pt 100 temperature sensor RTD abb contrans ts 02 abb ts02 TS02-ex MEssumformer TS-02 th02 ptb 99 atex 2123 declaration Contrans ts02 PT100 IEC 751 PDF

    V11518

    Abstract: PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd PT-100 RTD 3 wire sensor - rosemount PT100 rosemount pt100 rtd rosemount rosemount PT-1000 sensor PT-100 RTD 3 wire sensor rosemount Rosemount RTD tH02
    Text: FieldIT Data Sheet 10/11 8.19 EN Temperature Transmitter, head mounted TH02/TH02-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation Level 0: Information • Input – Resistance thermometer (2, 3, 4 wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TH02/TH02-Ex V11518 PT-100 RTD 4 wire sensor - rosemount rosemount pt 100 rtd PT-100 RTD 3 wire sensor - rosemount PT100 rosemount pt100 rtd rosemount rosemount PT-1000 sensor PT-100 RTD 3 wire sensor rosemount Rosemount RTD tH02 PDF

    ceag ghg

    Abstract: ceag ghg atex GHG273 PTB 98 ATEX 3121 BAS 98 ATEX ceag D-69412 interrupteur commutateur ceag ghg 512 D-69412 ceag ghg 270
    Text: Betriebsanleitung Explosionsgeschützte Installationsschalter GHG 273 Operating instructions Explosion protected installation switches GHG 273 Mode d’emploi Interrupteur d’ éclairage pour atmosphères explosives Type: GHG 273 GHG 270 7003 P0001 D/EF/ F


    Original
    P0001 P0001 ceag ghg ceag ghg atex GHG273 PTB 98 ATEX 3121 BAS 98 ATEX ceag D-69412 interrupteur commutateur ceag ghg 512 D-69412 ceag ghg 270 PDF

    th02-ex

    Abstract: transmitter TH02-Ex V11518 tH02 abb SMART temperature Transmitter 3KDE115040R4501 tag 8530 TH02 transmitter PT-1000 sensor prometer
    Text: Data Sheet 10/11-8.19 EN Head mounted Temperature Transmitter TH02/TH02-Ex HART programmable, Pt 100 RTD , thermocouples, electrical isolation • Input – Resistance thermometer (2-, 3-, 4-wire circuit) – Thermocouples – Resistance remote signalling unit (0.5000 Ω)


    Original
    TH02/TH02-Ex th02-ex transmitter TH02-Ex V11518 tH02 abb SMART temperature Transmitter 3KDE115040R4501 tag 8530 TH02 transmitter PT-1000 sensor prometer PDF

    D-69412

    Abstract: PTB 98 ATEX 3121 GHG273 ceag ghg atex CEAG BAS 98 ATEX ceag D-69412 EN50018 ceag ghg M25 BLANKING PLUG
    Text: Betriebsanleitung Explosionsgeschützte Installationsschalter: GHG 273 Operating instructions Explosion protected installation switches: GHG 273 Mode d’emploi Interrupteur d’ éclairage pour atmosphères explosives Type: GHG 273 GHG 270 7003 P0001 D/EF/ H


    Original
    P0001 D-69412 P0001 03/Zi PTB 98 ATEX 3121 GHG273 ceag ghg atex CEAG BAS 98 ATEX ceag D-69412 EN50018 ceag ghg M25 BLANKING PLUG PDF

    GHG 511 4306 R3001

    Abstract: 4407 GHG 514 7407 R0001 GHG 514 4406 R0001 GHG 511 7306 R3001 R3001 GHG 514 4407 R3001 ARRD33 GHG 514 4407 L3001 GHG 514 4406 R3001
    Text: 2: 5: SYS19: BASE2 PDFINFO 50: 95: 98: JOB: CRMAIN06-1070-1 Name: 5P-1070 100: DATE: JAN 19 2006 Time: 6:12:56 PM Operator: RB Hazardous Area Interlocks & Plugs ‘‘GHG’’ Series 5P COLOR: CMYK TCP: 15001 Typedriver Name: TS name Class I, Zone 1 & 2, Div. 2,


    Original
    SYS19: CRMAIN06-1070-1 5P-1070 20/16A 30/32A 60/63A 100/125A CHCC320 CHCC420 CHCC520 GHG 511 4306 R3001 4407 GHG 514 7407 R0001 GHG 514 4406 R0001 GHG 511 7306 R3001 R3001 GHG 514 4407 R3001 ARRD33 GHG 514 4407 L3001 GHG 514 4406 R3001 PDF

    3RT1017

    Abstract: PTB 01 ATEX 3218 3RN1011 SD241B 3RN10 SD241-B ABB contactor ptc temperature sensor motor winding explosion proof abb motor
    Text: Data Sheet 10/68-8.30-EN Motor temperature monitoring unit SD241-B Contrac Pos: 1 /Titelblätter / Copyright/DB/Aktorik/Motortemp. Überwachungseinheit/SD241-B (Contrac) @ 17\mod_1199433838625_3101.doc @ 149407 Motor Temperature Monitoring for Contrac Actuators


    Original
    30-EN SD241-B berwachungseinheit/SD241-B 17\mod 3KXE191001R1001 30-EN 3RT1017 PTB 01 ATEX 3218 3RN1011 SD241B 3RN10 SD241-B ABB contactor ptc temperature sensor motor winding explosion proof abb motor PDF