Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    MCCB TRIPPING CURVES Search Results

    MCCB TRIPPING CURVES Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    ISL88017IHTZ-T Renesas Electronics Corporation 6-Pin Voltage Supervisors with Pin-Selectable Voltage Trip Points Visit Renesas Electronics Corporation
    ISL88017IHTZ-T7A Renesas Electronics Corporation 6-Pin Voltage Supervisors with Pin-Selectable Voltage Trip Points Visit Renesas Electronics Corporation
    ISL88017IHTZ-TK Renesas Electronics Corporation 6-Pin Voltage Supervisors with Pin-Selectable Voltage Trip Points Visit Renesas Electronics Corporation
    ISL88016IHTZ-T Renesas Electronics Corporation 6-Pin Voltage Supervisors with Pin-Selectable Voltage Trip Points, TSOT, /Reel Visit Renesas Electronics Corporation
    ISL88016IHTZ-TK Renesas Electronics Corporation 6-Pin Voltage Supervisors with Pin-Selectable Voltage Trip Points, TSOT, /Reel Visit Renesas Electronics Corporation

    MCCB TRIPPING CURVES Datasheets Context Search

    Catalog Datasheet MFG & Type Document Tags PDF

    Merlin Gerin NS630N

    Abstract: merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb C801N MERLIN GERIN STR22SE merlin gerin multi 9 CT NS400N
    Text: Technical data Section 9 Miniature circuit breakers Breaking capacities Tripping characteristics B type distribution board de-rating table Board Standard MGB4N Split load Multi service Heavy duty Busbar rating 250A 200A 160A 250A 100A Integral MCCB 0.9 0.9


    Original
    MCCB2503D4P) MGB12N) Merlin Gerin NS630N merlin gerin NS250N merlin gerin ns160n C801N NS250N Merlin Gerin mccb C801N MERLIN GERIN STR22SE merlin gerin multi 9 CT NS400N PDF

    MITSUBISHI NF50-HP

    Abstract: NF30-SP NF225-UP NF30-CS NF50-HP Mitsubishi Electric MCCB NF800-SEP NF800-CEP mitsubishi NF630-SEP NF630-CP
    Text: ADVANCED AND EVER ADVANCING MOULDED CASE CIRCUIT BREAKERS TECHNICAL NOTES 98 A We have the pleasure of providing all our customers with the technical information for Mitsubishi moulded case circuit breakers. This indicates the fundamental data of our circuit breakers


    Original
    123Is 1500kVA 6kV/440V 300mm2 J24532 Y-0525-C MITSUBISHI NF50-HP NF30-SP NF225-UP NF30-CS NF50-HP Mitsubishi Electric MCCB NF800-SEP NF800-CEP mitsubishi NF630-SEP NF630-CP PDF

    rac 16a 400v

    Abstract: BW250EAG BW250JAGU
    Text: Molded Case Circuit Breakers List of products G-TWIN Standard Series IEC/EN/GB/JIS conformed Line protection Motor protection AC415V BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 AC415V BW32 BW50 BW63 BW100 BW125 BW250 Icu Icu 1.5kA AAG AAG 2.5kA


    Original
    AC415V BW100 BW125 BW160 BW250 BW400 BW630 BW800 rac 16a 400v BW250EAG BW250JAGU PDF

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE hager 3 phase MCB installation drawing hager mcb HD149U MCCB wiring diagram HD148U IEC 60947-2 max zs HN204 PDF

    DTH circuit diagram

    Abstract: DTH block diagram
    Text: MOULDED CASE CIRCUIT BREAKERS 2 DS Page DTH.E Page DG Page Adjustable Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit Fixed Overload & Fixed Short-circuit release with Normal Breaking Capacity release with High Breaking Capacity Technical Data


    Original
    2/58ROTECTION DTH circuit diagram DTH block diagram PDF

    mccb 60947-2 max zs

    Abstract: 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U
    Text: Auxiliaries and accessories 3.5 RCCB add-on blocks 3.6 Miniature cicruit breakers 80-125A 3.8 Single pole & switch neutral devices 3.15 2 & 4 pole RCCBs 3.16 RCCB auxiliaries 3.17 RCBO single pole 3.18 RCBO single pole and switched neutral 3.19 HRC fuse carriers and


    Original
    0-125A 630ples mccb 60947-2 max zs 60947-2 MAX EARTH LOOP IMPEDANCE wiring diagram of rccb hager mcb 3 phase MCB installation drawing hager HD149U rcbo circuit diagram HMF280T ADA925U PDF

    Untitled

    Abstract: No abstract text available
    Text: Altech UL489 TD / TS Series Molded Case Circuit Breakers UL489 Listed Molded Case Circuit Breaker • • • • • • • • • 4 Frame Sizes LISTED Compact Design E231289 Thermal Magnetic 240, 480, 600VAC 3 Poles Up to 100kA Short Circuit Interrupting Capacity


    Original
    UL489 UL489 E231289 600VAC 100kA TD125 5-125A TS250 50-250A TS400 PDF

    rc 3866

    Abstract: abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE
    Text: MINIATURE CIRCUIT BREAKERS MCBs UL Recognized Supplementar y Pr otectors vs. UL Listed Manual Motor Contr ollers D4A D 16A I 277V AC 277V AC 10000 1D4.0 1DU16 I 10kA LISTED 4C87 UL Recognized UL Listed UL Recognized one pole supplementary protector UL Listed one pole manual motor controller


    Original
    1DU16 3P18U3H/6 3P18U3H/9 3P18U3H/12 3P18U3H/18 3P25U3H/6 3P25U3H/9 3P25U3H/12 3P25U3H/18 3P18U3H/24 rc 3866 abl sursum mcb type b 160A mccb curve 2CU8 2DNU6 3C63 zytel fr 72 3E63 ABL SURSUM 24V 0.5A ROYAL FUSE PDF

    2DU10

    Abstract: mccb 3DU50 3DU32 2DU5 50a mccb 2DU50 1DU05 2DU13 1DU13
    Text: D-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1D 2DN Application Examples: High inrush motors, transformers, power supplies, heaters and reactive loads. Relatively long thermal trip delay and very high magnetic trip point. Prototype testing is recommended in


    Original
    4x10-3 100ms 2DU10 mccb 3DU50 3DU32 2DU5 50a mccb 2DU50 1DU05 2DU13 1DU13 PDF

    Untitled

    Abstract: No abstract text available
    Text: Circuit Breakers for Branch Circuit Protection UL 489 AC & DC Circuit Breakers Miniature MCCB, Circuit Breakers UL Series E301611 Pending • DIN Rail Mounted • Disconnect and Switching Function • 17.5 mm 0.69" Width per Pole • Thermal Magnetic and


    Original
    E301611 480Y/277 50/60Hz AU-1C05UL PDF

    mccb

    Abstract: 2EU30 mccb 3 pole 60A royal fuse time curves 1EU03 1EU05 1EU075 1EU10 1EU12 1EU125
    Text: E-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1E 2EN Application Examples: High efficiency motors, which have exceedingly high inrush currents. Relatively short thermal trip delays and very high magnetic trip points. Prototype testing is recommended.


    Original
    4x10-3 60/63A 100ms mccb 2EU30 mccb 3 pole 60A royal fuse time curves 1EU03 1EU05 1EU075 1EU10 1EU12 1EU125 PDF

    63A MCCB

    Abstract: 1GU20 3GU20 1GU63 2GNU32 1GU03 1GU05 1GU08 3GU40 1GU125
    Text: G-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1G 2GN Application Examples: General industrial, including motors, some transformers, solenoids, control circuits, lighting and wiring. Meets the US trip norms with relatively short thermal trip delay and high magnetic


    Original
    UL508 100ms 2-60A 4x10-3 63A MCCB 1GU20 3GU20 1GU63 2GNU32 1GU03 1GU05 1GU08 3GU40 1GU125 PDF

    1ZU05

    Abstract: mccb 1ZU10 1ZU03 1ZU075 1ZU125 1ZU13
    Text: Z-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1Z 2ZN Application Examples: Semiconductors, components which fail-short vs. fail-open , and components/devices with low surgecurrent and short circuit withstand capabilities. Relatively short thermal


    Original
    UL508 100ms 4x10-2 4x10-3 1ZU05 mccb 1ZU10 1ZU03 1ZU075 1ZU125 1ZU13 PDF

    1CU05

    Abstract: 2CU8 MCCB 50A 3CU63 3CU20 3CU13 MCCB 1CU20 2CU63 3CU60
    Text: C-TRIP CHARACTERISTICS ONE POLE ONE POLE PLUS NEUTRAL 1C 2CN Application Examples: Low inrush motors, lighting, wiring protection, appliances, business equipment, and control circuit applications. Relatively long thermal trip delay and medium magnetic trip


    Original
    1CU03 1CU05 1CU075 1CU10 1CU13 1CU15 1CU16 1CU20 1CU25 1CU30 2CU8 MCCB 50A 3CU63 3CU20 3CU13 MCCB 2CU63 3CU60 PDF

    mccb 60947-2 max zs

    Abstract: memshield 2 MFL1003 bs88 zs levels project on dol starter wiring 18000 rpm DC motor wiring diagram dol motor starter 60947-2 MAX EARTH LOOP IMPEDANCE Eaton MCB Eaton 60947-2 mccb
    Text: 31258 MEM The Guide 1/7/03 16:02 Page 1 MEM Circuit Protection & Control The Guide to Circuit Protection & Control 2003 Issue Technical Support for Electrical Installations 31258 MEM The Guide T H E 1/7/03 16:02 S O U R C E Page 2 O F C I R C U I T P R O T E C T I O N


    Original
    PDF

    140L-R5K3-D80

    Abstract: 140L-N6J3-D25 140L-M5J4-D16 140L-M5J4-D25 140L-M5J3-D25 140L-J6J3-C63 140L-J5J4-D12 140L-J4-EA1R1 IEC-947-2 140L-J5J4-D10
    Text: Bulletin 140L IEC Moulded Case Circuit Breakers Strong Solutions for Line Protection IEC Moulded Case Circuit Breakers 140L Strong Solutions for Line Protection 800 A 630 A 400 A 125 A 250 A Isolation Disconnector Series Economical Series Standard Series High Performance Series


    Original
    140L-SG003A-EN-P 140L-R5K3-D80 140L-N6J3-D25 140L-M5J4-D16 140L-M5J4-D25 140L-M5J3-D25 140L-J6J3-C63 140L-J5J4-D12 140L-J4-EA1R1 IEC-947-2 140L-J5J4-D10 PDF

    WYLEX

    Abstract: carlo gavazzi SP 115 230
    Text: domestic commercial industrial circuit protection Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today across the world.


    Original
    WY2074a WYLEX carlo gavazzi SP 115 230 PDF

    Altech v-ea 52

    Abstract: No abstract text available
    Text: V-EA Series UL508 Listed Manual Motor Controllers “Suitable as Motor Disconnect” • • • • • • DIN Rail Mounted 17.5mm width per pole Thermal Magnetic Current Limiting 0.3-60A / 480Y/277V AC, 50/60Hz 10kA Short Circuit Withstand Capacity • Applications Include:


    Original
    UL508 480Y/277V 50/60Hz E137938 LR104391 E983419 N63UM, Altech v-ea 52 PDF

    GFP13CT34P

    Abstract: GFP13CT33P SDv 210 LV516332 GFP12CT24P
    Text: Low Voltage EasyPact CVS Moulded-case circuit breakers from 100 to 800 A Catalogue 2011 Do you strain to find a high quality circuit breaker that is simple, flexible, and safe? Have tight project budgets restricted you from choosing the best technology products?


    Original
    GFP14CT43P GFP14CT44P CVS800. GFP13CT34P GFP13CT33P SDv 210 LV516332 GFP12CT24P PDF

    shunt trip mccb

    Abstract: 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 ul508a 160A mccb curve iec 947-4-1 400v
    Text: Power Circuit of a UL508A Panel Typical UL508 Application Altech UL508 Disclaimer: This an application example. Installation should be done by a qualified electrician under the guidance of UL/NEC specifications. Altech's V-EA UL508 Manual Motor Controllers


    Original
    UL508A UL508 UL508 E137938 LR104391 480Y/277V 50/60Hz shunt trip mccb 24V 0.5A ROYAL FUSE mccb tripping curve UL508A 28.1 3hp DC motor 220v HP 450 motor 2CU8 160A mccb curve iec 947-4-1 400v PDF

    EATON CA08101001E

    Abstract: No abstract text available
    Text: Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Product Selection WMZT — 10 kAIC at 480/277 Vac. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    877-ETN-CARE PG01101004E Z9940 EATON CA08101001E PDF

    mccb 60947-2 max zs

    Abstract: MCB ENERGY LET THROUGH HRC fuse gg GEC mcb tripping curves mcb technical detail b112c NSB310-C 80A mccb curve 400a mccb Wylex 604
    Text: Circuit Protection 2003 Founded in 1897, Wylex introduced the first ‘consumer unit’ to the electrical industry, this original design was the forerunner to the ‘Standard Range’, which is still in wide use today. From its base at Wythenshawe, through


    Original
    PDF

    shunt trip mccb

    Abstract: e7819 LR43556 JGH3250NN JGE3250NN MTST230V HMCP MTST120V LS CIRCUIT BREAKERS LGE3630NN
    Text: Eaton’s Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A n! Al nglig - Alltid ö pp tillgä e tl id en Alw ! www.chscontrols.se ay op s av ailable - Always Eaton’s Cutler-Hammer Series G Moulded Case Circuit Breakers, 15 - 630 A A New Generation of Moulded Case Circuit Breakers


    Original
    489/CSA SE-254 PM1043E shunt trip mccb e7819 LR43556 JGH3250NN JGE3250NN MTST230V HMCP MTST120V LS CIRCUIT BREAKERS LGE3630NN PDF

    PR221DS

    Abstract: 1SCA0226 Thyristor T6N 1SDA051125R1 ABB inverter motor fault code 1SCA10 T-max T3n 250 ABB inverter motor fault abb motor encoder mounting 1sda01
    Text: With effect from 2nd January 2014 Low Voltage Products Price list ABB low voltage products ABB is a global leader in power and automation technologies that enable utility and industry customers to improve performance while lowering environmental impact. ABB


    Original
    CP/2014 CP/2012 PR221DS 1SCA0226 Thyristor T6N 1SDA051125R1 ABB inverter motor fault code 1SCA10 T-max T3n 250 ABB inverter motor fault abb motor encoder mounting 1sda01 PDF