Untitled
Abstract: No abstract text available
Text: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-K7 This Hall Effect current sensor is based on open loop compensating principle and can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave of the current carrying conductor.
|
Original
|
PDF
|
D-85464
CYHCS-K7-05A
CYHCS-K7-10A
CYHCS-K7-15A
CYHCS-K7-20A
CYHCS-K7-25A
CYHCS-K7-30A
CYHCS-K7-40A
CYHCS-K7-50A
|
Untitled
Abstract: No abstract text available
Text: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-K200 This Hall Effect current sensor is based on open loop principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the
|
Original
|
PDF
|
CYHCS-K200
CYHCS-K200
D-85464
|
Untitled
Abstract: No abstract text available
Text: Technologies GmbH & Co KG Open Loop Hall Current Sensor CYHCS-B200 This Hall Effect current sensor is based on closed loop principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the real wave
|
Original
|
PDF
|
CYHCS-B200
CYHCS-B200
D-85464
|
Untitled
Abstract: No abstract text available
Text: Technologies GmbH & Co KG Closed Loop Hall Current Sensor CYHCS-SYA This Hall Effect current sensor is based on the closed loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the
|
Original
|
PDF
|
D-85464
|
Untitled
Abstract: No abstract text available
Text: Technologies GmbH & Co KG Closed Loop Hall Current Sensor CYHCS-B8 This Hall Effect current sensor is based on the closed loop compensating principle and designed with a high galvanic isolation between primary and secondary circuits. It can be used for measurement of DC and AC current, pulse currents etc. The output of the transducer reflects the
|
Original
|
PDF
|
D-85464
|
hall current transducer 5A
Abstract: HY-10 transistor marking hy hy power HY-5 M 9639 20-P 25-P hall ac current transducer 10A ho 10-p
Text: HY 5.25-P Definition The HY.-P is a compact and low-cost transducer for the measurement of small current. It works on the Hall effect principle and allows measurement with galvanic isolation of DC, AC or other currents of complex wave form. Operating from a +/-15V power supply and over a wide temperature range, it is suitable for use in current
|
Original
|
PDF
|
/-15V
/-40mV
hall current transducer 5A
HY-10
transistor marking hy
hy power
HY-5
M 9639
20-P
25-P
hall ac current transducer 10A
ho 10-p
|
hall current transducer 10A
Abstract: hall ac current transducer 10A HCT-100 transducer diagram
Text: CUSTOMER INTERNAL CODE HCT-LP CUSTOMER CODE DATE 23/08/10 PART DESCRIPTION HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP HCT 200A 1:200 C. Output EDITION 1 DOCUMENT NAME HCT-LP_1.doc PAGE 1/8 HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP HCT 200 A 1:2000 (C.Output)
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: CUSTOMER CUSTOMER CODE PART DESCRIPTION HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP HCT 30A 1:1500 V. Output INTERNAL CODE HCT-PX5 DATE 05/11/10 EDITION 2 DOCUMENT NAME HCT-PX5_2.doc PAGE 1/6 HALL EFFECT CURRENT TRANSDUCER CLOSED LOOP 30A 1:1500 (V. Output)
|
Original
|
PDF
|
HCT-30PX5
|
hall current transducer 10A
Abstract: HCT-300LTP hall ac current transducer 10A AWG14 burden resistor
Text: CUSTOMER CUSTOMER CODE PART DESCRIPTION HALL EFFECT CURRENT TRANSDUCER HCT 900A PEAK INTERNAL CODE HCT-300LTP DATE 23/08/10 EDITION 1 DOCUMENT NAME HCT-300LTP_1.doc PAGE 1/4 HALL EFFECT CURRENT TRANSDUCER 900 A PEAK. HCT-300LTP NOTES All rights reserved. Passing on of this document, use and communication of contents not permitted without written authorisati on.
|
Original
|
PDF
|
HCT-300LTP
HCT-300LTP
hall current transducer 10A
hall ac current transducer 10A
AWG14
burden resistor
|
28644
Abstract: HA200-SB 500-SBD 25-NP 400-SID 200-SU PRIM configuration hall current transducer 10A hall current transducer LA 100P construction hall effect transducers
Text: Issued March 1995 019-307 Data Pack E Data Sheet Hall effect transducers, current and voltage This data sheet covers the following products: RS stock no. 286-311 286-327 286-333 286-349 286-355 286-377 286-383 286-399 286-406 286-412 286-428 286-434 286-440
|
Original
|
PDF
|
50/100A
28644
HA200-SB
500-SBD
25-NP
400-SID
200-SU
PRIM configuration
hall current transducer 10A
hall current transducer LA 100P
construction hall effect transducers
|
LV 25-P
Abstract: LV 25-NP HA200-SB hall current transducer LA 100P 286377 50psp1 200-SRI 500-SBD HT 200-srud PCB Mounting Hall Effect Current Transformer
Text: Issued March 2001 232-5250 Data Pack E Data Sheet Hall effect transducers, current and voltage This data sheet covers the following products: RS stock no. 286-311 286-327 286-333 286-349 286-355 286-377 286-383 286-399 286-406 286-412 286-434 286-456 286-462
|
Original
|
PDF
|
50/100A
LV 25-P
LV 25-NP
HA200-SB
hall current transducer LA 100P
286377
50psp1
200-SRI
500-SBD
HT 200-srud
PCB Mounting Hall Effect Current Transformer
|
HT 200-srud
Abstract: 100ARMS HA200-SB schematic diagram induction heating hall current transducer 10A hall current transducer LA 100P voltage measurement LV 25-P PCB Mounting Hall Effect Current Transformer 200-SU 400-SID
Text: Issued March 1997 232-5250 Data Pack E Data Sheet Hall effect transducers, current and voltage This data sheet covers the following products: RS stock no. 286-311 286-327 286-333 286-349 286-355 286-377 286-383 286-399 286-406 286-412 286-428 286-434 286-440
|
Original
|
PDF
|
50/100A
HT 200-srud
100ARMS
HA200-SB
schematic diagram induction heating
hall current transducer 10A
hall current transducer LA 100P
voltage measurement LV 25-P
PCB Mounting Hall Effect Current Transformer
200-SU
400-SID
|
HA200-SB
Abstract: construction hall effect transducers 200-SI 500w power amplifier pcb diagram 100ARMS PCB Mounting Hall Effect Current Transformer HT 200-srud 25-NP HT 500 srud transducers
Text: E17755 Issued July 1994 Halleffect transducers,current and voltage This data sheet covers the following products. RS stock no. 286-311 286-327 286-333 286-349 286-355 286-377 286-383 286-399 286-406 286-412 286-428 286-434 286-440 286-456 286-462 286-478 286-484
|
Original
|
PDF
|
E17755
50/100A
HA200-SB
construction hall effect transducers
200-SI
500w power amplifier pcb diagram
100ARMS
PCB Mounting Hall Effect Current Transformer
HT 200-srud
25-NP
HT 500 srud
transducers
|
Fluke 179 Multimeter circuit diagram
Abstract: flux multimeter
Text: ACS704ELC-005 Fully Integrated, Hall Effect-Based Linear Current Sensor with Voltage Isolation and a Low-Resistance Current Conductor The Allegro ACS704 family of current sensors provides economical and precise solutions for current sensing in industrial, automotive, commercial, and
|
Original
|
PDF
|
ACS704ELC-005
ACS704
ACS704ELC005-DS,
Fluke 179 Multimeter circuit diagram
flux multimeter
|
|
Untitled
Abstract: No abstract text available
Text: AUTOMOTIVE CURRENT TRANSDUCER DHAB S/44 Introduction Principle of DHAB Family The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation between the primary
|
Original
|
PDF
|
30m/s2,
|
Untitled
Abstract: No abstract text available
Text: AUTOMOTIVE CURRENT TRANSDUCER DHAB S/06 Introduction Principle of DHAB Family The DHAB family is best suited for DC, AC, or pulsed currents measurement in high power and low voltage automotive applications. Its contains galvanic isolation between the primary
|
Original
|
PDF
|
30m/s2,
|
741 LEM
Abstract: No abstract text available
Text: Voltage Transducer LV 100 For the electronic measurement of voltage: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. Electrical data Features Primary nominal current rms Primary current, measuring range Measuring resistance
|
Original
|
PDF
|
28July2011/version
741 LEM
|
tc25a4v
Abstract: hall current transducer 5A hall ac current transducer 10A tc50a4v
Text: Topstek Current Transducer TC5A . TC50A TC 5A~50A Features iHighly reliable Hall Effect device iCompact and light weight iFast response time iExcellent linearity of the output voltage over a wide input range iExcellent frequency response > 50 kHz iLow power consumption (9 mA nominal)
|
Original
|
PDF
|
TC50A
TC50A
V080201
TC50A-P
TC50A-P
tc25a4v
hall current transducer 5A
hall ac current transducer 10A
tc50a4v
|
TB10A4V
Abstract: hall current transducer 5A TB15A TB-37 TB15A4V Topstek code marking 5A
Text: Topstek Current Transducer TB5A . TB37.5A TB 5A~37.5A Features iHighly reliable Hall Effect device iCompact and light weight iFast response time iExcellent linearity of the output voltage over a wide input range iExcellent frequency response > 50 kHz iLow power consumption (9 mA nominal)
|
Original
|
PDF
|
V080201
TB10A4V
hall current transducer 5A
TB15A
TB-37
TB15A4V
Topstek
code marking 5A
|
hall ac current transducer 10A
Abstract: welding inverter dc to ac
Text: Topstek Current Transducer TGD3A . TGD40A TGD 3A~50A Applications Features iHighly reliable Hall Effect device iCompact and light weight, Two sensors in one package iFast response time iExcellent linearity of the output voltage over a wide input range iExcellent frequency response > 50 kHz
|
Original
|
PDF
|
TGD40A
V080708
0A-14A
5A-24A
5A-40A
V0800708
hall ac current transducer 10A
welding inverter dc to ac
|
Open Loop Current Transducer
Abstract: ta18.5a4v TA25A4V hall current transducer 5A hall current transducer 10A TA15A TA50A4V TA10A4V hall ac current transducer 10A Open Loop Current Transducer 20A
Text: Topstek Current Transducer TA5A4V . TA50A4V Open Loop Current Transducers TA 5A~50A Features Applications iHighly reliable Hall Effect device iCompact and light weight iFast response time iExcellent linearity of the output voltage over a wide input range
|
Original
|
PDF
|
TA50A4V
TA50A
V080201
TA50A-P
TA50A-P
Open Loop Current Transducer
ta18.5a4v
TA25A4V
hall current transducer 5A
hall current transducer 10A
TA15A
TA50A4V
TA10A4V
hall ac current transducer 10A
Open Loop Current Transducer 20A
|
hall current transducer 3A
Abstract: hall current transducer 5A
Text: Topstek Current Transducer THDD5A . THDD50A THDD 5A~50A Features Applications iHighly reliable Hall Effect device iCompact and light weight. Two sensors in one package iFast response time iExcellent linearity of the output voltage over a wide input range
|
Original
|
PDF
|
THDD50A
V080201
hall current transducer 3A
hall current transducer 5A
|
Untitled
Abstract: No abstract text available
Text: Current Transducer LF 2005-S/SP9 For the electronic measurement of currents: DC, AC, pulsed., with galvanic isolation between the primary circuit and the secondary circuit. IPN = 1000 A 16178 Electrical data Features Primary nominal current rms 1000 Primary current, measuring range @ ± 24 V
|
Original
|
PDF
|
2005-S/SP9
29September2011/version
|
103SR5A-2
Abstract: TDK ultrasonic transducer 103SR5A-1 47XL31XC-03 413SR15 ultrasonic receiver 400SR 400Sr ultrasonic transducer 47XL31XC-02 micro switch V3 TESLA NU 73
Text: MICRO SWITCH Specifier's Guide for Solid State Sensors Hall Effect Position Sensors Magnetoresistive Position Sensors Current Sensors Catalog 20 Issue 11 • December 1991 MICRO SWITCH a Honeywell Division For unsurpassed reliability MICRO SWITCH Solid State Sensors
|
OCR Scan
|
PDF
|
103SR
103SR5A-1.
103SR11A-1
103SR12A-1
103SR13A-1
103SR15A-10.
103SR17A-1
103SR18-1.
103SR5A-2
TDK ultrasonic transducer
103SR5A-1
47XL31XC-03
413SR15
ultrasonic receiver 400SR
400Sr ultrasonic transducer
47XL31XC-02
micro switch V3
TESLA NU 73
|