FRN-R-50ID
Abstract: No abstract text available
Text: Fusetron FRN-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 250 Volt Catalog Symbol: FRN-R_ID Current-Limiting Dual-element, time-delay – 10 seconds minimum at 500% rated current (8 seconds for 0-30A sizes) Ratings: Volts – 250Vac (or less)
|
Original
|
PDF
|
250Vac
200kA
125Vdc
E4273
BU-SB09408
FRN-R-50ID
|
Untitled
Abstract: No abstract text available
Text: Fusetron FRN-R_ID Dual-Element, Time-Delay Fuses with Indication Class RK5 - 250 Volt Now Available With Optional Indication Catalog Symbol: FRN-R_ID Current-Limiting Dual-element, time-delay – 10 seconds minimum at 500% rated current (8 seconds for 0-30A sizes)
|
Original
|
PDF
|
250Vac
200kA
125Vdc
E4273
FRN-R-10ID
FRN-R-12ID
FRN-R-15ID
FRN-R-17
FRN-R-20ID
FRN-R-25ID
|
fusetron
Abstract: No abstract text available
Text: Bussmann Fusetron® FRN-R Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt 70-600A Dimensional Data 5.88" ± 0.062 1.06" (± 0.008) 70A to 100A 7.13" (± 0.062) 1.56" (± 0.008) 110A to 200A 8.63" (± 0.094) 2.06" (± 0.008) 225A to 400A 10.38" (± 0.094)
|
Original
|
PDF
|
0-600A
250Vac
125Vdc
0-200A)
250Vdc
01-600A)
E4273
FRN-R-70
FRN-R-75
FRN-R-80
fusetron
|
FRN-R300
Abstract: FRNR350 FRNR-600 FRNR70 FRNR250 FRNR-450 fusetron 2664-R frnr.200 FRNR-80
Text: Bussmann Fusetron® FRN-R Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt 70-600A Dimensional Data 5.88" ± 0.062 1.06" (± 0.008) 70A to 100A 7.13" (± 0.062) 1.56" (± 0.008) 110A to 200A 8.63" (± 0.094) 2.06" (± 0.008) 225A to 400A 10.38" (± 0.094)
|
Original
|
PDF
|
0-600A
E4273
A00115
FRN-R300
FRNR350
FRNR-600
FRNR70
FRNR250
FRNR-450
fusetron
2664-R
frnr.200
FRNR-80
|
Untitled
Abstract: No abstract text available
Text: FUSETRON 250V Class RK5 FRN-R — 250Vac/125Vdc, 1⁄10-60A, Dual Element, Time-Delay Fuses Dimensions - in 2" ± 0.31 3" (± 0.31) 0.56" (±0.008) 0.81" (±0.008) 1/10 to 30A Description: Advanced protection, energy efficient Class RK5 dual element, current-limiting, time-delay fuses with optional
|
Original
|
PDF
|
250Vac/125Vdc,
0-60A,
0-30A
250Vac,
125Vdc
200kA
BU-SB13730
|
Untitled
Abstract: No abstract text available
Text: Low Voltage, Branch Circuit Rated Fuses Fusetron dual-element, time-delay fuses FRN-R 250V Class RK5 Current Limitation Curves AMPERE RATING FRN-R (250V) 100,000 600 400 200 100 60 10,000 30 200,000 10,000 1,000 100,000 A 1,000 Features and Benefits • Separate overload and short-circuit elements provide time
|
Original
|
PDF
|
10A-600A
|
3PRA 20
Abstract: BUSSMANN KTK-15 JJS-45 KTU-80 3PRA 60 FRS-R-40 20SP 012 LPJ-20SP FRN-R-10 LPJ-400SP
Text: Niederspannungs-Sicherungseinsätze für industrielle Anwendungen Allgemeine Angaben - Maße Zoll Klasse J Klasse T Klasse RK5 und RK1 ® Low-Peak und Limitron Sicherungen LPJ und JKS (600V) T-Tron Sicherungen JJN (300V) JJS (600V) Fusetron®-, Low-Peak®- und
|
Original
|
PDF
|
FNQ-15
FNQ-20
FNQ-25
FNQ-30
3PRA 20
BUSSMANN KTK-15
JJS-45
KTU-80
3PRA 60
FRS-R-40
20SP 012
LPJ-20SP
FRN-R-10
LPJ-400SP
|
fusetron
Abstract: fusetron dual element Time-Delay fuse RK5 fuse MEXICO FUSE Ferraz Shawmut ot master replacement guide Ferraz Shawmut fusetron frn dual element Time-Delay fuse FLNR crn fuse
Text: Finding The Open Fuse Is Now as Easy as easy ID With the New Cooper Bussmann Fusetron® easy ID™ Class RK5 Cartridge Fuses Now, a drop-in replacement is available to consumers that want to find their open fuses faster. The Cooper Bussmann line of FRN-R 250 volt
|
Original
|
PDF
|
|
FRN-R-30
Abstract: DSA006401 FRN-R-15 FRN-R-3.2 FRN-R-61/4 FRN-R-25 FRNR-3.2 FRN-R6 FRN-R-20 FRN-R-45
Text: Fusetron FRN-R Dual-Element, Time-Delay Fuses Class RK5 - 250 Volt ⁄10-60A 1 Dimensional Data 2" ± 0.31 0.56" (± 0.008) 1/10 A to 30A 3" (± 0.31) 0.81" (± 0.008) 35A to 60A Catalog Symbol: FRN-R Current-Limiting Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
|
Original
|
PDF
|
/10-60A
250Vac
125Vdc
E4273
FRN-R-1/10
FRN-R-18/10
FRN-R-15/100
FRN-R-21/4
BU-SB08353
FRN-R-30
DSA006401
FRN-R-15
FRN-R-3.2
FRN-R-61/4
FRN-R-25
FRNR-3.2
FRN-R6
FRN-R-20
FRN-R-45
|
fusetron
Abstract: FRN-R-25 FRN-R-10 FRN-R-12 FRN-R-15 FRN-R-30 FRN-R-35 FRN-R-40 FRN-R-50 FRN-R6
Text: Bussmann Fusetron® FRN-R Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt ⁄Ω¡º-60A Dimensional Data 2" ± 0.31 .56" (± 0.008) 1/10 A to 30A 3" (± 0.31) .81" (± 0.008) 35A to 60A Catalog Symbol: FRN-R Current-Limiting Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
|
Original
|
PDF
|
E4273
SB99013
fusetron
FRN-R-25
FRN-R-10
FRN-R-12
FRN-R-15
FRN-R-30
FRN-R-35
FRN-R-40
FRN-R-50
FRN-R6
|
RK5 fuse
Abstract: FRN-R300 FRN-R-225 frn-r-70 fusetron frn FRN-R-100 FRN-R-110 FRN-R-80 FRN-R-90 250 volt to 600 volt fuse
Text: Fusetron FRN-R Dual-Element, Time-Delay Fuses Class RK5 – 250 Volt 70-600A Dimensions - in 5.88” 1.06” 70 to 100A 7.13” 1.56” 110 to 200A 8.63” ± 0.094 2.38” ± 0.020 225 to 400A 10.38” ± 0.094 2.88” ± 0.020 Catalog Symbol: FRN-R †
|
Original
|
PDF
|
0-600A
250Vac
125Vdc
10-200A)
250Vdc
25-600A)
E4273
FRN-R-70
FRN-R-125
FRN-R-350
RK5 fuse
FRN-R300
FRN-R-225
frn-r-70
fusetron frn
FRN-R-100
FRN-R-110
FRN-R-80
FRN-R-90
250 volt to 600 volt fuse
|
Untitled
Abstract: No abstract text available
Text: FUSETRON 250V Class RK5 FRN-R — 250Vac/125Vdc, 70-600A, Dual Element, Time-Delay Fuses Dimensions - in 8.63” ± 0.094 5.88” 1.06” 2.38” ± 0.020 225 to 400A 70 to 100A 10.38” ± 0.094 7.13” 1.56” 450 to 600A 110 to 200A Description: Advanced protection, energy efficient Class RK5
|
Original
|
PDF
|
250Vac/125Vdc,
0-600A,
250Vac
125Vdc
10-200A)
250Vdc
25-600A)
0-600A
200kA
E4273
|
Class J Fuses
Abstract: fusetron t E4273 3.15A 250V fuse FUSE T 3.15A 250V special purpose Fuses cooper lpj_sp 800 bussmann fuse fnq-r
Text: Fuseology Cooper Bussmann Branch Circuit, Power Distribution Fuses Low-Peak Fuses* Now Offer Indication That's As Clear As Black And White Good Low-Peak current-limiting fuses offer optional permanent replacement fuse indication. The indicator is either
|
Original
|
PDF
|
600Vac)
250Vac)
125Vdc,
000AIR)
5-600A
250Vdc,
300Vdc,
E56412,
Class J Fuses
fusetron t
E4273
3.15A 250V fuse
FUSE T 3.15A 250V
special purpose Fuses cooper
lpj_sp 800
bussmann fuse fnq-r
|
Buss MTH7
Abstract: Buss GLH
Text: Pg 198 to 205 / 12-15-01 1/3/02 5:26 PM Page 198 Bussmann Fuse Accessories, Displays, Kits, Etc. Accessories Spare Fuseholders • Durable construction using black thermoplastic with UL94-VO flammability rating. • Common mounting using #6 screws or bolts on 5-inch centers.
|
Original
|
PDF
|
UL94-VO
FNQ-20
FRN-R-25
FNQ-25
FRN-R-30
FRS-R-10
FNQ-30
FRN-R-35
FRS-R-15
FRN-R-40
Buss MTH7
Buss GLH
|
|
kcc cl-150
Abstract: 3PRA 20 3PRA 60 5a 20SP 012 KRPC-3000 buss fusetron fusetron dual element FUSE FNM-6 IR 200 A mcm 750 100a 15sp 012 J60400-1CR
Text: General Data — Selection Chart Bussmann Buss Fuse Selection Chart 600 Volts or Less Circuit Load Ampere Fuse Rating Type Symbol Voltage Rating (a-c) Class Interrupting Rating (KA) Remarks All-purpose fuses. Unequaled for combined short-circuit and overload protection.
|
Original
|
PDF
|
01-6000A)
kcc cl-150
3PRA 20
3PRA 60 5a
20SP 012
KRPC-3000
buss fusetron
fusetron dual element FUSE FNM-6 IR 200 A
mcm 750 100a
15sp 012
J60400-1CR
|
15sp
Abstract: fnqr10 KTK Fuses fusetron fuse 3A M/NTC 15sp fnq 10 fuse LPS-RK-10-SP GSK-260 LPCC-30 LPCC-15
Text: Service Kits Reduce Downtime With Quick Access To The Right Replacement Fuse Select From Six New Cooper Bussmann Service Kits • Selection These new fuse service kits are filled with the most common fuse types and sizes for the most common applications: choose from Class J, RK1, RK5, CC,
|
Original
|
PDF
|
LPN-RK-25SP
LPN-RK-30SP
LPN-RK-60SP
LPN-RK-100SP
LPS-RK-10SP
LPS-RK-15SP
LPS-RK-20SP
LPS-RK-30SP
JSK-36
LPJ-10SP
15sp
fnqr10
KTK Fuses
fusetron fuse 3A
M/NTC 15sp
fnq 10 fuse
LPS-RK-10-SP
GSK-260
LPCC-30
LPCC-15
|
Untitled
Abstract: No abstract text available
Text: Low Voltage, Branch Circuit Rated Fuses Branch circuit rated fuse dimensions Low Voltage Branch Circuit Fuses Class J Dimensions - in mm Low-Peak and Limitron® Fuses LPJ & JKS — 600V Amp Range 1-30 A B 2.25 (57.2) 0.81 (20.6) C D — E — 0.50 (12.7)
|
Original
|
PDF
|
|
T32 fuse l 250v
Abstract: LPCC-20 LPJ600SP NOS 600 amp fuses LPSRK1712SP LPJ-20SP CDF30J3 EFJ30X-3PB6 fuse base IEC 269 KRPC2000SP
Text: Low Voltage, Branch Circuit Rated Fuses Page 12-14 15-16 Class Fuses Volts CC . . . . . . LP-CC . . . . . . . . . . . . . . . 600V . . . . . 17 FNQ-R . . . . . . . . . . . . . . . KTK-R . . . . . . . . . . . . . . . 600V . . . . . 600V . . . . . 18 19 600V . . . . .
|
Original
|
PDF
|
SA-3-2/10*
SA-10*
SA-15*
SA-20*
SA-30*
SA-1-6/10
SA-3-2/10
SA-10
SA-15
SA-20
T32 fuse l 250v
LPCC-20
LPJ600SP
NOS 600 amp fuses
LPSRK1712SP
LPJ-20SP
CDF30J3
EFJ30X-3PB6
fuse base IEC 269
KRPC2000SP
|
fusetron class k9
Abstract: No abstract text available
Text: Pg206 to 230 /12-25-01 1/3/02 3:42 PM Page 206 Fuse Technology Circuit Protection Electrical distribution systems are often quite complicated. They cannot be absolutely fail-safe. Circuits are subject to destructive overcurrents. Harsh environments, general deterioration, accidental damage, damage from natural causes, excessive expansion, and/or overloading of the electrical distribution system are
|
Original
|
PDF
|
Pg206
fusetron class k9
|
bussmann Fuse 170L series
Abstract: HTC Korea evf 8202 FM09A Cooper Bussmann kbt 300 buss fusetron mdl mdx Fuses BC603 MDM 4 COOPER BUSSMANN buss F03B
Text: Cooper Bussmann Services & Application Guide Downtime Reduction, Workplace Safety & Code Compliance Services to Increase Your Productivity Through Protection Section Contents Cooper Bussmann Services Engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .370
|
Original
|
PDF
|
DK-2740
bussmann Fuse 170L series
HTC Korea
evf 8202
FM09A
Cooper Bussmann kbt 300
buss fusetron mdl
mdx Fuses
BC603
MDM 4 COOPER BUSSMANN
buss F03B
|
Untitled
Abstract: No abstract text available
Text: High Speed Fuses Square body DIN 43 653 — 690V/700V IEC/UL : 40-2000A 690V/700V (IEC/UL) 40-2000A Arc Voltage Specifications Description: Square body DIN 43 653 stud-mount high speed fuses. Dimensions: See dimensions illustration. Ratings: Volts: — 690Vac (IEC)
|
Original
|
PDF
|
90V/700V
0-2000A
690Vac
700Vac
200kA
FRN-R-200
2x103
|
220v AC voltage stabilizer schematic diagram
Abstract: 11kV breaker control circuit diagram 110 KW motor 11kv 170H1007 price list for bussmann semiconductor fuse 10SP 010 fusetron dual element fnm-5 3PRA 20 HRC fuse gg GEC 10SP 005
Text: Bussmann Circuit Protection Solutions Bussmann ® Worldwide Circuit Protection Solutions World’s leading supplier of fuses and fusible protection systems, Bussmann continues its 88-year history of blazing new trails of innovative technologies. Maker of the industry’s first
|
Original
|
PDF
|
88-year
10-02-50M
30-Amp
60-Amp
IP-20)
30Amp
60-Amp
10-02-40M
220v AC voltage stabilizer schematic diagram
11kV breaker control circuit diagram
110 KW motor 11kv
170H1007
price list for bussmann semiconductor fuse
10SP 010
fusetron dual element fnm-5
3PRA 20
HRC fuse gg GEC
10SP 005
|
Transformer Protection
Abstract: 400kVA C3746 400kva transformer 800va ups circuit bussmann Fuse 170M series 4503 transformer JCW-1E fuse 170m 800va ups
Text: Equipment Protection Transformers — 600V or Less The requirements of 450.3 cover only transformer protection. In practice, other components must be considered in applying circuit overcurrent protection. For circuits with transformers, requirements for conductor protection per Articles
|
Original
|
PDF
|
5500V
7500V
4000V
6000V
8000V
Transformer Protection
400kVA
C3746
400kva transformer
800va ups circuit
bussmann Fuse 170M series
4503 transformer
JCW-1E
fuse 170m
800va ups
|
STK and STR integrated circuits
Abstract: 12v 100 amp battery load tester CBC-40HB CB185P-60 VP/ATM-15-RP
Text: Consumer aftermarket product catalog Automotive and Hardware/Home Center circuit protection products and accessories A total retail program from the brand consumers have trusted for nearly 100 years. Bussmann is now a part of Eaton. Same great products plus even more.
|
Original
|
PDF
|
|