polishing compound
Abstract: 58424-1 501523
Text: Instruction Sheet 408-4151 ST Stainless Steel Ferrule Connector Kits and Coupling Receptacle 03 DEC 08 Rev B Connector Kit Metal Bend-Limiting Coupling Strain Relief Nut Alignment Trim Line Key Crimp Eyelet With Rolled End Long Strain Relief Protective Connector
|
Original
|
PDF
|
|
anaerobic activator loctite 7649
Abstract: Loctite 7649 activator LOCTITE 648
Text: ST Ceramic and Polymer Ferrule Connector Kits and Coupling Receptacle Instruction Sheet 408-9971 08 DEC 08 Rev H Small Diameter Tubing m Used with 250- m Coated Fiber Short Boot Connector Kit Bare Buffer Boot m PVC Tubing (Used with 900- m Buffered Fiber)
|
Original
|
PDF
|
|
EPO TEK 353ND
Abstract: FERRULE MSDS luxcis 1918509 353nd cure 1828644-2 Radiall assembly instructions 502282-2 miller fiber stripper
Text: Instruction Sheet LuxCis Fiber Optic Connector Terminus Kits 1828199- 1 and 1828200- 1 ML MM Terminus Kit 1828199- 1 For Loose and Tight Cable Structure 408- 10275 16 NOV 09 MT MM Terminus Kit 1828200- 1 (For Ultra Tight Cable Structure) Crimp Sleeve Crimp
|
Original
|
PDF
|
|
Tyco automotive connectors
Abstract: FERRULE MSDS D956 tyco connector automotive heat shrink tubing spring loaded connector spring loaded terminal connector pin contact RG58-LL HAND CLEANER MSDS
Text: Application Specification Automotive Mini UHF Plastic Snap-Lock Coaxial Connectors NOTE i 114-13044 27 JUN 07 Rev B All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
needle mixer
Abstract: STRIP TEMPLATE SC TIP 120c 353nd polish ferrule SC EPO-TEK 353ND cladding mode strip
Text: Instruction Sheet Tight- Jacketed Fiber SC Connector Kits 1828573- [ ],1828574- [ ], 6828099- [ ], and 6828100- [ ] 408- 10015 19 MAR 10 Rev E Simplex Connector Kit Bend- Limiting Boot Crimp Eyelet/Heat Shrink Assembly Duplex Connector Kit Bend- Limiting
|
Original
|
PDF
|
|
Loctite 7649 activator
Abstract: FERRULE MSDS 1588756-1 353nd Receptacle LC 1588175-1G STRIP TEMPLATE lC
Text: Instruction Sheet Simplex Jumper and Duplex 408-10014 Jumper Tight-Jacketed Fiber LC Connector Kits 16 JAN 08 Rev D Simplex Jumper LC Connector Kit Bend Limiting Boot Crimp Eyelet/Heat Shrink Assembly Duplex Jumper LC Connector Kit Bend Limiting Protective
|
Original
|
PDF
|
|
8675
Abstract: STRIP TEMPLATE lC Loctite 7649 MSDS 1588756-1 FERRULE MSDS 501523-1
Text: Instruction Sheet 408- 8675 LC Standard and LC SECURE Product Line Connector Kits 22 DEC 09 Rev K 1.6- to 2.4- mm Duplex Jumper LC Standard Connector Kit Duplex Buffer LC Standard Connector Kit Bend Limiting Boots Buffer Boots Connector Subassemblies Protective
|
Original
|
PDF
|
|
STRIP TEMPLATE SC
Abstract: Loctite 7649 ACTIVATOR 7649 Loctite 7649 MSDS 492025-1 16933 353nd LOCTITE 648 408-8674 LOCTITE 408
Text: SC- and FC-Type Singlemode and Multimode Simplex and Duplex Connector Kits Instruction Sheet 408-8674 29 OCT 08 Rev F Simplex Connector Kit Bend Limiting Boot Buffer Boot Heat Shrink Assembly Housing Protective Cover Connector Subassembly Housing Protective
|
Original
|
PDF
|
|
crimping positioners by manufacturer
Abstract: k920 Daniels AFM8 AFM8 749958 FERRULE MSDS AMP Coaxial Connector Y196 58237-1 4-40 brass jackscrew "installation torque"
Text: Application Specification AMPLIMITE* Connectors for Coaxial and Signal HD- 20 Contacts 114- 40032 11 NOV 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
HD--20
crimping positioners by manufacturer
k920
Daniels AFM8
AFM8
749958
FERRULE MSDS
AMP Coaxial Connector
Y196
58237-1
4-40 brass jackscrew "installation torque"
|
KAH-60
Abstract: No abstract text available
Text: fiber optic connectors AND aSSEMBLIES general catalogue Edition 2006/2007 HUBER+SUHNER Excellence in Connectivity Solutions Further Fiber Optic Catalogues System catalogue LISA Item no. 23040188 Cables Item no. 84019826 Cabling systems Item no. 23040188 Passive network components
|
Original
|
PDF
|
|
25003
Abstract: pneumatic arm CHAMPOMATOR 2.5 BENCH TERMINATING MACHINE flat ribbon cable notcher SN60 SN62 408-6790 408-series
Text: Application Specification 114- 25032 AMPMODU* Mass Termination MT Interconnection System NOTE i 23 OCT 09 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
|
M24792A
Abstract: AB-9112 curing Fiber Optic Technical Training Manual 353nd 182-001P 01-1A-505-4 181-075 EPO-TEK 353ND D38999
Text: Series 80 Mighty Mouse Size #16 Fiber Optic Termini Single Mode and Multi Mode Snap-in, Rear Release Precision Ceramic Ferrules 0.5 dB Typical Attenuation 1 to 22 Channels Series 801 Plug with 181-057 pin terminus Series 801 receptacle with 181-075 socket
|
Original
|
PDF
|
D38999
4-JUNE-2010
M24792A
AB-9112
curing
Fiber Optic Technical Training Manual
353nd
182-001P
01-1A-505-4
181-075
EPO-TEK 353ND
|
raychem EPD-RWC
Abstract: EPD-RWC BMS13-72 BMS13 BPS-C-193 QUADRAX CONNECTOR EPD-RWC-18279 114-13123 K709 QUADRAX CABLE
Text: Application Specification Quadrax Rectangular Connectors and Quadrax Contacts NOTE i 114- 13123 08 FEB 10 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
|
108-10047
Abstract: Miniature circular DIN connector Tyco manual Semi-automatic for crimping SN60 SN62 408-7424 crimp 408-7424 354500-1 circular CONNECTORS 37 pin layout 69710-1 REV G
Text: Application Specification Circular DIN Standard and Shielded Connectors and Contacts NOTE i 114- 40025 11 NOV 09 Rev D All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
|
|
permabond e04
Abstract: WHMA-A-620 loctite 262 Loctite E04 raychem termination manual permabond Loctite 262 data raychem cable termination manual UV15-7TK1A tinel ring
Text: Application Specification 114-13201 Metal-Shell Micro Circular Connectors NOTE 13 NOV 07 All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and Rev A _ inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2 .
|
Original
|
PDF
|
|
raychem termination manual
Abstract: 114-13123 raychem heat shrink boots 1738894-1 quadrax socket quadrax socket CRIMPING QUADRAX CONNECTOR raychem cable termination manual QUADRAX CABLE raychem termination kit 408-2766
Text: Application Specification 114- 13163 Quadrax Circular Connectors and Quadrax Contacts NOTE i 08 FEB 10 Rev C All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
|
Loctite 7500 MSDS
Abstract: Loctite 414 MSDS M83526 M85045 SMA 905 ferrule drawing M23053 6250-0-1P-0 .375-24 UNF-2B tvs diode sma marking code fo d38999 flammability
Text: Fiber Optic Interconnect Solutions Tactical Fiber Optic Connectors, Cables and Termini U n i t e d S t a t e s U n i t e d K i ng d om G e r m a n y F r a nc e N o r d i c I t a ly Spain Japan Six Reasons to Upgrade to Fiber Optics: 1. Reduced Weight
|
Original
|
PDF
|
|
GCB1000
Abstract: GCB1000-U GCB2000 GCB3000 GCB3000-M
Text: Fiber Optic Tool Kits GCB1000, GCB2000 and GCB3000 Fiber Optic CleanBlast Cleaning Systems for Fiber Optic Connectors n Faster, More Effective and Less Costly than using Swabs or other Cleaning Methods n Excellent at Removing–Instead of Spreading–Debris
|
Original
|
PDF
|
GCB1000,
GCB2000
GCB3000
MIL-PRF-29504
GCB1000
GCB1000-U
GCB3000
GCB3000-M
|
M24792A
Abstract: M28840/17
Text: MIL-PRF-28876 QPL and MIL-DTL-28840 QPL U.S. Navy Approved Connectors and Accessories United States United Kingdom Germany France Nordic First Edition • September 2011 Italy Spain Japan All Dressed Up with Nowhere To Go? Glenair Rapid-Response Manufacturing
|
Original
|
PDF
|
MIL-PRF-28876
MIL-DTL-28840
M29504
D-61449
M24792A
M28840/17
|
FCB-IBC12-10
Abstract: MSDS SSI CLEANING SOLVENT FBPT-U25M FCR-001 FCR-CLN-01 FBP-SM03-C FCB-IBC25-10 coil cord ibc25 FBPT-U25MA
Text: COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS Fiber Inspection and Cleaning Kits Key Features • Complete solution for inspecting and cleaning fiber connectors in a single kit • Easily inspect and clean both sides of fiber connections • Crisp, clear fiber end face images for detailed visual
|
Original
|
PDF
|
|
ferrule crimper pull test table
Abstract: ferrule crimper pull test Kester sn62 tinning AMPLIMITE 408-6923 sheet metal press bending machine Tyco manual Semi-automatic for crimping 408-8040 tyco USB connector 90713-1 SN60
Text: Application Specification 114- 40054 Universal Serial Bus USB Connectors NOTE i 29 OCT 09 Rev A All numerical values are in metric units [with U.S. customary units in brackets]. Dimensions are in millimeters [and inches]. Unless otherwise specified, dimensions have a tolerance of +0.13 [+.005] and angles have a tolerance of +2_.
|
Original
|
PDF
|
|
S5 100 B112 MT RELAY
Abstract: CK 66 UL 94V-0 LCD sh 0357 94v-0 c225t F8212 panduit standoff RF based remote control robot circuit diagram of incubator D1148 burndy Y35 crimping tool manual
Text: ELECTRICAL SOLUTIONS A. System Overview Click on the logo above to go to www.panduit.com up to date product information find a local distributor technical information Section Index B1. Cable Ties A. System Overview B2. Cable Accessories B. Bundle B3. Stainless
|
Original
|
PDF
|
SA-NCCB51
S5 100 B112 MT RELAY
CK 66 UL 94V-0 LCD
sh 0357 94v-0
c225t
F8212
panduit standoff
RF based remote control robot
circuit diagram of incubator
D1148
burndy Y35 crimping tool manual
|
Panduit - CMDSAQLCZBL
Abstract: manual legrand 037 71 schematic diagram RCA to HDMI project 24 fiber mtp array polarity Thomas & Betts colored - keyed terminals
Text: PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems SECTION INDEX Click on any section below to go to that portion for a detailed Table of Contents Table of Contents Click on the logo above to go to www.panduit.com up to date product information find a local distributor
|
Original
|
PDF
|
SA-ELCB10
Panduit - CMDSAQLCZBL
manual legrand 037 71
schematic diagram RCA to HDMI project
24 fiber mtp array polarity
Thomas & Betts colored - keyed terminals
|
NAS1388
Abstract: bit3501 Boss White pipe jointing compound NAS1388 SPLICE UL 486 tables MS25036 burndy Y35 crimping tool manual MR1511 burndy connector BIT4 UNITAP CONNECTOR BS-2028
Text: www.fciconnect.com BURNDY PRODUCTS EC&M Catalog Experience. Technology. Answers. CALL 1-800-346-4175 FOR YOUR LOCAL SALES REPRESENTATIVE Quebec & Eastern Ontario 1-800-387-6487 English 1-800-361-6975 (French) Ontario, Atlantic & Western Canada 1-800-387-6487 (English)
|
Original
|
PDF
|
ECM-07
YS40FXB
YS44A1105
YS44FXB
YS4CA1105
YS6CA1105
YS8CA1105
YSCM104
YSCM133
YSCM167
NAS1388
bit3501
Boss White pipe jointing compound
NAS1388 SPLICE
UL 486 tables
MS25036
burndy Y35 crimping tool manual
MR1511
burndy connector BIT4 UNITAP CONNECTOR
BS-2028
|