Text: CBI All In One UPS Power Solutions CBI All In One UPS Power Solutions combine the requirements for several applications in just one device which can be used as power supply unit, battery charger, battery care module or backup module. The available power is automatically distributed among load and battery, while supplying power to the load
|
Original
|
|
PDF
|
CB12245A
Abstract: No abstract text available
Text: Features: CB12245A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 12 VDC; 24 VDC switch select • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd (option) • Automatic diagnostic of battery status. Charging
|
Original
|
CB12245A
E353241
CB12245A
|
PDF
|
CBI123A
Abstract: No abstract text available
Text: CBI123A DC UPS Features: • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 12 VDC; 3 A Output: Battery charging 12 VDC; 3 A Suited for the following battery types:
|
Original
|
CBI123A
CBI123A
|
PDF
|
CB1235A
Abstract: No abstract text available
Text: Features: CB1235A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 24 VDC; 35 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB1235A
CB1235A
|
PDF
|
CB123A
Abstract: No abstract text available
Text: Features: CB123A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 12 VDC; 3 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB123A
CB123A
|
PDF
|
CBI126A
Abstract: No abstract text available
Text: Features: CBI126A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 12 VDC; 6 A Output: Battery charging 12 VDC; 6 A Suited for the following battery types:
|
Original
|
CBI126A
CBI126A
|
PDF
|
CBI245A
Abstract: No abstract text available
Text: Features: CBI245A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 24 VDC; 5 A Output: Battery charging 24 VDC; 5 A Suited for the following battery types:
|
Original
|
CBI245A
EN60950
UL1950
EN54-4
89/336/EEC
DIN41773
CBI245A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Features: CBI2801224A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 12 VDC; 15 A / 234VDC; 10A Output: Battery charging 12 VDC; 15 A / 24VDC; 10A
|
Original
|
CBI2801224A
234VDC;
24VDC;
|
PDF
|
CB1210A
Abstract: No abstract text available
Text: Features: CB1210A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 12 VDC; 10 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB1210A
CB1210A
|
PDF
|
CB126A
Abstract: No abstract text available
Text: Features: CB126A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 12 VDC; 6 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB126A
CB126A
|
PDF
|
CB243A
Abstract: No abstract text available
Text: Features: CB243A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 24 VDC; 3 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB243A
CB243A
|
PDF
|
24V lead acid battery charger circuit
Abstract: No abstract text available
Text: DIN Rail Power Supplies Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of engineering, manufacturing and sales personnel to provide the highest quality
|
Original
|
5150A
24V lead acid battery charger circuit
|
PDF
|
CBI243A
Abstract: No abstract text available
Text: Features: CBI243A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 24 VDC; 3 A Output: Battery charging 24 VDC; 3 A Suited for the following battery types:
|
Original
|
CBI243A
CBI243A
|
PDF
|
CBI2410A
Abstract: No abstract text available
Text: Features: CBI2410A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 24 VDC; 10 A Output: Battery charging 24 VDC; 10 A Suited for the following battery types:
|
Original
|
CBI2410A
CBI2410A
|
PDF
|
|
CB245A
Abstract: No abstract text available
Text: Features: CB245A Battery Charger • Input: Single-phase 115 - 230 -277 VAC • Output: Battery charging 24 VDC; 5 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB245A
CB245A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Features: CBI2801224B DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 230 - 500 VAC Output Load: power supply 12 VDC; 15 A / 24VDC; 10A Output: Battery charging 12 VDC; 15 A / 24VDC; 10A
|
Original
|
CBI2801224B
24VDC;
|
PDF
|
CBI1210A
Abstract: No abstract text available
Text: Features: CBI1210A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 12 VDC; 10 A Output: Battery charging 12 VDC; 10 A Suited for the following battery types:
|
Original
|
CBI1210A
CBI1210A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Features: CBI2803648A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 36/48VDC; 7/5A Output: Battery charging 36/48VDC; 7/5A Suited for the following battery types:
|
Original
|
CBI2803648A
36/48VDC;
|
PDF
|
CBI2420A
Abstract: No abstract text available
Text: Features: CBI2420A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 24 VDC; 20 A Output: Battery charging 24 VDC; 20 A Suited for the following battery types:
|
Original
|
CBI2420A
CBI2420A
|
PDF
|
CBI1235A
Abstract: No abstract text available
Text: Features: CBI1235A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 12 VDC; 35 A Output: Battery charging 12 VDC; 35 A Suited for the following battery types:
|
Original
|
CBI1235A
CBI1235A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Features: CB2410A Battery Charger • Input: Single-phase 115 - 230 - 277 VAC • Output: Battery charging 24 VDC; 10 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB2410A
|
PDF
|
CBI485A
Abstract: No abstract text available
Text: Features: CBI485A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 48VDC; 5A Output: Battery charging 48VDC; 5A Suited for the following battery types:
|
Original
|
CBI485A
48VDC;
CBI485A
|
PDF
|
Untitled
Abstract: No abstract text available
Text: Features: CB2420A Battery Charger • Input: Single-phase 115 - 277 VAC • Output: Battery charging 24 VDC; 20 A • Suited for the following battery types: Open Lead Acid, Sealed Lead Acid, lead Gel and Ni-Cd option • Automatic diagnostic of battery status. Charging
|
Original
|
CB2420A
|
PDF
|
CBI4810A
Abstract: No abstract text available
Text: Features: CBI4810A DC UPS • • • • • • • • INPUT OUTPUT PROTECTION LOAD OUTPUT BATTERY OUTPUT OTHERS Input: Single-phase 115 - 277 VAC Output Load: power supply 48VDC; 10A Output: Battery charging 48VDC; 10A Suited for the following battery types:
|
Original
|
CBI4810A
48VDC;
CBI4810A
|
PDF
|