Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    COPPER OVERHEAD Search Results

    COPPER OVERHEAD Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-DSDMDB09MF-010 Amphenol Cables on Demand Amphenol CS-DSDMDB09MF-010 9-Pin (DB9) Deluxe D-Sub Cable - Copper Shielded - Male / Female 10ft Datasheet
    CS-DSDMDB15MF-002.5 Amphenol Cables on Demand Amphenol CS-DSDMDB15MF-002.5 15-Pin (DB15) Deluxe D-Sub Cable - Copper Shielded - Male / Female 2.5ft Datasheet
    CS-DSDMDB15MM-025 Amphenol Cables on Demand Amphenol CS-DSDMDB15MM-025 15-Pin (DB15) Deluxe D-Sub Cable - Copper Shielded - Male / Male 25ft Datasheet
    CS-DSDMDB25MM-010 Amphenol Cables on Demand Amphenol CS-DSDMDB25MM-010 25-Pin (DB25) Deluxe D-Sub Cable - Copper Shielded - Male / Male 10ft Datasheet
    CS-DSDMDB37MM-002.5 Amphenol Cables on Demand Amphenol CS-DSDMDB37MM-002.5 37-Pin (DB37) Deluxe D-Sub Cable - Copper Shielded - Male / Male 2.5ft Datasheet

    COPPER OVERHEAD Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    burndy Y35 DIE SET

    Abstract: burndy die set Y35 burndy Y35 burndy 8 pin CONNECTOR Burndy Y35 die burndy MD6 u705 y35 burndy burndy CONNECTOR 124 Burndy
    Text: BURNDY Overhead TYPE YE-LH HYSEALPLUG Terminal Plug for Copper Oil and water-tight terminal with shrouded, tin-plated, copper barrel and brazed plug. Recommended for terminating insulated copper conductor at cutout, transformer and arrestor; or for joining insulated copper riser


    Original
    PDF YE2C-LH128 YE2C-LH129 YE25-LH97 YE26-LH88 YE26-LH89 YE28-LH128 YE31-LH96 YE34-LH119 YE34-LH120 Y48BH burndy Y35 DIE SET burndy die set Y35 burndy Y35 burndy 8 pin CONNECTOR Burndy Y35 die burndy MD6 u705 y35 burndy burndy CONNECTOR 124 Burndy

    insulated cable lugs

    Abstract: pilc Ansi C119 4 CI-22A CIR-22 25644 CIR-21 42229 UL 486A OS-0020
    Text: Copper Connectors 149 Copper/Aluminum Connectors 151 Copper Lugs 152 Copper/Aluminum Lugs 155 Oil Seal Lugs 157 SC Series Stem Connectors 157 CP Parallel Clamp 158 CI Series Connectors 159 CI-A Series Connectors 160 CI-T Series Connectors 160 CIR Series Connectors


    Original
    PDF 2000T C-119 2000T-CU insulated cable lugs pilc Ansi C119 4 CI-22A CIR-22 25644 CIR-21 42229 UL 486A OS-0020

    Untitled

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Code Conductor, Thin Wall, Tin-Plated, CTAPF • For copper-to-copper tapping splicing or pigtailing • Wide wire range-taking capability minimizes inventory requirements • Color-coded for proper crimp


    Original
    PDF CT-2930/LE CTAPF2/0-12TP-Q SA-NCCB51 CT-930, CT-2930/L,

    Untitled

    Abstract: No abstract text available
    Text: Overhead Conductors Electric Utility Dead Soft Annealed DSA Copper Clad Steel (CCS) Grounding Conductor Product Construction: Complete Conductor: Features and Benefits: Dead Soft Annealed (DSA) Copper Clad Steel (CCS) conductors are concentric-lay-stranded. The CCS


    Original
    PDF 46X39 46X40 46X41 46X42 46X43 46X44

    Untitled

    Abstract: No abstract text available
    Text: BURNDY Overhead TYPE YCR-R-G HYSPLICE Jumper Sleeve Reducer for ACSR, AAAC and Aluminum to Copper. Heavy-walled aluminum sleeve designed to connect all aluminum or ACSR to copper conductors, in all service conditions encountered in transmission and distribution. Sleeve


    Original
    PDF YCR25RG6 YCR26RG2 YCR26RG3 YCR27RG5 YCR27RG6 YCR28RG5 YCR28RG6 YCR28RG7 YCR28RG8 YCR291RG2

    Untitled

    Abstract: No abstract text available
    Text: BURNDY Overhead TYPES YDS-KT & YDS-F HYSPLICE Full Tension Sleeve for Copperweld-Copper Full-tension HYSPLICE™ made of pure copper tubing. Type YDS-KT is tapered to provide gradual transition of stress on Type "A" conductor. HYSPLICE™ Type YDS-F is


    Original
    PDF Y60BHU YDS25F YDS26F YDS28F YDS7M10T PT-6515. Y60BHU*

    Untitled

    Abstract: No abstract text available
    Text: Electric Utility Ground Wire Bare Copper Ground Wire Conductor Product Construction: Complete Conductor: Bare copper conductors are compressed concentric-lay-stranded, consisting of one or more layers of wire wrapped helically around a straight round central wire. Each


    Original
    PDF

    Untitled

    Abstract: No abstract text available
    Text: Electric Utility Ground Wire Bare Copper Ground Wire Conductor Product Construction: Complete Conductor: Bare copper conductors are compressed concentric-lay-stranded consisting of one or more layers of wire wrapped helically around a straight round central wire. Each


    Original
    PDF

    1237h

    Abstract: 326d Panduit physical infrastructure systems, Mini-Com panduit 200mm 1225h 1488L CUFB48BL
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Consolidation Point Boxes C. Fiber Optic Systems • Suitable for wall mount and underfloor applications • UL 2043 approved for use in air-handling spaces for copper applications D. Power


    Original
    PDF CUFMB24BL CUFMB24BL 24-port 1237h 326d Panduit physical infrastructure systems, Mini-Com panduit 200mm 1225h 1488L CUFB48BL

    CT-2930

    Abstract: J-STD-607-A
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Flex Conductor, Two-Hole, Long Barrel with Window Lug C. Fiber Optic Systems For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors • Meets J-STD-607-A requirements for


    Original
    PDF J-STD-607-A LCCX500-38D-6 LCCX650-12-6 SA-NCCB51 CT-2930

    SA-NCCB51

    Abstract: "Power over Ethernet"
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Code Conductor, Two-Hole, Long Barrel with Window Lug C. Fiber Optic Systems For Use with Stranded Copper Conductors E. Zone Cabling F. Wireless W HOLE SPACING HOLE SPACING G. Outlets INSPECTION


    Original
    PDF J-STD-607-A ba0-38DW-6 LCC750-12W-6 LCC750-38DW-6 SA-NCCB51 "Power over Ethernet"

    minijack

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Cable Prep Tools C. Fiber Optic Systems • Copper Wire Snipping Tool CWST cuts conductors flush for improved performance D. Power over Ethernet • Adjustable Cable Jacket Stripping Tool (CJAST) strips


    Original
    PDF SA-NCCB51. minijack

    SE140

    Abstract: simel CONNECTORS amp quality crimping handbook simel simel xct AUTOPRESS 120 xct 240 cable lugs simel CONNECTORS CTN autopress SAS Cable
    Text: Hydraulic Crimping Tool with rechargeable battery AUTOPRESS U120C AUTOPRESS U120C is designed for hexagon crimping and deep stepped indentation of the following connectors: – “C”, from C10 to C50 – XCT, XCT.C, XCT.EQ copper tubular lugs and XG7T copper joint sleeves from 6 to 300


    Original
    PDF U120C U120C DIN46235 240mm² F-21220 SE140 simel CONNECTORS amp quality crimping handbook simel simel xct AUTOPRESS 120 xct 240 cable lugs simel CONNECTORS CTN autopress SAS Cable

    JFM38

    Abstract: hx 740
    Text: Intel Ethernet Controller I210 Datasheet LAN Access Division LAD Features: • • • • • • • • Small package: 9 x 9 mm PCIe v2.1 (2.5 GT/s) x1, with Switching Voltage Regulator (iSVR) Integrated Non-Volatile Memory (iNVM) Three single port SKUs: SerDes, Copper, Copper IT


    Original
    PDF ECMA-393 JFM38 hx 740

    GPL16

    Abstract: GPL-16-X GPL-34-3
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Grounding Clamp, U-Bolt, Bronze C. Fiber Optic Systems D. Power over Ethernet • Used to ground copper conductor parallel or at a right angle to a rod, tube, or pipe • Made from high strength, electrolytic cast bronze


    Original
    PDF 25ength, GPL16 GPL-16-X GPL-34-3

    Untitled

    Abstract: No abstract text available
    Text: BURNDY Overhead COMPRESSION TERMINALS & ACCESSORIES Compression terminals are used to make convenient and reliable connections to switch pads, transformers, and other electrical equipment. They accommodate either copper, aluminum, ACSR, ACAR, Alumoweld, or


    Original
    PDF YCA25-2N YCA26-2N YCA27-2N YCA28-2N YCAB28-4N YCA29-2N YCA30-2N YCA31-2N YCA32-2N YCAB32-4N

    Mining Cable Engineering Handbook

    Abstract: No abstract text available
    Text: Mining Cable Engineering Handbook 2nd Edition Table of Contents 1. GENERAL PROPERTIES OF COPPER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pg. 1 1.1 Resistance to Annealing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pg. 1


    Original
    PDF INS-0084-0908 Mining Cable Engineering Handbook

    Untitled

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Cable Tie Mounts C. Fiber Optic Systems D. Power over Ethernet E. Zone Cabling F. Wireless G. Outlets H. Media Distribution I. Physical Infrastructure Management J. Overhead & Underfloor


    Original
    PDF TMEH-S10-C100, TMEH-S10-C109

    burndy Y35 DIE SET

    Abstract: burndy KC26 burndy KC34J12T13 burndy Y750 KC34J12T13 YA26 BURNDY burndy die set Y35 KC22J12T13 burndy grounding terminal burndy Y35
    Text: BURNDY Overhead TYPE KC22J12T13, EQC632C TRANSFORMER GROUND CONNECTORS For Copper Type EQC632C Fits all standard EEI-NEMA distribution transformers as a tank grounding terminal. CATALOG NUMBER KC22J12T13 KC26 KC34J12T13 EQC632C RANGES 8 Sol. - 2 Sol. 2 Sol. - 2/0 Str.


    Original
    PDF KC22J12T13, EQC632C KC22J12T13 KC34J12T13 YAB4C-2LH72 YAB4C-2LH73 YAB2C-2LH74 U25RT burndy Y35 DIE SET burndy KC26 burndy KC34J12T13 burndy Y750 KC34J12T13 YA26 BURNDY burndy die set Y35 KC22J12T13 burndy grounding terminal burndy Y35

    telephone drop-wire

    Abstract: CW1417 drop-wire CAD55M telephone* dropwire delaunay B3 CABLE BT 9151 insulated copper wire 0.5mm
    Text: External 4 Pair Dropwire Telephone Cable Copper wire/Polyethylene insulation/Support Strands/Polyethylene sheathed Dropwire Telephone Cable Complies with BT Specification CW1417 CAD55M Application This cable is designed for overhead distribution lines, typically from a telegraph pole to the customer’s


    Original
    PDF CW1417) CAD55M pF/500m telephone drop-wire CW1417 drop-wire CAD55M telephone* dropwire delaunay B3 CABLE BT 9151 insulated copper wire 0.5mm

    telephone drop-wire

    Abstract: M 180-001 CW1411 telephone* dropwire B3 CABLE
    Text: External 2 Pair Dropwire Telephone Cable Copper wire/Polyethylene insulation/Support Strands/Polyethylene sheathed External Dropwire Telephone Cable Complies with BT Specification CW1411 Application This cable is designed for overhead distribution lines, typically from a telegraph pole to the customer’s


    Original
    PDF CW1411) pF/500m telephone drop-wire M 180-001 CW1411 telephone* dropwire B3 CABLE

    Untitled

    Abstract: No abstract text available
    Text: BURNDY Overhead TYPE YDS-K HYSPLICE Full Tension Sleeve for Copperweld Full-tension HYSPLICE™ designed to exceed the minimum rated breaking strength of, 30% conductivity extra high strength Copperweld, and lower strength conductors. Made of pure copper tubing. Installed with


    Original
    PDF YDS3K10 PT-6515. YTS375E YTS438E Y60BHU*

    threaded rod

    Abstract: Panduit physical infrastructure systems NF4PR84
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems 4x4 and 6x4 FiberRunner Mounting Brackets C. Fiber Optic Systems Part Number D. Power over Ethernet E. Zone Cabling FR6TRBE12 FR6TRBE12 FR6TRBE58 FR6TRBE12M FR6TRBE58M FR6TRBE58 FR6TRBE12M


    Original
    PDF FR6TRBE12 FR6TRBE58 FR6TRBE12M FR6TRBE58M FRRMBNF58 FR4PRB58 threaded rod Panduit physical infrastructure systems NF4PR84

    Untitled

    Abstract: No abstract text available
    Text: A. System Overview PHYSICAL INFRASTRUCTURE SYSTEMS B. Copper Systems Self-Laminating Fiber Optic Cable Marker Tags C. Fiber Optic Systems Material Chart Material Rigid Vinyl, Self-Laminating D. Power over Ethernet Print Method Pre-Printed Temperature Range


    Original
    PDF PPS0710G001 PPS1014G002 PPS0710G020 PPS1209G010 PPS1209G012 PPS1209G011