    Part ECAD Model Manufacturer Description Download Buy
    DFE2016CKA-1R0M=P2 Murata Manufacturing Co Ltd Fixed IND 1uH 1800mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN55NJ0HD Murata Manufacturing Co Ltd Fixed IND 55nH 1500mA POWRTRN Visit Murata Manufacturing Co Ltd
    LQW18CNR56J0HD Murata Manufacturing Co Ltd Fixed IND 560nH 450mA POWRTRN Visit Murata Manufacturing Co Ltd
    DFE322520F-2R2M=P2 Murata Manufacturing Co Ltd Fixed IND 2.2uH 4400mA NONAUTO Visit Murata Manufacturing Co Ltd
    LQW18CN4N9D0HD Murata Manufacturing Co Ltd Fixed IND 4.9nH 2600mA POWRTRN Visit Murata Manufacturing Co Ltd

    CONTACTOR COILS 220V Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    IEC60947-4-1

    Abstract: No abstract text available
    Text: De finit e Purpose Cont a c t ors 3 -pole Type CGDP • • • • • • Definite Purpose Contactor Switching up to 40A inductive, 50A resistive Coils up to 575VAC, 50/60 Hz cRUus, CSA, CE, and RoHS Faston standard or box lug terminals Available configured as reversing definite


    Original
    PDF 575VAC, CGDP30XX CGDP30XX CGDPR30XX IEC60947-4-1

    CA3-9-10

    Abstract: Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10
    Text: Accessories – Field Installable CA7 Contactors Contact Block Description NO NC Contact Arrangement Standard Contacts Catalog For use with. Number Bifurcated Contacts Catalog Price Number ➋ Price 51 61 2 CA7 all CS7-PV-02 27 CS7-PVB-02 42 CA7-30.97-✱-00


    Original
    PDF CS7-PVB-02 CA7-PV-02 CA7-PVB-02 CS7-PV-11 CS7-PVB-11 CA7-30. CA7-PV-11 CA7-PVB-11 CA7-PV-S11 CA7-PVB-S11 CA3-9-10 Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Text: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    PDF NFC63-110, VDE0660, BS5424, JEM1038 IEC60947-4 VDE 0660 iec 158-1 NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660

    Sprecher Schuh LE 2-16

    Abstract: TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719
    Text: Contactors - AC Coil Four Pole - Series CA7 A Non-Reversing, Four Pole Contactors With AC Coil, Series CA7 Open type only Contactors Ratings for Switching AC Motors (AC2 / AC3 / AC4) Open Type Contact Configuration, Ie [A] kW (50 Hz) UL/CSA HP (60 Hz) Main Pole Catalog


    Original
    PDF CA7-9-M40- CA7-9-M31- CA7-9-M22- CA7-12-M40- CA7-12-M31- CA7-12-M22- Sprecher Schuh LE 2-16 TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719

    westinghouse to Cutler-Hammer cross reference

    Abstract: WESTINGHOUSE life line contactor 927566 Cutler-Hammer type m RELAY Cutler-Hammer 9586 westinghouse contactor westinghouse transistor cross reference WESTINGHOUSE scr WESTINGHOUSE motor life line Westinghouse SCR cross reference
    Text: Motor Control Motor Control 13 Motor Control Contactors, Starters and Brakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Adjustable Frequency AC Drives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Synchronous . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 CA08100014Eâ V12-T13-1 IB48008 IB48009 RP48J01TE RPD8855S westinghouse to Cutler-Hammer cross reference WESTINGHOUSE life line contactor 927566 Cutler-Hammer type m RELAY Cutler-Hammer 9586 westinghouse contactor westinghouse transistor cross reference WESTINGHOUSE scr WESTINGHOUSE motor life line Westinghouse SCR cross reference

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    PDF GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25

    A425XBX90-120A

    Abstract: MAGNECRAFT WM100A-24D W199BMX-14 A425XBX deltrol WM60A-24D WM100A-120A a275kxx W199AHX-14 60NO-220A
    Text: Your Contact for Relays SECTION POWER RELAYS & CONTACTORS 15 TO 300 AMPERES 3 POWER & MDR RELAYS MDR 199 RELAY SERIES ISO 9002 L W H 2.43-3.12 x 2.50 x 2.53 PANEL MOUNT, OPEN STYLE CONSTRUCTION L W H SEE PAGE XX MERCURY DISPLACEMENT RELAY MDR UP TO 3 POLES, NO , NC OR COMBINATIONS OF NO & NC


    Original
    PDF RESISTANCE00NO-120A WM100A-240A CFC-720 100NO-220A WM100A-24D CFC-723 100NO-24D A425XBX90-120A MAGNECRAFT WM100A-24D W199BMX-14 A425XBX deltrol WM60A-24D WM100A-120A a275kxx W199AHX-14 60NO-220A

    schneider LC1-D38

    Abstract: LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09
    Text: References TeSys contactors For motor control up to 75 kW at 400 V, in category AC-3 Control circuit: a.c., d.c. or low consumption 810356 3-pole contactors for connection by screw clamp terminals or connectors Standard power ratings of 3-phase motors 50/60 Hz in category AC-3


    Original
    PDF LC1-D09// LC1-D12// LC1-D18// LC1-D25// LC2-DT20. schneider LC1-D38 LC1-D38 LC1-D09 LC1-D123 lc1d128 LC1-D093 LC1D09 schneider LC1-DT25 schneider LC1-D258 schneider LC1-D09

    magnetic Contactor wiring diagrams

    Abstract: 220V coil 30A SPDT RELAY KR3DH-12 KR3DH-24 wiring diagram contactor 40 amp 3 phase Struthers-Dunn relay KR3DH W88UKADX-3 12V 30A SPDT RELAY KR-3DH-24
    Text: SERIES OPEN STYLE - 3 POLE, 30 AMP POWER RELAY 425 The series 425 Power relay is capable of handling up to 30 Amps and 1 Hp Loads. The Series 425 has sufficient spacing to allow for 600 Vac contact ratings . The Design features a enclosed coil, Screw Terminals and Silver Cadmium Oxide contacts as standard.


    Original
    PDF 30/DC 120-240/AC 208-240/AC 277/AC 600/AC 101HXX 102HXX 103HXX magnetic Contactor wiring diagrams 220V coil 30A SPDT RELAY KR3DH-12 KR3DH-24 wiring diagram contactor 40 amp 3 phase Struthers-Dunn relay KR3DH W88UKADX-3 12V 30A SPDT RELAY KR-3DH-24

    C25DRF340

    Abstract: C25DRJ350 C25DNJ250 C25GNF390
    Text: Definite Purpose Contactors and Starters 0–40A Compact Contactor 4.1 Product Overview—Contactors and Starters Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF V5-T4-17 V5-T4-20 V5-T4-23 V5-T4-30 V5-T4-38 V5-T4-46 V5-T4-49 V5-T4-52 V5-T4-55 V5-T4-57 C25DRF340 C25DRJ350 C25DNJ250 C25GNF390

    IEC/EN60947-4-1

    Abstract: contactor coils 220v timer contactor contactor coils 24v contactor coils 415v a1218 380Vac A1725 P1016 contactor coils 415v Ac
    Text: Introducing P&B PBC series IEC-Type Contactors and Accessories P&B PBC Series IEC-Type Contactors and Accessories KEY FEATURES DESCRIPTION Contactors offer three pole Compact AC coil contactors in three frame widths offer ratings from 9 amps to 80 amps AC-3 per IEC 947-4 .


    Original
    PDF PBT-322 PBT-324 IEC/EN60947-4-1 contactor coils 220v timer contactor contactor coils 24v contactor coils 415v a1218 380Vac A1725 P1016 contactor coils 415v Ac

    IEC 947 EN 60947

    Abstract: Allen-Bradley contactors 100s Allen-Bradley 100-FSD250 lr13908 100-FSC280 100-SA10 IEC 158-1 VDE 0660 DIN19240 700S-CF440DJC Allen-Bradley contactor 100s-c09
    Text: Bulletin 100S-C/104S-C Safety Contactors Bulletin 700S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin 100S-C/104S-C Safety Contactors Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF 100S-C/104S-C 700S-CF 100S-C/104S-C S-C3004C. C8504C 100S-C09404C. C23404C 100S-C09304C. IEC 947 EN 60947 Allen-Bradley contactors 100s Allen-Bradley 100-FSD250 lr13908 100-FSC280 100-SA10 IEC 158-1 VDE 0660 DIN19240 700S-CF440DJC Allen-Bradley contactor 100s-c09

    IEC 158-1 VDE 0660

    Abstract: IEC 158-1 bs5424 mte relay mte max04 mte thermal overload relay axt1 overload mte max0 660VAC BS5424 IEC 158-1 VDE 0660
    Text: Issued November 1994 018-433 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    PDF 220/240V 24Vdc 415/440V IEC 158-1 VDE 0660 IEC 158-1 bs5424 mte relay mte max04 mte thermal overload relay axt1 overload mte max0 660VAC BS5424 IEC 158-1 VDE 0660

    IEC 158-1

    Abstract: bs5424 IEC 158-1 VDE 0660 axc1 axc3 mte max0 mte relay BS5424 IEC 158-1 VDE 0660 mte thermal overload relay VDE 0660 iec 158-1
    Text: Issued March 1997 232-4831 Data Pack B The MTE range of overload relays, control relays, contactors and accessories Data Sheet A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    PDF 220/240V 24Vdc 415/440V IEC 158-1 bs5424 IEC 158-1 VDE 0660 axc1 axc3 mte max0 mte relay BS5424 IEC 158-1 VDE 0660 mte thermal overload relay VDE 0660 iec 158-1

    100-FSC280

    Abstract: 100-SA10 allen bradley IEC 60947-5-1 TAG 8922 100-FSV136 100-FSV55 VDE 0660 iec 158-1 100-SB10 700S-CF440ZJC 700S-CF440DC
    Text: Contactors & Control Relays Safety Control Relays 700S-CF Specifications Conformity to Standards IEC 60947-5-1 IEC 60947-5-1 Annex L — Special Requirements for Mechanically Linked Contact Elements EN50011, EN50005, EN50022 UL 508 VDE 0660 Description Bulletin 700S-CF Safety Control Relays provide mechanically linked,


    Original
    PDF 700S-CF EN50011, EN50005, EN50022 700S-CF co180 100S-D210-EI. 100S-D420-EI 100S-D630-EI. 100S-D860-EI 100-FSC280 100-SA10 allen bradley IEC 60947-5-1 TAG 8922 100-FSV136 100-FSV55 VDE 0660 iec 158-1 100-SB10 700S-CF440ZJC 700S-CF440DC

    westinghouse to Cutler-Hammer cross reference

    Abstract: 10000 watt stabilizer transformer winding formula MN03305001E AN16BN AN16UN0 N101DS2K3A AN16TN0 N101BS0A3A CN15GN3 N05NCXRD3A
    Text: Tab33.book Page 1 Sunday, September 21, 2008 10:27 PM NEMA Contactors & Starters A-1 NEMA Contactors & Starters July 2008 Contents CA08102002K For more information visit: www.EatonCanada.ca Description Page IT. Electro-Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF Tab33 CA08102002K westinghouse to Cutler-Hammer cross reference 10000 watt stabilizer transformer winding formula MN03305001E AN16BN AN16UN0 N101DS2K3A AN16TN0 N101BS0A3A CN15GN3 N05NCXRD3A

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    PDF 380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v

    IEC 158-1 VDE 0660

    Abstract: mte thermal overload relay bs5424 auto relay 12v 100A mte relay IEC 158-1 mte max0 axt1 overload VDE 0660 iec 158-1 axc1
    Text: Issued November 1994 B18433 The MTE range of overload relays, control relays, contactors and accessories A comprehensive range of four and three pole control relays and contactors with associated accessories including overload relays, replacement coils and


    Original
    PDF B18433 BS5424, VDE0660 660Vac 600Vac IEC 158-1 VDE 0660 mte thermal overload relay bs5424 auto relay 12v 100A mte relay IEC 158-1 mte max0 axt1 overload VDE 0660 iec 158-1 axc1

    IEC 947-5-1 VDE 0660

    Abstract: wiring diagram contactor relay contactor wiring diagrams contactor coils 24v contactor coils 230v DC contactor 220V J7KNA-09-10-24 contactor 4pole AC 230V to convert 220V DC power control J7KNA-AR-31
    Text: Mini Contactor Relays 4-pole ole Main contactor • AC & DC operated • 4-, 6- and 8-pole versions in different configurations • Positively guided contacts • Screw fixing and snap fitting 35 mm DIN N rail ) • Rated current = 10A ( Ith ) • Suitable for electronic devices ( DIN 19240 )


    Original
    PDF J73KN-A. J507-E2-01 IEC 947-5-1 VDE 0660 wiring diagram contactor relay contactor wiring diagrams contactor coils 24v contactor coils 230v DC contactor 220V J7KNA-09-10-24 contactor 4pole AC 230V to convert 220V DC power control J7KNA-AR-31

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    PDF 380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor

    IEC 947-5-1 VDE 0660

    Abstract: relay contactor wiring diagrams J73KN-A-40 J73KN-A-22 contactor coils 415v contactor coils 24v VDE 0660 AC240V AC24V AC440V
    Text: Mini Contactor Relays 4-pole J7KNA-AR Main contactor • AC & DC operated • 4-, 6- and 8-pole versions in different configurations • Positively guided contacts • Screw fixing and snap fitting 35 mm DIN rail ) • Rated current = 10A ( Ith ) • Suitable for electronic devices ( DIN 19240 )


    Original
    PDF J73KN-A. J507-E2-01 IEC 947-5-1 VDE 0660 relay contactor wiring diagrams J73KN-A-40 J73KN-A-22 contactor coils 415v contactor coils 24v VDE 0660 AC240V AC24V AC440V

    star delta starter single line drawing

    Abstract: bf65 BFK12 T2D45 BF65C BGP09 BFK18 321 D012 electromechanical relay BFK09 BFK32
    Text: 03_Capitolo_03GB.qxd 3-03-2009 10:57 Pagina 1 3 CONTACTORS PAGE 3-8 FOUR-POLE CONTACTORS • • • • • Ith ratings in AC1 duty at ≤40°C: 20 to 1600A • Power ratings in AC1 400V duty: 14 to 950kW • AC, DC and DC low-consumption control coil. Ith ratings in AC1 duty at ≤40°C: 16 to 1600A


    Original
    PDF 950kW 335kW 60kvar B1250 B1600 BA1588 B115-B145-B180 BA1589 star delta starter single line drawing bf65 BFK12 T2D45 BF65C BGP09 BFK18 321 D012 electromechanical relay BFK09 BFK32

    lc1d12008

    Abstract: LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80
    Text: Contactors d 3-pole contactors for motor control, 9 to 95 A Utilisation category AC-3 Control circuit : a.c. Dimensions, mounting : pages 1/44 to 1/48 References Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 θ ≤ 55 °C 1 Rated operational


    Original
    PDF LC1-D0900ii LC1-D0910ii LC1-D0901ii LC1-D1200ii LC1-D1210ii LC1-D1201ii LC1-D1800ii LC1-D1810ii LC1-D1801ii LC1-D2500ii lc1d12008 LC1D40008 lc1-d25008 LC1D12004 LC1-D1810 lp1d1210 telemecanique LC1-d18 LC2D0901 LA1-DN22 telemecanique contactor LC1D80

    telemecanique contactor catalogue

    Abstract: telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D
    Text: Telemecanique D contactors and overload relays D115-59kw AC3 D150-80kw AC3 Telemecaniques’ D range is the world’s number one in contactors. Two new D range contactors are now available, expanding the range to 80kw AC3 for motor control and 200A AC1 for distribution


    OCR Scan
    PDF D115-59kw D150-80kw telemecanique contactor catalogue telemecanique LC1D115 schneider contactor catalogue LC1-D150 LC1-D115 DIMENSIONS LA9-D115603 lc1d11500 CONTACTOR LC1-D115 telemecanique catalogue contactor telemecanique LC1D