rrm ASEA
Abstract: RRM17 rK-11 ASEA ASEA protection relay relay 5 volt rr ASEA 40307
Text: Under-vdltage relay under-voltage protect1.0n .Three-phase .Comprises .Used RROTC 2 silicon semiconducto with neutral for single-phase .Requires no auxiliary .Tripping carried out over .Two-seat plug-in unit value for three-phase j .Operates of 1 .I design
|
Original
|
PDF
|
RRM17:
rrm ASEA
RRM17
rK-11 ASEA
ASEA protection relay
relay 5 volt
rr ASEA
40307
|
ASEA current transformer imbd
Abstract: ASEA EG 20 ASEA relay - unbalance relay ASEA imbd ASEA unbalance relay asea transformer current ASEA RI asea ri 5A relay
Text: ASEA INFORMATION Unbalance Protection Type RYBIA RK 60-337 E Reg. 7456 for Series capacitors • DESCRIPTION 07 RELAY PROTECTION ASEA capacitor units consist of a number of parallel connected GENERAL elements each of them in series with a built-in fuse. If a short
|
OCR Scan
|
PDF
|
53-8/ul?
53-10yuF
ASEA current transformer imbd
ASEA EG 20
ASEA relay - unbalance relay
ASEA imbd
ASEA unbalance relay
asea transformer current
ASEA RI
asea ri 5A relay
|
asea time-lag relay RI
Abstract: asea relay RIS rma 16 relay ASEA RHGA 8 ASEA RIs asea ridi asea over current relay asea relay RI RCA RF Catalogue asea relay
Text: i ASEA Catalogue RK 93 E Edition 1 May 1966 File R Part 2 Frames and connectors for relays Contents: Front terminals Extension bolts and terminal screws Flush mounting frames Blanking plates Adapting frames Relay testing block RTNP P -2 3 4 9 9 10 ASEA Front terminals
|
OCR Scan
|
PDF
|
a5203
asea time-lag relay RI
asea relay RIS
rma 16 relay
ASEA RHGA 8
ASEA RIs
asea ridi
asea over current relay
asea relay RI
RCA RF Catalogue
asea relay
|
ASEA generator manual
Abstract: ASEA 34-1 M 160 M 4 asea RK 316 A56A hydropower hydropower plants asea relay RI asea ri relay ASEA E 535 RK 732 - 228
Text: ASEA IriiO'Mu. RK 549-300 E ' • IINFORMATION R eg. FromrfQato Relay Division . T1TR, September 1977 Edition 1 Paga 5626 1 File RK 00“90 1 Section 5 Frequency relay type TFF 60 o Ability to supervise up to seven frequency levels o Dnder- or overfrequency design
|
OCR Scan
|
PDF
|
|
MR 4710
Abstract: RTXP 18 ASEA RXIDE 0022-AA rk 12 e RXIDE43 overcurrent relay inverse normal curves rk 651 25D1 asea time-lag relay RI
Text: ASEA Catalogue RK 65-13 E Edition 1 Fil« » , Part 1 ClOlMiBll iFlLlElXÍ Two or three-phase timeovercurrent protective relays Contarli* General Design Setting Diagrams Installation Ordering Reference publications Cl oj CJ For machines, transformers, cables and
|
OCR Scan
|
PDF
|
21-1G
9Z-10
S-721
MR 4710
RTXP 18 ASEA
RXIDE
0022-AA
rk 12 e
RXIDE43
overcurrent relay inverse normal curves
rk 651
25D1
asea time-lag relay RI
|
RREL 24 Relay
Abstract: RREL 20 Relay RK415 rril 24-15-RRIL rrmj RRIL-23 RK 0313 RRIG Rmj Relay
Text: ASEA Catalogue RK 41-2 E Instantaneous current and voltage relays type RRIL and RREL / For use in sho rt-circuit protections, earth-fault protections etc. frequently in com bination with tim e-lag relays • Are electrom agnetic load capacity ■ with high
|
OCR Scan
|
PDF
|
|
RXIDF 2H
Abstract: RXIDF asea ri 5A relay BROWN BOVERI protection relay rxidf2h RK473 RK473 004 rxidf-2h BROWN BOVERI HE RK65
Text: Catalogue RK 47-11 E Edition 2 , 1&Ê1-03 File Ft, Part 1 ASEA BROWN BOVERi Time-lag overcurrent relay type RX1DF 2H • Starting, instantaneous and defayed operation wftti individual settings . • Reconnectibte to r 0-1,0.2, :0>5 and 1. A o r tar 0.5, -1,2,6 and
|
OCR Scan
|
PDF
|
|
RTXP 18 cutout
Abstract: rk 926 006-aa RXZ21 RK 928 008-AB RK924 RK 924 0001 asea pin terminal RTXG RHGX20 RXZ41 924006
Text: ASEA Catalogue RK 92-10 E Edition 3 September 1980 File R, part 1 Connection and installation parts for COMBIFLEX modular system • Connection parts for up to 10 and 20 A continuous load • Installation parts for construction of apparatus groups and their installation in equipment frames, cases, boxes and
|
OCR Scan
|
PDF
|
|
aeg rsz
Abstract: AEG RSZ 2 aeg rsz 3 AEG T 178 aeg protection relay oerlikon aeg rsz settings cdc 2030 Sprecher Schuh timer R3AS52
Text: RK 40-401 C om parison betw een ASEA tim e -la g o v e r- c u rr e n t re la y type RIDA w ith independent tim e -la g c h a ra c te ris tic and c o rresp o n d in g re la y s of o th er m akes CONFIDENTIAL Reg, 5621,7431 RELAY INFORMATION This c ir c u la r Is intended as a guide to ASEA s a le s re p re se n ta tiv e s
|
OCR Scan
|
PDF
|
40-40IE
aeg rsz
AEG RSZ 2
aeg rsz 3
AEG T 178
aeg protection relay
oerlikon
aeg rsz settings
cdc 2030
Sprecher Schuh timer
R3AS52
|
Relay cf 318 9.0
Abstract: Relay cf 318 ez 741 DM 311 BG 215CN DM 311 BG 35 AB 314a 741 CN 211-DA msta
Text: ASEA Catalogue RK 74-10 E E d itio n 1 February 1£¡73 F ija R, P art 1 Component block type RTXE [c|ô|mTbI with diodes, thermistors or resistors • * * * * Requires no extra space To be mounted at the rear o f the relay terminal base The encapsulated block hermetically
|
OCR Scan
|
PDF
|
|
RXIDE
Abstract: RXIDE43 RXTIE RXIDE41 165-DE rxtie4 474-300 RK474
Text: InlQ'NQ, ASEA INFORMATION FTOfiVDatB RFE, March 1975 Edition 1 Relay Division RK. 4 7 4 -3 0 0 E RBg. Pag 5621 1 File EK 00-90 E Section 4 Time-lag overcurrent relay type RXIDE b - Operating time curves according to B.I Another variant of the R5IDE 4 has been designed. This variant
|
OCR Scan
|
PDF
|
s-721
165-PE
165-XX
SQ-60.
RXIDE43
RXIDE
RXTIE
RXIDE41
165-DE
rxtie4
474-300
RK474
|
rrkn 1108
Abstract: ASEA RRKN asea, electromagnetic 110 v dc relay ASEA RELAY asea RK 316 asea rrkn MS 1307 RK 92-1 E
Text: Catalogue RK 31-1 E ASEA Edition 3 Time-lag relay type RRKN • Time-lag on pick-up; scales: 50—500 ms. 0 .2 -2 s and 1—10 s • For d.c. supply a.c. supply across rectifier • Comprises static components • • Very accurate setting O ccupies one relay seat (40X55 mm)
|
OCR Scan
|
PDF
|
40X55
rrkn 1108
ASEA RRKN
asea, electromagnetic 110 v dc relay
ASEA RELAY
asea RK 316
asea
rrkn
MS 1307
RK 92-1 E
|
rxma1
Abstract: rxtug2h RK 211 025 rxma-1 undervoltage relay 037-AD overvoltage relay Rxotf RK 211 037 440 AB
Text: Catalogue RK 42-16 E ASEA Edition 1 Overvoltage and undervoltage relay type RXEF 2 • S tatic relay that operates fo r voltage variations • Versions fo r d.c. and single-phase a.c. • Separate setting knobs fo r overvoltage and undervoltage operation, 1 0 5 120 % and 8 0 -9 5 % respectively of the
|
OCR Scan
|
PDF
|
037-AD
052-AD.
S-721
rxma1
rxtug2h
RK 211 025
rxma-1
undervoltage relay
overvoltage relay
Rxotf
RK 211 037
440 AB
|
RXIDE
Abstract: RXIDE41 rxtie 4 RXTIE rxtie4 overcurrent relay inverse normal curves asea over current relay rk 427 RXIDE43 "125he" asea directional relay RXPE
Text: Catalogue RK 47-10 E ASEA Edition 1 January 1972 File R, Part 1 Time-lag over-current relay îc ïô I m ïb TT type RXIDE 4 'iFjjjEjxP Registered trade mark Page Time-lag over-current relay type RXIDE 4 81674 2 2 co oo Relay p rotection incorporating tim e-lag over-current relay type RXIDE 4 mounted on a frame (81687
|
OCR Scan
|
PDF
|
|
|
RK 723 007
Abstract: DIODE RK 306 SELECTOR SWITCH ASEA ABG RK 795 001-aa RK741 RK717 CATALOGUE SK 63-1 E ASEA ABG 10 RK795 RK70-10E
Text: C a ta lo g u e R K 70- 10E Edition 1 5930-09 Su persecTes calatog ues R K 7 M O E RK 74-1OE and R K 7 8 -2 E Relay accessories Pushbuttons Component blocks ASEA T h e re lay accesso ries a re used to provide a relay, protective relay or other equip m en t, with
|
OCR Scan
|
PDF
|
RK70-10E
74-1OE
RK78-2E
S-721
i960-Â
RK 723 007
DIODE RK 306
SELECTOR SWITCH ASEA ABG
RK 795 001-aa
RK741
RK717
CATALOGUE SK 63-1 E
ASEA ABG 10
RK795
|
RXKN1
Abstract: rxtda 1 RK 315 L 333-AX electromagnetic 110 v dc relay
Text: ,1 I ASEA ^ k fc fe c t V - f l ' Z i } f £/c j / ' / ^ c Catalogue RK 31-12 E Editibn 2 Time-lag relay type RXKN 1 i¿ ; -j r • Specially designed for protective relays, automatic equipment or industrial use » Time.-laj on pick-up scales: 50-500 ms, 0 .2 -2 s and 1 -1 0 s
|
OCR Scan
|
PDF
|
133-AD
133-AH
133-AS
233-AN
233-AX
RXKN1
rxtda 1
RK 315 L
333-AX
electromagnetic 110 v dc relay
|
RRMH ASEA
Abstract: RRMH rK-11 ASEA ASEA RHGA 8 rrmj4 ASEA EG 20 ASEA RHGA 8 rk 925 0001 asea RRME RK 92-1 E rrmh2
Text: Catalogue RK 9 2 -1 E T H E A S E A PLU G -IN RELAY SYSTEM Relay sets based on tt» ASEA plug-ln system ill easily made up using relays and relay components six case sizes giving from 2 to 42 relay seata. Plug-In relays occupy 1, 2 or 4 relay seats a wide variety of components — auxiliary relays, signal relays and Indicating devices,
|
OCR Scan
|
PDF
|
14-sf
RRMH ASEA
RRMH
rK-11 ASEA
ASEA RHGA 8
rrmj4
ASEA EG 20
ASEA RHGA 8 rk 925 0001
asea RRME
RK 92-1 E
rrmh2
|
rs 307
Abstract: RK 221 025 RXSU 21 bridge rectifier rs 307 asea time-lag relay RI AH 512 RK 211 025 rxtcb1 rs 307 rectifier RXSL 1
Text: Catalogue RK 28-10 E ASEA E ditio n 2 Signal system type RS 4 with flashing lights O c to b e r 1974 File R, Part 1 !| Signal function modules and signal function units • • B u ilt up o f sta n d a rd is e d fu n c tio n m od u G ives fa u lt in d ic a tio n
|
OCR Scan
|
PDF
|
--83--I--
S-721
rs 307
RK 221 025
RXSU 21
bridge rectifier rs 307
asea time-lag relay RI
AH 512
RK 211 025
rxtcb1
rs 307 rectifier
RXSL 1
|
RXIDF 2H
Abstract: asea relay RIS IC 7431 asea ri 5A relay asea over current relay RXIDF rxsga1 asea time-lag relay RI RK651126-EB RK51-10E
Text: Catalogue RK 65-17 E Edition 2 A p r ili 961 File R, Part 1 • Time-overcurrent protective relays • Used as short-circuit and earth-fault re lays for cables, power lines, machines and transformers • independent or inverse time-iag characteristic • One, two and three phase protection with separale m eas
|
OCR Scan
|
PDF
|
21-io
RK65-20E
RK51-10
S-721
RXIDF 2H
asea relay RIS
IC 7431
asea ri 5A relay
asea over current relay
RXIDF
rxsga1
asea time-lag relay RI
RK651126-EB
RK51-10E
|
relay ras 1210
Abstract: asea RRME rrmh2 ASEA RMA16 RRMH RRME 1608 rrMH 2-107 MX 0842 RRMH ASEA rrme1
Text: R K Ii E AUXILIARY RELAYS , . -v lp f f ig g , • several designs > ; .< -,v . • " : ^ • ¿ 5 | 8 ly • heavy-current design • plug-ln lypes i - • types for fixed mounting " - . • suitable fo r tropical conditions £•■■ , v . y ^ - -p * & p .
|
OCR Scan
|
PDF
|
RMX17
RRM17
relay ras 1210
asea RRME
rrmh2
ASEA RMA16
RRMH
RRME 1608
rrMH 2-107
MX 0842
RRMH ASEA
rrme1
|
asea time-lag relay RI
Abstract: asea relay RIS asea ridi asea rvaa ASEA RIs asea relay RI asea type ir harmonic asea ri relay asea relay RIdi RK 0313
Text: C Î? E * JK Catalogue RK 47-1E H iM Edition 2 O ctober 1972 File R, Part 2 Time-lag overcurrent relays with inverse characteristic type Rl, RIS, RIDI and RIDSI • Operating tim e decreasing as the current increases, but practically constant tim e at very high currents.
|
OCR Scan
|
PDF
|
47-1E
asea time-lag relay RI
asea relay RIS
asea ridi
asea rvaa
ASEA RIs
asea relay RI
asea type ir harmonic
asea ri relay
asea relay RIdi
RK 0313
|
BROWN BOVERI Typ STf
Abstract: BROWN BOVERI relay stf RXDHL BROWN BOVERI stf RADHL BROWN BOVERI relay st rxdhl 4 BROWN BOVERI relay type STF BROWN BOVERI relay differential Brown Boveri SERIES 212
Text: ABB # * ü l» 1nfO‘Wü. ILK612-301 INFORMATION FiontfDitB Reg. E P4£6 ASEft B R O W N BOVÊRI RFR, January 1978 Edition 1 Relay Division 7434 1 Pile RK 00-90 E Section 6 Pilot-vire differential relay type RADHL for cables and overhead lines _
|
OCR Scan
|
PDF
|
00-S0
S-721
BROWN BOVERI Typ STf
BROWN BOVERI relay stf
RXDHL
BROWN BOVERI stf
RADHL
BROWN BOVERI relay st
rxdhl 4
BROWN BOVERI relay type STF
BROWN BOVERI relay differential
Brown Boveri SERIES 212
|
BROWN BOVERI HE
Abstract: RXPE 42 rk 511 RXPE47 brown boveri overcurrent relay asea directional relay asea directional relay RXPE RAEPA asea directional relay RXPE 40 Boveri voltage regulator rxpe
Text: Il Hi II *I»IP ASEA B R O W N BOVERI ABB Relays Abstract Application RXPE 47 +65° directional-overcurrent relay B03-3012E Page 1 June 30, 1982 Data subject to change without notice • Voltage-polarized • Operating value constant within a wide polarizing voltage range
|
OCR Scan
|
PDF
|
B03-3012E
B03-9301E
B03-3003E
B03-3010E
B03-3011E
B03-9382E
S-721
BROWN BOVERI HE
RXPE 42 rk 511
RXPE47
brown boveri overcurrent relay
asea directional relay
asea directional relay RXPE
RAEPA
asea directional relay RXPE 40
Boveri voltage regulator
rxpe
|
RK90E
Abstract: overcurrent relay inverse normal curves RRIDE RRIDE41 overcurrent relay inverse RRTIE BS142 RK 92-1 E RK475 asea relay
Text: Catalogue RK 47-3 E EA Edition 1 January 1972 File R, P a rt2 Time-lag over-current relay type RRIDE 4 • Single-phase or three-phase design, 50— 60 Hz • Inverse o r independent tim e-lag char acteristic • A djustable instantaneous operation fo r high ove r-currents
|
OCR Scan
|
PDF
|
|