Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    IEC60947 Search Results

    SF Impression Pixel

    IEC60947 Price and Stock

    WAGO Innovative Connections IEC60947-7-1

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bristol Electronics IEC60947-7-1 79
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote
    New Advantage Corporation IEC60947-7-1 82 1
    • 1 $14.28
    • 10 $14.28
    • 100 $10
    • 1000 $10
    • 10000 $10
    Buy Now

    WAGO Innovative Connections IEC60947-7-2

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bristol Electronics IEC60947-7-2 50
    • 1 -
    • 10 -
    • 100 -
    • 1000 -
    • 10000 -
    Get Quote

    Phoenix Contact IEC60947-7-1

    Distributors Part Package Stock Lead Time Min Order Qty Price Buy
    Bristol Electronics IEC60947-7-1 48 1
    • 1 $12
    • 10 $9
    • 100 $7.5
    • 1000 $7.5
    • 10000 $7.5
    Buy Now

    IEC60947 Datasheets (2)

    Part ECAD Model Manufacturer Description Curated Datasheet Type PDF
    IEC 60947-5-2 Hirschmann Electronics E Series M12 Original PDF
    IEC 60947-5-2 Hirschmann Electronics E Series M8 Cable sockets and plugs with molded-on lead, snap locking Original PDF

    IEC60947 Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    440N-Z2NRS1A

    Abstract: 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP
    Text: Safety Switches Non-Contact Switches Magnetically Coded Specifications MC1 MC2 Safety Ratings EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1 Safety Classification Cat. 1 device per EN 954-1 dual channel


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC609475-1, IEC/EN60947-5-3, AS4024 889D-F4ACDM- 440N-Z2NRS1A 440N-Z2NRS1C 440NZ2NRS1B 440N-Z21W1PH 440N-Z21W1PA 440N-Z21W1PB 440R-W23219 440R-N23132 440r-h23176 MSR127TP

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Text: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    PDF NFC63-110, VDE0660, BS5424, JEM1038 IEC60947-4 VDE 0660 iec 158-1 NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660

    mcb tripping curves

    Abstract: S2H11 S2-H11 ABB SHUNT TRIP IEC60947-2 IEC60898 mcb B CURVE TRIPPING VOLTAGE S2-H02 ABB MCB s260 ABB MCB
    Text: Line Protection Devices MCB- S270 & S260 series Conforms to IEC60898, IS8828-10kA and IEC60947-2 ABB- the pioneer in MCB technology brings to you the S270 range based on system pro M, a modular system developed by ABB. The S270 range of MCBs are designed and constructed to


    Original
    PDF IEC60898, IS8828-10kA IEC60947-2 IS8828 IEC60898 IEC60947/2 90x17 12-64AC 12-110DC 125-415AC mcb tripping curves S2H11 S2-H11 ABB SHUNT TRIP IEC60947-2 mcb B CURVE TRIPPING VOLTAGE S2-H02 ABB MCB s260 ABB MCB

    GB14048. 3

    Abstract: GB14048 IEC60947-3 gb14048.3 50mm2 disconnector IEC60947
    Text: XMG0 series insulated disconnector „ Applicable for industrial, commercial and civilian electric line as main disconnector. „ Conform to standards IEC60947.3,GB14048.3 „ Rated voltage 230/400V.a.c „ Frequency 50/60Hz „ Application type: AC-22B „ Double functioned terminal, high connection capability


    Original
    PDF IEC60947 GB14048 230/400V 50/60Hz AC-22B 50mm2 GB14048. 3 IEC60947-3 gb14048.3 50mm2 disconnector

    msr127tp

    Abstract: 440R-N23126 msr127t 440R-N23132 MSR127RP 440R-N23135 MSR127R msr127 440R-N23129 minotaur msr127tp
    Text: Safety Relays Monitoring Safety Relays Minotaur MSR127RP/TP Specifications Description Standards EN954-1, ISO13849-1, IEC/ EN60204-1, IEC60947-4-1, IEC60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 4 per EN 954-1 ISO 13849-1 Approvals CE marked for all applicable


    Original
    PDF MSR127RP/TP 50/60Hz EN954-1, ISO13849-1, EN60204-1, IEC60947-4-1, IEC60947-5-1, AS4024 MSR127RTP from34 msr127tp 440R-N23126 msr127t 440R-N23132 MSR127RP 440R-N23135 MSR127R msr127 440R-N23129 minotaur msr127tp

    440N-S32014

    Abstract: 889D-F8Ac-5 440N-S32015 440N-S32024 sipha 440n 440N-S32047 440N-S32016 889D-F8AC-10 sensor s42
    Text: Interlock Switches Non contact Switches Sipha Sensors Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, IEC/EN60947-5-3, ANSI B11.19, AS4024.1 Category Rating dependent on control unit and application. Approvals


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, IEC/EN60947-5-3, AS4024 440N-S32014 889D-F8Ac-5 440N-S32015 440N-S32024 sipha 440n 440N-S32047 440N-S32016 889D-F8AC-10 sensor s42

    GTK-85

    Abstract: GMC-18 GMD-22 GMC-22 GTK4 GTH-85 GMD-85 GTH-22 GMC-32 GMC-9-AC120V
    Text: Contactors 9 to 85A 9A Frame size 12A 18A 22A 3-pole Contactors For further technical information see pages 8-9. Types includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) AC coil DC coil Ratings / IEC60947-4 AC1 AC3 200/240V 380/440V 500/550V 690V Ratings / UL508


    Original
    PDF IEC60947-4 200/240V 380/440V 500/550V UL508 GMC-12 GMD-12 GMC-18 GMD-18 GMC-22 GTK-85 GMC-18 GMD-22 GMC-22 GTK4 GTH-85 GMD-85 GTH-22 GMC-32 GMC-9-AC120V

    Untitled

    Abstract: No abstract text available
    Text: Mini contactors Mini contactors providing various connections and Accessories Screw clamps Fast-on For conventional screw connections For fast-on connections Ratings AC3 ratings IEC60947-4 Frame size 6A 9A 12A 380 ~ 500 ~ 240V 440V 550V 1.5kW 2.2kW 3kW 3kW


    Original
    PDF IEC60947-4) CGMS-12D CGMUS-12A CGMUS-12D CGMS-12A

    Thermal Overload Relay GTH-22

    Abstract: GMC-16m GTH-22 SMC-25P2 GMC-400 GMC-220 GMC-300 smc-30p2 GMC-16MP GMC-600
    Text: Contactors 9 to 85A 9A Frame size 12A 18A 22A 3-pole Contactors For further technical information see pages 8-9. Types includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) AC coil DC coil Ratings / IEC60947-4 AC1 AC3 200/240V 380/440V 500/550V 690V Ratings / UL508


    Original
    PDF IEC60947-4 200/240V 380/440V 500/550V UL508 GMC-12 GMD-12 GMC-18 GMD-18 GMC-22 Thermal Overload Relay GTH-22 GMC-16m GTH-22 SMC-25P2 GMC-400 GMC-220 GMC-300 smc-30p2 GMC-16MP GMC-600

    IEC60947-5-1

    Abstract: interlock security switch 440n 440n-n15015 EN954-1 sentinel IEC60947-5 circuit diagram of door interlock system EN-954 AS4024
    Text: Interlock Switches Non contact Switches Sentinel 1 Specifications Standards EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, ANSI B11.19, AS4024.1 Category Cat. 3 per EN954-1 Approvals CE marked for all applicable directives Power Supply


    Original
    PDF EN954-1, ISO13849-1, IEC/EN60204-1, NFPA79, EN1088, ISO14119, IEC60947-5-1, AS4024 EN954-1 250mA IEC60947-5-1 interlock security switch 440n 440n-n15015 EN954-1 sentinel IEC60947-5 circuit diagram of door interlock system EN-954

    circuit diagram of door status switch

    Abstract: sliding Door plc ALC-103 SEIWA led lamp IEC60947-5-1 main panel circuit diagrams of sliding door RBC-103PG13 60269-2 EN1088 EN60947-5-1
    Text: Door Interlock Switches HS1B Series HS1B Series Full Size Interlock Switch HS1B features: GS-ET-15 BG standard in Germany X Series E-Stops EN1088 EN60947-5-1 IEC60947-5-1 Overview • Rugged aluminum die-cast housing • Direct Opening Action: If the door is forced open, the contacts are disconnected even if


    Original
    PDF GS-ET-15 EN1088 EN60947-5-1 IEC60947-5-1 HS1B-114R-R HS1B-114R-G SCS-10* 1/2-14NPT circuit diagram of door status switch sliding Door plc ALC-103 SEIWA led lamp IEC60947-5-1 main panel circuit diagrams of sliding door RBC-103PG13 60269-2 EN1088 EN60947-5-1

    D4V-8104Z

    Abstract: D4V-8166Z GB14048 D4V-8107 EN 60947-5-1 OMRON OMRON wl 8122Z gb14048.5
    Text: Small Limit Switch D4V Compact Vertical Models Sized for Asian Standards • Compact new design approximately 1/3 the size of OMRON vertical Limit Switches. • Structure enables the terminal section to be fully opened for easy wiring. • RoHS complaint.


    Original
    PDF D4V-81@ D4V-8104Z D4V-8107Z D4V-8108Z D4V-8111Z D4V-8112Z D4V-8122Z C139-E1-01 D4V-8166Z GB14048 D4V-8107 EN 60947-5-1 OMRON OMRON wl 8122Z gb14048.5

    Omron

    Abstract: gf24 A3CT-7011 A3CJ-90A1-24E gb14048.5 A16-12DW A3CT-90A1-24E A3CT-90B1-24E GB140
    Text: A3C Pushbutton Switch Lighted/Non-Lighted (Cylindrical 12-dia.) CSM_A3C_DS_E_2_1 Pushbutton Switch Series with Cylindrical 20-mm x 12-dia. Body • High-intensity uniform surface lighting. • Round body enables easy hole making. • Miniature size with excellent feeling of operation.


    Original
    PDF 12-dia. 20-mm A030-E1-05 Omron gf24 A3CT-7011 A3CJ-90A1-24E gb14048.5 A16-12DW A3CT-90A1-24E A3CT-90B1-24E GB140

    gb14048.5

    Abstract: GB14048. 3 GB14048 D4BS-85FS D4BS-2AFS D4BS55FS A600 E76675 EN60947-5-1 D4BS-35FS
    Text: Safety Interlock Switches D4BS D4BS Safety-Door Switch • The special operation key activates a direct opening mechanism to open the contacts and shut off control circuits when protective doors are opened on machine tools or other equipment • Conforms to EN TÜV standards corresponding to the CE marking.


    Original
    PDF EN60947-5-1) D4BS-35FS D4BS-45FS D4BS-55FS D4BS-65FS 14NPT D4BS-75FS D4BS-25FS D4BS-15FS gb14048.5 GB14048. 3 GB14048 D4BS-85FS D4BS-2AFS D4BS55FS A600 E76675 EN60947-5-1 D4BS-35FS

    IEC60947-1

    Abstract: No abstract text available
    Text: Óñòðîéñòâî òîðìîæåíèÿ - Êîìïàêòíîå MBG Ýëåêòðîííîå óñòðîéñòâî òîðìîæåíèÿ Íå òðåáóåò äîïîëíèòåëüíûõ àêñåññóàðîâ Âñòðîåííûé êîíòàêòîð òîðìîæåíèÿ


    Original
    PDF MBG20 MBG10 MBG35 101mm IEC60947-1

    SR6A4024

    Abstract: SR6B4024 SR6A4110 SR6A4012 SR6B4018 SR6B4085 SR6B4060 V23050A1024A542 1393260-7 SR6C4024 SR6B4048
    Text: General Purpose Relays Force Guided Relays Schrack Force Guided Relay SR6 A/B/C/V n 6 pole relay with force guided contacts according to EN 50205 insulation between all contacts n Reinforced Typical applications Emergency shut-off, press control, machine control, elevator and escalator


    Original
    PDF F0206-EA E214024, 968/EL 800mW 110VDC 1200mW 800mW SR6A4024 SR6B4024 SR6A4110 SR6A4012 SR6B4018 SR6B4085 SR6B4060 V23050A1024A542 1393260-7 SR6C4024 SR6B4048

    sr2m v23047-a1024-a511

    Abstract: No abstract text available
    Text: General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M n 2 pole relay with force guided contacts according to EN 50205 insulation between poles n Version for use in sockets n Reinforced Typical applications Emergency shut-off, press control, machine control, elevator and escalator


    Original
    PDF F0188-D 12VDC 18VDC 21VDC 24VDC 36VDC 40VDC 48VDC 60VDC 110VDC sr2m v23047-a1024-a511

    shroud for mushroom head push button

    Abstract: 40-dia A165-AM-2 zener diode reference guide A22T SMD MARKING CODE OMRON a3t A3PJ-7010-1 seoul smd led 5050 A3PJ-5126 reflective sensors
    Text: Pushbutton Switches OMRON Corporation Industrial Automation Company Sensing Devices Division H.Q. Industrial Sensors Division Shiokoji Horikawa, Shimogyo-ku, Kyoto, 600-8530 Japan Tel: 81 75-344-7022/Fax: (81)75-344-7107 In the interest of product improvement, specifications are


    Original
    PDF 75-344-7022/Fax: X032-E1-08 0206-1M 81-3-3779-9001/Fax: omron247 shroud for mushroom head push button 40-dia A165-AM-2 zener diode reference guide A22T SMD MARKING CODE OMRON a3t A3PJ-7010-1 seoul smd led 5050 A3PJ-5126 reflective sensors

    2158001

    Abstract: CQC0617015579 v23047-a1024-a511 E214025 IEC60947-5-1 EN 50205 EN50205
    Text: General Purpose Relays Force Guided Relays SCHRACK Force Guided Relay SR2M n 2 pole relay with force guided contacts according to EN 50205 insulation between poles n Reinforced Typical applications Emergency shut-off, press control, machine control, elevator and escalator


    Original
    PDF F0188-D 2158001 CQC0617015579 v23047-a1024-a511 E214025 IEC60947-5-1 EN 50205 EN50205

    GS100101

    Abstract: GS100102 GS100201 GS100202 GS100203 GS100301 GS100302 GS100303 IEC60947-5-2 GS100402
    Text: G S GEARTOOTH SPEED SENSOR ASSEMBLIES S E R I E S Industrial-grade, Hall effect geartooth speed sensor with adjustable stainless steel housing. GS1001–1004 Industrial Grade • ■ ■ ■ ■ ■ ■ ■ ■ Sense Motion of Ferrous Geartooth Targets Near-Zero Speed Sensing Capability


    Original
    PDF GS1001 -24VDC IEC60947-5-2 GS100303 GS100401 GS100402 GS100403 GS100101 GS100102 GS100201 GS100202 GS100203 GS100301 GS100302 GS100303 IEC60947-5-2 GS100402

    transistor ac51

    Abstract: NFEN55011 EN61000-4-2 SCM030200
    Text: celduc r e l a i S/CON/SCM030200/B/07/06/04 s PRELIMINARY !! Page 1/5 GB MOSFET BASED DC SOLID STATE RELAY SCM030200 X Latest MOSFET technology generation. X Ultra low on-state resistance. X New innovative isolated driver ensuring fast power transistor turn on and off therefore low power transient.


    Original
    PDF S/CON/SCM030200/B/07/06/04 SCM030200 InWF070000 WF151200 WF121000 55K/W WF050000 1K470000 transistor ac51 NFEN55011 EN61000-4-2 SCM030200

    SCREW

    Abstract: CA625/10
    Text: Feed-Through CTS2.5U-N Altech “U” Series Universal Rail Mounting Standard Screw Clamp Feed through terminals are the most versatile terminals for wire-to-wire connection in control, automation, instrumentation and power distribution applications. A special design fea- Terminal Width


    Original
    PDF PTB35/50 PTB35/50SH PTB70/95 PTB70/95SH CA102 CA202 CA703/9 CA704/9 SCREW CA625/10

    Untitled

    Abstract: No abstract text available
    Text: You can find us everywhere. Energie-Messtechnik Energie-Management Netzqualitäts-Lösungen Software & Zubehör Power Quality Monitoring Power Management Power Quality Solutions Software & Accessories There must be a reason. Current transformers ▼ Current transformers


    Original
    PDF EN/IEC60900 D-35633

    star delta wiring diagram motor start y

    Abstract: omron ct E54-CT1 circuit for heater power controller using triac star delta triac diagram induction heater G3PB-225B-VD star delta wiring diagram water heater usb diagram for heater power controller using triac iec60947-2
    Text: Multi-channel Power Controller G3ZA Optimum Cycle Control for High-precision Control with Low Noise • Smaller than a Normal Power Controller. • Enables low-noise power control in combination with zero-cross SSRs. See note. • One Controller can control up to 8 SSRs.


    Original
    PDF RS-485 for150-A star delta wiring diagram motor start y omron ct E54-CT1 circuit for heater power controller using triac star delta triac diagram induction heater G3PB-225B-VD star delta wiring diagram water heater usb diagram for heater power controller using triac iec60947-2