Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    650 GAS ARRESTOR Search Results

    650 GAS ARRESTOR Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    SGAS701 Renesas Electronics Corporation Trace Hydrogen Gas Sensor Visit Renesas Electronics Corporation
    Household-Gas-Alarm Renesas Electronics Corporation Household Gas Alarm Reference Design Visit Renesas Electronics Corporation
    SGAS711 Renesas Electronics Corporation Flammable Gas Sensor - Methane, Propane, Hydrogen, LPG Visit Renesas Electronics Corporation
    High-End-Gas-Cooker Renesas Electronics Corporation High-End Gas Cooker Reference Design Visit Renesas Electronics Corporation
    SMOD711KITV1 Renesas Electronics Corporation Flammable Gas Leak Sensor Evaluation Kit Visit Renesas Electronics Corporation

    650 GAS ARRESTOR Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: 2015 THIS PAGE INTENTIONALLY LEFT BLANK. Gas Discharge Tubes Table of Contents General Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF

    Ka 202 A

    Abstract: connector ptr 650 gas arrestor TNC connector NexTek GAS ARRESTOR lightning arrestor 101D 106E 107D
    Text: Product Specification PTRTNxTNFxxS Gas Discharge Tube Lightning Arrestor TNC Connectors and a Replaceable Protective Element Features:  DC pass  Multiple Strike Capability  40 kA Surge Protection  Bi-directional Protection  Rugged and Water Resistant


    Original
    PDF 2X50s 8X20s Ka 202 A connector ptr 650 gas arrestor TNC connector NexTek GAS ARRESTOR lightning arrestor 101D 106E 107D

    650 gas arrestor

    Abstract: gas tube Ka 202 A lightning arrestor 60-1600 GAS ARRESTOR 350 gas arrestor connector ptr gas discharge hrs connector
    Text: Product Specification PTRBNxBNFxxS Gas Discharge Tube Lightning Arrestor BNC Connectors and a Replaceable Protective Element Features:  Frequency to 2.5 GHz  Excellent RF Performance  Multiple Strike Capability  40 kA Surge Protection  Bi-directional Protection


    Original
    PDF 2X50s 8X20s 8x20s) 2x50s/ 8x20s. 650 gas arrestor gas tube Ka 202 A lightning arrestor 60-1600 GAS ARRESTOR 350 gas arrestor connector ptr gas discharge hrs connector

    650 gas arrestor

    Abstract: Ka 202 A lightning arrestor 90 09 GAS ARRESTOR lightning arrestor 101D 106E 107D 204D IEC529
    Text: Product Specification PTRONxONFxxS Gas Discharge Tube Lightning Arrestor N Connectors and a Replaceable Protective Element Features:  Frequency to 3.2 GHz Excellent RF Performance  Multiple Strike Capability  50 kA Surge Protection  Bi-directional Protection


    Original
    PDF 5V/10A 2X50s 8X20s 650 gas arrestor Ka 202 A lightning arrestor 90 09 GAS ARRESTOR lightning arrestor 101D 106E 107D 204D IEC529

    2rm600

    Abstract: 2r230 2R350 2R90 2N600 2rm60 2rm150 WPGT-2RM800 3r230 3SM35
    Text: THIS PAGE INTENTIONALLY LEFT BLANK. Gas Discharge Tubes Table of Contents General Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF

    2R350

    Abstract: 2rm150 2r230 2rm600 WPGT-2SM90 3r230 2N90 470-1000V 3r75 WPGT-2R3000
    Text: Gas Discharge Tubes World Products, LLC 19654 Eighth Street East, Sonoma, CA 95476 | Phone 707 996-5201 | Fax (707) 996-3380 | www.worldproducts.com Rev. 12.2 (04.22.10) Gas Discharge Tubes | 249 Gas Discharge Tubes THIS PAGE INTENTIONALLY LEFT BLANK. World Products, LLC 19654 Eighth Street East, Sonoma, CA 95476 | Phone (707) 996-5201 | Fax (707) 996-3380 | www.worldproducts.com


    Original
    PDF

    2rm600

    Abstract: 2R350 WPGT-2SM90 2R600 2rm150 WPGT-2S2500 2R230 2RM350 WPGT-2S2000 3r230
    Text: THIS PAGE INTENTIONALLY LEFT BLANK. Gas Discharge Tubes Table of Contents General Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Rating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF

    diode MARKING CODE CG

    Abstract: CG2-230L CG75 gas arrestors GDT 230 surge arrester 72.5 kv 60286-1 CG 472 GDTs CG110
    Text: Gas Plasma Arrester GDT Products Medium to High Surge Arrestors > CG/CG2 Series CG/CG2 Series Description Littelfuse highly reliable CG/CG2 Series GDTs provide a high degree of surge protection in a small size ideal for board level circuit protection.


    Original
    PDF RS-296-E diode MARKING CODE CG CG2-230L CG75 gas arrestors GDT 230 surge arrester 72.5 kv 60286-1 CG 472 GDTs CG110

    Untitled

    Abstract: No abstract text available
    Text: Gas Discharge Tube GDT Products SL1021A/B, SL1024A/B and PMT8 Series SL1021A/B, SL1024A/B and PMT8 Series Description GDT circuit protection devices dissipate electrical surge energy safely within a contained plasma gas. Commonly used to help protect sensitive telecom and


    Original
    PDF SL1021A/B, SL1024A/B SL1021A/B 50pcs/tray 500pcs/reel*

    HD64F3067

    Abstract: GR-1361-CORE SL1021 GR1361 SL1021B500 gas discharge SL1021B145 sl1021b
    Text: Gas Discharge Tube GDT Products SL1021A/B, SL1024A/B and PMT8 Series SL1021A/B, SL1024A/B and PMT8 Series Description GDT circuit protection devices dissipate electrical surge energy safely within a contained plasma gas. Commonly used to help protect sensitive telecom and


    Original
    PDF SL1021A/B, SL1024A/B SL1021A/B 50pcs/tray 500pcs/reel* HD64F3067 GR-1361-CORE SL1021 GR1361 SL1021B500 gas discharge SL1021B145 sl1021b

    SL1021B145

    Abstract: sl1021b
    Text: Gas Discharge Tube GDT Products SL1021A/B, SL1024A/B and PMT8 Series SL1021A/B, SL1024A/B and PMT8 Series Description GDT circuit protection devices dissipate electrical surge energy safely within a contained plasma gas. Commonly used to help protect sensitive telecom and


    Original
    PDF SL1021A/B, SL1024A/B E128662 8/20s SL1021B145 sl1021b

    310 series

    Abstract: tl 464 PE-80
    Text: Gas Plasma Arrester GDT Products PMT3(310) Series PMT3(310) Series Description Littelfuse three electrode PMT3(310) series GDTs are designed primarily to protect telecommunications equipment requiring simultaneous crowbar action of two signal lines. GDTs function as switches;


    Original
    PDF E128662 310 series tl 464 PE-80

    Untitled

    Abstract: No abstract text available
    Text: Gas Discharge Tube GDT Products PMT3(310) Series PMT3(310) Series Description Littelfuse three electrode PMT3(310) series GDTs are designed primarily to protect telecommunications equipment requiring simultaneous crowbar action of two signal lines. GDTs function as switches;


    Original
    PDF E128662 vario579]

    circuit diagram of surge protector for AC mains

    Abstract: ptc overvoltage protections ptc overvoltage protections application note THDT58D THBT200D pabx ring generator sinus generator carbon variable resistor crowbar ptc relay
    Text: APPLICATION NOTE  SLIC PROTECTION A. BREMOND I INTRODUCTION The goal of the telecommunication network fig.1 is to permit the data exchange (speech or digital) between two (or more) subscribers. The network is made up of different parts which are subject to various disturbances.


    Original
    PDF

    Ericsson bts installation guide

    Abstract: ericsson BTS and antenna installation ericsson BTS GSM 1800 Nokia BTS ericsson bts Technical specification BTS Base Terminal alcatel indoor BTS of ericsson siemens 230 gas discharge tube TNC PROTECTIVE CAP BTS 6000 ericsson
    Text: Lightning Protectors Edition 2008/2009 Excellence in Connectivity Solutions Introduction content Introduction page 6 Definitions and terms page 27 Quick selection page 37 Products page 53 Accessories page 129 Application notes page 143 General information


    Original
    PDF

    varistor 593 ph 275v

    Abstract: varistor 275 593 ph S20 K275 varistor ABB inverter motor fault code
    Text: CATALOGUE 4.4 www.weidmueller.com Saudi Arabia Serbia Singapore Slovakia Slovenia South Africa Spain Sweden Switzerland Taiwan Thailand Tunisia Turkey Ukraine United Arab Emirates United States Uruguay Uzbekistan Venezuela Vietnam Weidmüller is a leading international provider of solutions


    Original
    PDF 1271290000/01/2011/SMMD varistor 593 ph 275v varistor 275 593 ph S20 K275 varistor ABB inverter motor fault code

    Ericsson bts installation guide

    Abstract: ericsson BTS and antenna installation Ericsson tma for gsm 900 Ericsson tma ericsson bts Technical specification ericsson BTS GSM 1800 TMA ericsson 1800 BTS 6000 ericsson BTS Base Terminal alcatel SCHEMATIC DIAGRAM OF 2.4 GHZ WIFI RF POWER
    Text: General, detailed selection flow chart for HUBER+SUHNER lightning protectors HUBER+SUHNER – Excellence in Connectivity Solutions HUBER+SUHNER is a leading global supplier of components and systems for electrical and optical connectivity in communications, industrial and transportation markets.


    Original
    PDF prot061 BNC-0-0-15 Ericsson bts installation guide ericsson BTS and antenna installation Ericsson tma for gsm 900 Ericsson tma ericsson bts Technical specification ericsson BTS GSM 1800 TMA ericsson 1800 BTS 6000 ericsson BTS Base Terminal alcatel SCHEMATIC DIAGRAM OF 2.4 GHZ WIFI RF POWER

    supressor diode S20 K30

    Abstract: TT 2206 horizontal d Metal-Oxide Varistor S14 VARISTOR s14 K30 VDE 0542 tt 2206 horizontal 8523740000 K30 varistor S20 K25 varistor varistor k25
    Text: Overvoltage Protection 234 Overvoltage Protection Overvoltage Protection The electronic equipping of electrical installations is becoming increasingly complex. PLC controls and PC applications are replacing hard-wired relay technology. Interferences from overvoltage or switching


    Original
    PDF mm/89 supressor diode S20 K30 TT 2206 horizontal d Metal-Oxide Varistor S14 VARISTOR s14 K30 VDE 0542 tt 2206 horizontal 8523740000 K30 varistor S20 K25 varistor varistor k25

    YP-141N

    Abstract: YA-501 ys-301 YP-141 N YS-701 zener diodes color coded YP-251 YP-501M yp501 surge absorber
    Text: BL SURGE ABSORBER BL mini Surge Absorber BLSA , invented and produced by Japan BL Kogyo INC. , is a series of high-tech electronic components and is fully protected by international patent law . Its patent register number in Japan is HEI 7-16632 ; in USA: 08/378,969 ; in Korean: 2021/1995 ; in China: 94202711.6 . BL Surge


    Original
    PDF 25MAX) YP-141N YA-501 ys-301 YP-141 N YS-701 zener diodes color coded YP-251 YP-501M yp501 surge absorber

    ups repair manual

    Abstract: high frequency ups main card drawing UPS chloride circuit ups working UPS RELAY CIRCUIT ups SERVICE MANUAL ASD35S2U stand by UPS SAVE THE BATTRY UPS repair Chloride
    Text: M0005811B Uninterruptible Power Supply SANUPS ASD ASD35S2U Instruction Manual Introduction Thank you for your purchasing of this equipment ASD35S2U . SAVE THE INSTRUCTIONS This Manual contains important information for Model ASD35S2U that should be followed


    Original
    PDF M0005811B ASD35S2U ASD35S2U) ASD35S2U ups repair manual high frequency ups main card drawing UPS chloride circuit ups working UPS RELAY CIRCUIT ups SERVICE MANUAL stand by UPS SAVE THE BATTRY UPS repair Chloride

    VOGT 503

    Abstract: 503 16 504 00 vogt VOGT u3 503 10 T60403-L4025-X021 vogt 503 20 vogt transformer VOGT EF20 vogt smd 503 20 T60407 vogt* 503
    Text: Application Hint DS1, 2001-09-12 2B1Q Second Generation Modular ISDN NT Q-SMINT O, I, IX PEF 80912, 82912, 81912, 80913, 82913, 81913 Version 1.3 1 External Components for Q-SMINT Applications 1.1 Sourcing Lists for Interface Transformers Table 1 and Table 2 contain information pertaining to interface transformers suitable for


    Original
    PDF

    100a lead acid charger

    Abstract: ups repair manual UPS chloride circuit mccb ASD140S2U chage leak battery ASD35S2N flower in the rain inverter repair inverter stand alone
    Text: M0005809C Uninterruptible Power Supply SANUPS ASD ASD 70S2U, 35S2NU ASD100S2U, 70S2NU ASD140S2U,100S2NU Instruction Manual Introduction Thank you for your purchasing of this equipment UPS . SAVE THE INSTRUCTIONS This Manual contains important information for Model ASD“ ”U that should be followed


    Original
    PDF M0005809C 70S2U, 35S2NU ASD100S2U, 70S2NU ASD140S2U 100S2NU 100a lead acid charger ups repair manual UPS chloride circuit mccb chage leak battery ASD35S2N flower in the rain inverter repair inverter stand alone

    unigy

    Abstract: unigy 11 battery WP-93379 Battery charger 48 volt forklift forklift battery charger circuit 652-568 unigy 93379 6a859 relay comcode 105 736 490 1A-85-57
    Text: Unigy II Batteries WP-93379 Product Manual Select Code 157-622-030 Comcode 107728016 Issue 9 January 2008 Product Manual Select Code 157-622-030 Comcode 107728016 Issue 9 January 2008 Unigy® II Batteries WP-93379 Notice: The information, specifications, and procedures in this manual are


    Original
    PDF WP-93379 unigy unigy 11 battery WP-93379 Battery charger 48 volt forklift forklift battery charger circuit 652-568 unigy 93379 6a859 relay comcode 105 736 490 1A-85-57

    14DK471

    Abstract: 07DK391 20dk431 SiC varistor 14DK431 sec 472 varistor varistor ve 17 varistor 471 14 10DK271 varistor 7 k 471
    Text: TYPE VSA VARISTORS TRANSIENT / SURGE ABSORBER APPLICATIONS FEATURES Transistor, diode, IC, thyristor and triac semiconductor protection, lurge protection in consumer electronics, lurge protection in industrial electronics. Jurge protection in communication, measuring and


    OCR Scan
    PDF Vcat20Â 14DK471 07DK391 20dk431 SiC varistor 14DK431 sec 472 varistor varistor ve 17 varistor 471 14 10DK271 varistor 7 k 471