Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    5 ZONE ALARM SYSTEM Search Results

    5 ZONE ALARM SYSTEM Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    CS-VHDCIMX200-003 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-003 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 3m Datasheet
    CS-VHDCIMX200-000.5 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-000.5 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male .5m Datasheet
    CS-VHDCIMX200-005 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-005 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 5m Datasheet
    CS-VHDCIMX200-006 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-006 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 6m Datasheet
    CS-VHDCIMX200-001 Amphenol Cables on Demand Amphenol CS-VHDCIMX200-001 VHDCI SCSI (SCSI-5) LVD/SE Cable - .8mm 68-pin VHDCI SCSI Male to Male 1m Datasheet

    5 ZONE ALARM SYSTEM Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    GF505

    Abstract: No abstract text available
    Text: Flex Series GF505 and GF510 5 and 10 Zone Conventional Fire Alarm Control Panels Description The Flex 505 is a five zone fire alarm control panel FACP and the Flex 510 is a ten zone FACP. These combination control and digital communicator panels provide reliable


    Original
    PDF GF505 GF510 microprocessoANN-80W ANN-SB80KIT-R ANN-80, ANN-SB80KIT-W N-ANN-80

    Untitled

    Abstract: No abstract text available
    Text: µltraWave TM Datasheet µltraWave™ Microwave intrusion detection system Features & Benefits • Zone lengths from 5 to 200 m 16 to 656 ft. ; stackable for increased detection zone height • High Probability of detection (Pd) • Low Nuisance Alarm Rate (NAR)


    Original
    PDF 10/100BASE-TX E4FG0101 E4EM0101 E4EM0201

    EOL-P1

    Abstract: No abstract text available
    Text: GE Security EST Fire & Life Safety Control Panels Overview Standard Features The FireShield fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these


    Original
    PDF 12V4A 12V6A5 12V10A 12V17A EOL-P1

    Untitled

    Abstract: No abstract text available
    Text: OMA-VM500-5 OMEGAPHONE Eight Zone Temperature Alarm Dialer 345 $ Basic Unit MADE IN USA ߜ Monitors Eight Channels of Temperature Input and Power ߜ Program up to Four 20 Digit Phone Numbers ߜ Works with Telephone Pagers ߜWall Mount Enclosure ߜ Optional 4-Line Display


    Original
    PDF OMA-VM500-5 OMA-VM500-5 30-hour OMA-VM500-5-B20 20-hour OMA-VM500-5-B20

    Untitled

    Abstract: No abstract text available
    Text: Features Flex 410 • 10 zones Class B Style B , or 5 Class A (Style D) zones. Expandable to 20 zones Class B or 10 zones Class A. Fire Alarm Control Panel with Digital Communicator • Supervised zone expanders and I/O modules can be mounted remotely from the main control


    Original
    PDF g2410ph1 g2410wir2 CS-2410

    DA Abacus 8P

    Abstract: 335-536 333-192 abacus panel BS4737 Detector intruder
    Text: Data Pack C Issued March 2001 232-4336 Abacus intruder alarm systems Data Sheet An intruder alarm system is a secondary form of protecting a property. There is little or no point in fitting a system if you have not first considered physical protection. Locks, bolts


    Original
    PDF

    abacus panel

    Abstract: ultrasonic proximity detector DA Abacus 8P COMET L PIR SIMPLE DOOR ALARM SYSTEM free C16651 ultrasonic proximity detector circuit 5 zone alarm system vibration detector Wired Smoke Detector alarm
    Text: Issued March 1994 C16651 Abacus intruder alarmsystems RS stock numbers 627-914, 627-920, 740-427, 740-433, 740-477 An intruder alarm system is a secondary form of protecting a property. There is little or no point in fitting a system if you have not first considered physical


    Original
    PDF C16651 abacus panel ultrasonic proximity detector DA Abacus 8P COMET L PIR SIMPLE DOOR ALARM SYSTEM free C16651 ultrasonic proximity detector circuit 5 zone alarm system vibration detector Wired Smoke Detector alarm

    block diagram for fire alarm system

    Abstract: automatic heat detector report AIR FLOW DETECTOR FULL REPORT BS5445 block fire alarm system block diagram AIR FLOW DETECTOR FULL REPORT using led fire alarm system block diagram fire alarm using thermistor BS6007 rate of rise heat detectors
    Text: Issued March 1994 C17171 Multizonefirealarmsystems There are two main reasons for installing fire alarm systems, the protection of life and the protection of property. Fire can kill or maim in many ways eg. by asphyxiation, irradiation, poisoning or burning and legislation has


    Original
    PDF C17171 block diagram for fire alarm system automatic heat detector report AIR FLOW DETECTOR FULL REPORT BS5445 block fire alarm system block diagram AIR FLOW DETECTOR FULL REPORT using led fire alarm system block diagram fire alarm using thermistor BS6007 rate of rise heat detectors

    Untitled

    Abstract: No abstract text available
    Text: Category 3 Safety laser scanner Two zone programmable area control APPLICATIONS • Horizontal detection like a sensitive mat of people or objects • Anti-collision system for AGVs BIA Berufsgenossenschaftliches Institut für Arbeitssicherheit (Pending)


    Original
    PDF RS232

    infrared based security alarm

    Abstract: 5 zone alarm system V923 V-0020 report for infrared based security alarm infrared based security system passive infrared detector
    Text: Technical Data Security Systems Passive Infrared Detector IR/N Description VSM 7151.95 The passive infrared detector has been manufactured using the latest SMD production technology and has achieved a significant increase in immunity to highfrequency interference due to a simultaneous reduction in components and cable


    Original
    PDF D-69006 D-69123 V0001 V0002 V0003 V0020 D0201 infrared based security alarm 5 zone alarm system V923 V-0020 report for infrared based security alarm infrared based security system passive infrared detector

    context plus fire alarm control panel

    Abstract: keypad 4*4 "fire Smoke Sensor" FIRE SENSOR LS2 buzzer "Smoke Sensor" VN340SP
    Text: UM0272 User manual Central Unit for Alarm System CUAS Evaluation Board Introduction The Central Unit for Alarm System (CUAS) Evaluation Board provides a complete reference system addressing the low- to middle-end security sectors. The tool is ready, from hardware


    Original
    PDF UM0272 context plus fire alarm control panel keypad 4*4 "fire Smoke Sensor" FIRE SENSOR LS2 buzzer "Smoke Sensor" VN340SP

    4 digit 7 segment display pic16f877

    Abstract: 2 digit 7 segment display pic16f877 PIC16F877 Free Projects keypad 4 digit 7 segment display basic pic16f877 salvo rtos PIC16F877 interrupt PICC compiler HDSP-7301 ,4 digit 7 segment display pic16f877 7 segment display pic16f877 pic16f877 led pot
    Text: M AN777 Multi-Tasking on the PIC16F877 with the Salvo RTOS Authors: Chris Valenti Microchip Technology Inc. Andrew E. Kalman, Ph.D. Pumpkin, Inc. INTRODUCTION This application note covers a Real-Time Operating System RTOS running on a PIC16F877. The application is written in C using the HI-TECH C compiler.


    Original
    PDF AN777 PIC16F877 PIC16F877. D-81739 D-82152 DS00777B-page 4 digit 7 segment display pic16f877 2 digit 7 segment display pic16f877 PIC16F877 Free Projects keypad 4 digit 7 segment display basic pic16f877 salvo rtos PIC16F877 interrupt PICC compiler HDSP-7301 ,4 digit 7 segment display pic16f877 7 segment display pic16f877 pic16f877 led pot

    2 digit 7 segment display pic16f877

    Abstract: 7 segment display pic16f877 4 digit 7 segment display pic16f877 HDSP-7301 pic16f877 pragma nec 2401 PIC16F877 Free Projects keypad salvo rtos USART keypad PIC applications
    Text: AN777 Multi-Tasking on the PIC16F877 with the Salvo RTOS Authors: Chris Valenti Microchip Technology Inc. Andrew E. Kalman, Ph.D. Pumpkin, Inc. INTRODUCTION This application note covers a Real-Time Operating System RTOS running on a PIC16F877. The application is written in C using the HI-TECH C compiler.


    Original
    PDF AN777 PIC16F877 PIC16F877. D-81739 D-82152 DS00777A-page 2 digit 7 segment display pic16f877 7 segment display pic16f877 4 digit 7 segment display pic16f877 HDSP-7301 pragma nec 2401 PIC16F877 Free Projects keypad salvo rtos USART keypad PIC applications

    Untitled

    Abstract: No abstract text available
    Text: Category 3 Safety laser scanner Two zone programmable area control APPLICATIONS • Horizontal detection like a sensitive mat of people or objects • Anti-collision system for AGVs BIA Berufsgenossenschaftliches Institut für Arbeitssicherheit NRTL/C (Pending)


    Original
    PDF

    PR5202

    Abstract: 5 zone alarm system
    Text: 25/10/01 09:35 Page 1 TM USER.qxd CP8L LCD USER M A N UA L TM USER.qxd 25/10/01 09:35 Page 2 Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Full Setting the System . . . . . . . . . . . . . . . . . . . . 1 Part Setting the System using Part 1 . . . . . . . . 2


    Original
    PDF PR5202 5 zone alarm system

    Untitled

    Abstract: No abstract text available
    Text: FiberPatrol-ZR TM Datasheet FiberPatrol-ZR Zone-reporting intrusion detection system Features & Benefits • Detect perimeter intrusions over a distance of up to 2.5 km 1.6 mi. • Up to 28 software-configurable detection zones • 100% operational after a cable cut in


    Original
    PDF 00FG0220 DAS-FZR-IN-R1-E-07/14

    PIR based security system

    Abstract: infrared based security alarm "PIR wiring diagram PIR motion DETECTOR CIRCUIT DIAGRAM PIR datasheet PIR alarm system V0010 pir control 12V electromagnetic relay 74477
    Text: Security Systems Technical Data Dual Detectors EIM/B EIM/DB Description This new series of dual detectors is based on the proven detection principles of the EIM detector, consisting of a logical AND connection between infrared technology and electromagnetic fields.


    Original
    PDF D-69006 D-69123 D0201 PIR based security system infrared based security alarm "PIR wiring diagram PIR motion DETECTOR CIRCUIT DIAGRAM PIR datasheet PIR alarm system V0010 pir control 12V electromagnetic relay 74477

    CS2501

    Abstract: No abstract text available
    Text: GW-UDACT Universal Digital Alarm Communication Transmitter Description The Gamewell-FCI Universal Digital Alarm Communicator Transmitter GW-UDACT is designed for use with all Gamewell-FCI 600 Series Fire Alarm Control Panels. The GW-UDACT transmits the system status to UL-Listed Central Station Receivers via the public switched telephone


    Original
    PDF RS-485 24-volt CS-2501 CS2501

    Untitled

    Abstract: No abstract text available
    Text: TM Flex Series Conventional Fire Alarm System from Gamewell-FCI A Full, Flexible Range of Conventional Fire Alarms and Peripherals Control Panels Peripherals • Flex 402 and Flex 404 - Two and Four Zone Panels • Remote Annunciators and Control Modules • Flex 410 - Expandable Ten Zone Panel


    Original
    PDF

    visonic

    Abstract: visonic wireless PIR MCPIR-3000 MCR-308 MCR-304 k940 MCT-302 visonic alarm system MCT-211 12 f 5091
    Text: WIRELESS PowerCode Wireless Fully supervised wireless system Features • Code-Secure™ technology ■ Long-life lithium battery included ■ Fully supervised ■ Extended communication range ■ Attractive, elegant design ■ Anti-collision signaling


    Original
    PDF C-2250-9 MCPIR-3000 visonic visonic wireless PIR MCPIR-3000 MCR-308 MCR-304 k940 MCT-302 visonic alarm system MCT-211 12 f 5091

    PHOTO COUPLER

    Abstract: photo coupler specification DB22M162S-01 NDS-C-0110 DC24 DC24V EN61010-1 AA119
    Text: 2-phase STEPPING SYSTEMS Stepping DC input motor Specifications Stepping motors with internal drivers Features 1.Driver and motor are now integrated into a single unit. A driver incorporating a motion control function needed for driving a motor and a 2-phase stepping motor were


    Original
    PDF RS-485, 65inch 36inch 200ms PHOTO COUPLER photo coupler specification DB22M162S-01 NDS-C-0110 DC24 DC24V EN61010-1 AA119

    mag Reed Switch

    Abstract: N345 EN50130-4 Crow Detector LOCATION15 2aa "Battery Holder" xl-050 transmission battery condition tamper MAG SWITCH reed
    Text: 1 2 3 FW-MAG1 The FW -MAG1 as a part of the FREEWAVE wireless security system is an advanced, fully supervised low-current magnetic contact transmitter. The FW -MAG1 includes built-in reed switch and wired input for external reed switch. The FW -MAG1 is powered by an internal, long life


    Original
    PDF 24bit) 1-800-GET mag Reed Switch N345 EN50130-4 Crow Detector LOCATION15 2aa "Battery Holder" xl-050 transmission battery condition tamper MAG SWITCH reed

    RF8000

    Abstract: RF8200 RF8007 rf based intruder alarm 5 zone alarm system door bell RF8004 BA1002 SENSOR DOOR BELL RF8006
    Text: RF 80001RF8200 ADVANCE INTRUDER ALARM SYSTEM TABLE OF CONTENTS Title Page No. Introduction. Title Page No. Changing B a tteries.


    OCR Scan
    PDF RF8200 RF8000 RF8200 RF8000 RF8007 rf based intruder alarm 5 zone alarm system door bell RF8004 BA1002 SENSOR DOOR BELL RF8006

    STL-101

    Abstract: C 105 101 THERMOSTAT SPB-06
    Text: 3M”Wire Identification Products STL-100 Embossing Tool The 3M ScotchCode Embossing Tool STL-100 allows users to quickly produce slip-on 3M ScotchCode Wire M arker Tags that are legible and will always be easy to read. The unique STL-100 system is both compact and durable, perfect for field use,


    OCR Scan
    PDF STL-100 STL-101 STL-103. al54007-. C/140 SHB-01 C 105 101 THERMOSTAT SPB-06