Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    4200VRMS Search Results

    4200VRMS Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    EN 60742

    Abstract: 44202 44195 EI transformer 38/13.6 44193 44203 44201 44206 44194
    Text: 44000 Series EI 38-13.6 3.2 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 44202 44195 EI transformer 38/13.6 44193 44203 44201 44206 44194

    EN 60742

    Abstract: EI-30/18 en 60742 1,8 EN60742 2x128 44180 115 to 24 2.3 va transformer 44174 44158 44171
    Text: 44000 Series EI 30-18 2.3 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 EI-30/18 en 60742 1,8 EN60742 2x128 44180 115 to 24 2.3 va transformer 44174 44158 44171

    EN 60742

    Abstract: 44310 44318 443-18 EI 54/18 44302 44317 44306 TRANSFORMER ei 12 transformer 44305* "transformer"
    Text: 44000 Series EI 54-18.8 16VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 44310 44318 443-18 EI 54/18 44302 44317 44306 TRANSFORMER ei 12 transformer 44305* "transformer"

    EN 60742

    Abstract: en 60742 1,8 EN60742 EI 33 transformer 44023 44024 44018 #44018 44031 44027
    Text: 44000 Series EI 30-5 0.6 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 en 60742 1,8 EN60742 EI 33 transformer 44023 44024 44018 #44018 44031 44027

    EN 60742

    Abstract: ei 30-15.5 44134 44122 44127 transformer 44135 44130 EI-30 44126 EI 42 bobbin
    Text: 44000 Series EI 30-15.5 2 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 ei 30-15.5 44134 44122 44127 transformer 44135 44130 EI-30 44126 EI 42 bobbin

    EN 60742

    Abstract: 44229 EN60742 44233 EI 42/14.8 IEC85 4424 EI 42/14,8 44237 2X12
    Text: 44000 Series EI 42-14.8 5 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 44229 EN60742 44233 EI 42/14.8 IEC85 4424 EI 42/14,8 44237 2X12

    EN 60742

    Abstract: EN60742 en 60742 1,8 44071 an 44050 44066 Transformer 44067
    Text: 44000 Series EI 30-10.5 1 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 EN60742 en 60742 1,8 44071 an 44050 44066 Transformer 44067

    EI 42/14,8

    Abstract: EN 60742 EI-30/18 EI 33 transformer EI 33 bobbin EI 48/16,8 EI 16 bobbin 44108 44240 EI transformer 38/13.6
    Text: 44000 Series EI 30-5 0.6 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EI 42/14,8 EN 60742 EI-30/18 EI 33 transformer EI 33 bobbin EI 48/16,8 EI 16 bobbin 44108 44240 EI transformer 38/13.6

    EN 60742

    Abstract: en 60742 1,8 EN60742 44108 44087 44088 4409 EI-30 44101 44104
    Text: 44000 Series EI 30-12.5 1.5 VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 en 60742 1,8 EN60742 44108 44087 44088 4409 EI-30 44101 44104

    EN 60742

    Abstract: 30va transformer 443-89 EI 66/23 EN60742 44388 X1667
    Text: 44000 Series EI 66-23 30VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 30va transformer 443-89 EI 66/23 EN60742 44388 X1667

    EN 60742

    Abstract: X6112 EN60742 444,55 EN 60742 22va
    Text: 44000 Series EI 60-21 22VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 X6112 EN60742 444,55 EN 60742 22va

    EN 60742

    Abstract: 44278 EI 48/16,8 442-75 44272 44268 10VA 44266 IEC85 44265 transformer
    Text: 44000 Series EI 48-16.8 10VA Sealed Power Transformer FEATURES • UL and VDE Approvals • Vacuum Filled • Split Bobbin Design • Self-Extinguishing Plastics UL94V-O • Dielectric Strength 4200Vrms • Inherently energy limited • Resin Class B IEC 85 (20,000 h Testing to IEC 216)


    Original
    PDF UL94V-O 4200Vrms EN 60742 44278 EI 48/16,8 442-75 44272 44268 10VA 44266 IEC85 44265 transformer

    Untitled

    Abstract: No abstract text available
    Text: CLASS 2 TRANSFORMER FS12-500-C2 Description: The FS12-500-C2 is a series/parallel primary and dual secondary, split bobbin design which operates with either a parallel input of 115V or a series input of 230V. The secondaries are 6.3V @ 0.5A each. They can be used independently up to


    Original
    PDF FS12-500-C2 FS12-500-C2 4200VRMS 2011/65/EU, 50/60Hz

    RC snubber scr design

    Abstract: scr RC snubber design snubber relay scr snubber dc electromagnetic relay snubber RC snubber scr design for relay
    Text: GN3 Series 3 Phase Solid State Relay - DC Input Three-phase solid-state relay Ratings up to 50 amps @ 530Vac DBC substrate for superior thermal performance Epoxy-free design reduces internal com Back-to-Back dual SCR output for heavy industrial loads 100k-cycle UL508 endurance rating for enhanced reliability


    Original
    PDF 530Vac 100k-cycle UL508 48-600Vac 4-32Vdc RC snubber scr design scr RC snubber design snubber relay scr snubber dc electromagnetic relay snubber RC snubber scr design for relay

    BV302S12020

    Abstract: EI-30 BV302S09006 BV302D09015 EI30 bobbin BV302S12010 BV302S24010 BV302S12012 BV302S12006 BV302S18020
    Text: ZETTLER Magnetics, Inc. 75 COLUMBIA • ALISO VIEJO, CA 92656 • 949-360-5838 • FAX 949-360-5839 WEB SITE: HTTP://WWW.ZETTLERMAGNETICS.COM • E-MAIL: [email protected] FEATURES SEALED POWER TRANFORMERS BV SERIES EI30 0.6VA – 2.8VA ƒ UL & VDE CERTIFICATION


    Original
    PDF UL94V-0 4200Vrms BV301D06028 BV302D06028 BV301D09028 BV302D09028 BV301D12028 BV302D12028 BV301D15028 BV302D15028 BV302S12020 EI-30 BV302S09006 BV302D09015 EI30 bobbin BV302S12010 BV302S24010 BV302S12012 BV302S12006 BV302S18020

    BV302D09015

    Abstract: BV301S09015 BV302S09015 230v to 12v transformer ZETTLER Magnetics BV302S12015 BV302D06015 230V -15V TRANSFORMER EN61558-2-4 bv302S06015
    Text: SEALED TRANSFORMER, PCB 1.5VA El 30-12.5 SERIES 1. ELECTRICAL SPECIFICATIONS: A. Input Voltage and Frequency: 115/230V @ 50/60 Hz B. Secondary Voltage: See Electrical Table C. Ambient Temperature: 70° C MAX allowed. D. Insulation Resistance: 100M Ohm Min @ 500VDC


    OCR Scan
    PDF 115/230V 500VDC 4200Vrms UL506 UL1585 EN61558 EN60950 50/60Hz ta70/B 2x125 BV302D09015 BV301S09015 BV302S09015 230v to 12v transformer ZETTLER Magnetics BV302S12015 BV302D06015 230V -15V TRANSFORMER EN61558-2-4 bv302S06015

    BV302S09020

    Abstract: EN61558-2-4 ZETTLER Magnetics BV302D
    Text: SEALED TRANSFORMER, PCB 2VA El 30-15.5 SERIES 1. ELECTRICAL SPECIFICATIONS: A. Input Voltage and Frequency: 115/230V @ 50/60 Hz B. Secondary Voltage: See Electrical Table C. Ambient Temperature: 70° C MAX allowed. D. Insulation Resistance: 100M Ohm Min @ 500VDC


    OCR Scan
    PDF 115/230V 500VDC 4200Vrms UL506 UL1585 EN61558 EN60950 BV302D 50/60Hz 2008-2T BV302S09020 EN61558-2-4 ZETTLER Magnetics

    BV302S

    Abstract: BV302S12023 BV302S09023 transformer EN61558 la 1810 ZETTLER Magnetics BV302S06023 115 to 24 2.3 va transformer T70B
    Text: SEALED TRANSFORMER, PCB 2.3VA El 30-18 SERIES 1. ELECTRICAL SPECIFICATIONS: A. Input Voltage and Frequency: 115/230V @ 50/60 Hz B. Secondary Voltage: See Electrical Table C. Ambient Temperature: 70° C MAX allowed. D. Insulation Resistance: 100M Ohm Min @ 500VDC PRI. to SEC.


    OCR Scan
    PDF 115/230V 500VDC 4200Vrms UL506 UL1585 EN61558 EN60950 50/60Hz 0001D09023 BV301D12023 BV302S BV302S12023 BV302S09023 transformer EN61558 la 1810 ZETTLER Magnetics BV302S06023 115 to 24 2.3 va transformer T70B