ancol
Abstract: 240V
Text: Ancol AC/DC power Adapter AN116- 12W wall type C E Item No. Input Voltage AN116W12-3.3V2.0A 100~240V AN116W12-4.2V2.0A 100~240V AN116W12-4.5V2.0A 100~240V AN116W12-5.0V2.0A 100~240V AN116W12-6.0V2.0A 100~240V AN116W12-7.5V1.6A 100~240V AN116W12-8.4V1.4A 100~240V
|
Original
|
PDF
|
AN116-
AN116W12-3
AN116W12-4
AN116W12-5
AN116W12-6
AN116W12-7
AN116W12-8
AN116W12-9
AN116W12-12
ancol
240V
|
ancol
Abstract: AN116W24-5V4A AC adapter 12V2a 240V AN116W24-7 21v12 224w
Text: Ancol AC/DC power Adapter AN116- 24W wall type CE Item No. Input Voltage AN116W24-3.3V4A 100~240V AN116W24-4.2V4A 100~240V AN116W24-4.5V4A 100~240V AN116W24-5V4A 100~240V AN116W24-6V4A 100~240V AN116W24-7.5V3.2A 100~240V AN116W24-8.4V2.85A 100~240V AN116W24-9V2.6A
|
Original
|
PDF
|
AN116-
AN116W24-3
AN116W24-4
AN116W24-5V4A
AN116W24-6V4A
AN116W24-7
AN116W24-8
AN116W24-9V2
AN116W24-12V2A
ancol
AN116W24-5V4A
AC adapter 12V2a
240V
21v12
224w
|
regavolt
Abstract: Lyons regavolt 1225 Claude Lyons Claude k 1225 transformer 240v 115-OF 187VA regavolt 715
Text: Regavolt Claude Lyons Variable Transformers Model 715 Model Specifications 301 404 Nominal Input Voltage 250V Load Rating 187VA 715 1225 240V 240V 240V 1.14kVA 4.3kVA 7.2kVA Line-voltage connection 0 to 100% of input Output Voltage Over-voltage connection 0 to 115% of input
|
Original
|
PDF
|
187VA
14kVA
300mm
230/240/250V
2003/a
regavolt
Lyons
regavolt 1225
Claude Lyons
Claude
k 1225
transformer 240v
115-OF
187VA
regavolt 715
|
Untitled
Abstract: No abstract text available
Text: Roof-Mounted Fan Panel, 208-240V 6 high-performance fans; 420 CFM; C14 inlet; toolless mounting. Highlights Roof Mount Fan Panel 208-240V Ideal for increasing the ventilation of SmartRacks MODEL NUMBER: SRXFANROOF Features (6) 208-240V fans mounted in a roof panel
|
Original
|
PDF
|
08-240V
08-240V
50/60Hz
|
07380
Abstract: simpson model 29
Text: Frequency Meter Specifications • Plastic case with Glass Window • Calibration not affected when mounted on steel • Three popular sizes: 2-1/2”, 3-1/2”, 4-1/2” Accuracy 45-55Hz ±0.3Hz 120V-240V 55-65Hz ±0.3Hz (120V-240V) 380-420Hz ±1.2Hz (120V-240V)
|
Original
|
PDF
|
45-55Hz
20V-240V)
55-65Hz
380-420Hz
50/60/400Hz
07380
simpson model 29
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Switched PDU, 5/5.8kW 30A 208/240V, 2U Horizontal Rackmount, 16 C13 outlets, NEMA L6-30P input plug Highlights Switched 30A 208/240V PDU, 2U horizontal rackmount format Reports voltage, frequency & load level via ethernet interface MODEL NUMBER: PDUMH30HVNET
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
PDUMH30HVNET
com/sku/PDUMH30HVNET.
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Switched PDU with outlet level metering, 5/5.8kW 30A 208/240V, 0U Vertical Rackmount, C19 & C13 outlets, L6-30P input Highlights Switched 30A 208/240V PDU, 0U 70 in. / 178cm Vertical Rackmount Format Reports voltage, frequency & MODEL NUMBER: PDUMVR30HVNET
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
178cm
PDUMVR30HVNET
IEC-320-C19
IEC-320-C14)
P047-004
14AWG
|
U20N2K2S
Abstract: U20N1K5S Vat20 u20x2k2 FORWARD REVERSE 3 PHASE MOTOR 3 wiring control diagram with run and jog U20X0K7S U20N0K7S frequency inverter tverter single phase inverter IGBT driver 50 kva U20N0K4S GE DC DRIVE 460V ADJUSTABLE SPEED DRIVE
Text: GE Power Controls VARIABLE SPEED DRIVE UNIT INVERTER VAT20 1ph 200V-240V system, 0.2-0.75kW 1ph/3ph 200/240V system, 1.5-2.2kW 3ph 380/460V system, 0.75-2.2kW INSTRUCTION MANUAL - NOTICE -1.
|
Original
|
PDF
|
VAT20
00V-240V
200/240V
380/460V
VAT20,
89/336/EEC)
U20X1K5
U20X2K2
U20AF2K2
U20N2K2S
U20N1K5S
Vat20 u20x2k2
FORWARD REVERSE 3 PHASE MOTOR 3 wiring control diagram with run and jog
U20X0K7S
U20N0K7S
frequency inverter tverter
single phase inverter IGBT driver 50 kva
U20N0K4S
GE DC DRIVE 460V ADJUSTABLE SPEED DRIVE
|
Untitled
Abstract: No abstract text available
Text: ESD-A24T5S Type: Programmed Start Electronic Ballast Lamp Connection: Dual Lamps in Series Lamp Types: One or Two 24 Watt F24T5 SLI lamps or cross reference Philips, Sylvania/OSRAM, or GE Rapid Start lamps SPECIFICATIONS Input Voltage 120V 120V 220/240V 220/240V
|
Original
|
PDF
|
ESD-A24T5S
F24T5
220/240V
F24T5
|
Untitled
Abstract: No abstract text available
Text: Single Phase Monitored PDU, 5/5.8kW 30A 208/240V, 2U Horizontal Rackmount, 12 C13 and 4 C19 outlets, NEMA L6-30P input plug Highlights Monitored 30A 208/240V PDU, 2U horizontal rackmount Reports voltage, frequency & load level via ethernet interface MODEL NUMBER: PDUMNH30HV
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
PDUMNH30HV
P036-006-2C19
P036-002-20LA
12AWG
IEC-320-C19
IEC-320-C20
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Metered PDU, 5/5.8kW 30A 208/240V, 0U Vertical Rackmount, 6 C19 and 24 C13 outlets, NEMA L6-30P input plug Highlights Metered single phase 30A 208/240V, 0U 63.75in / 162cm vertical rackmount PDU Pair of digital meters report MODEL NUMBER: PDUMV30HV
|
Original
|
PDF
|
208/240V,
L6-30P
162cm
PDUMV30HV
10-ft.
14AWG
IEC-320-C19
IEC-320-C14)
|
Untitled
Abstract: No abstract text available
Text: Single-Phase ATS / Switched PDU, 3.2-3.8kW 16/20A 200-240V, 1U Horizontal Rackmount, 8 C13 and 2 C19 outlets, 2 C20 inputs Highlights Single phase 16/20A 200-240V Auto Transfer Switch / ATS PDU Enables redundant power options for single-corded network devices
|
Original
|
PDF
|
16/20A
00-240V,
00-240V
PDUMH20HVATNET
P052-008
IEC-320-C19
BS1363
P070-010
10-ft.
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Monitored PDU, 5/5.8kW 30A 208/240V, 0U Vertical Rackmount, 36 C13 & 6 C19 outlets, NEMA L6-30P input plug Highlights Monitored 30A 208/240V PDU in 0U 70in / 178cm vertical rackmount format Reports voltage, frequency and MODEL NUMBER: PDUMNV30HV2
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
178cm
PDUMNV30HV2
IEC-320-C19
IEC-320-C14)
P047-004
14AWG
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Monitored PDU, 3.2-3.8kW 16/20A 200-240V, 1U Horizontal Rackmount, 8 C13 outlets, C20 input with L6-20P adapter Highlights Monitored 16/20A 200-240V PDU, 1U horizontal rackmount Reports voltage, frequency & load level via ethernet interface MODEL NUMBER: PDUMNH20HV
|
Original
|
PDF
|
16/20A
00-240V,
L6-20P
16/20A
00-240V
PDUMNH20HV
IEC-320-C20)
P036-002-20LA
12AWG
|
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Metered PDU, 3.2-3.8kW 16/20A 200-240V, 1U Horizontal Rackmount, 2 C19 and 8 C13 outlets, C20 input with NEMA L6-20P adapter Highlights Metered single phase 16/20A 200-240V PDU 1U horizontal rackmount; digital current meter MODEL NUMBER: PDUMH20HV
|
Original
|
PDF
|
16/20A
00-240V,
L6-20P
00-240V
PDUMH20HV
P070-010
10-ft.
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Basic PDU, 5/5.8kW 30A 208/240V, 1U Horizontal Rackmount, 4 C19 and 16 C13 outlets, NEMA L6-30P input plug Highlights Basic single phase 30A 208/240V PDU 1U horizontal rackmount installation MODEL NUMBER: PDU1230 NEMA L6-30P input; 15 ft. / 4.5m
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
PDU1230
19-inch
IEC-320-C19
IEC-320-C14)
P047-004
14AWG
|
AC240V
Abstract: 47Hz-63Hz AC220-240V
Text: ELECTRICAL CHARACTERISTICS NO ITEM SPECIFICATIONS CONDITION 1 INPUT AC 90~264V RATED AC 100~240V 2 FREQUENCY 47Hz~63Hz 3 INRUSH CURRENT 30A MAX. RATED 50/60Hz AC 240V, RATED LOAD 25°C COLD START 4 EFFICIENCY 80% TYP. 5 LEAKAGE CURRENT 0.50mA MAX. 6 RATED OUTPUT
|
Original
|
PDF
|
50/60Hz
100mVp-p
AC240V/60Hz
AC120V/60Hz
AC240V
47Hz-63Hz
AC220-240V
|
SXH-001T-PO
Abstract: B3P5 CSA22 JY121R2G 20Atyp
Text: 15 Watt JY Series FEATURES • • • • • • SPECIFICATIONS INPUT Voltage Full Load 120V 0.2 - 0.4 RMS 240V 0.1 - 0.2 (RMS) Inrush 120V - 20A (TYP) 240V - 40A (TYP) OUTPUT Total Regulation Ripple & Noise (peak-to-peak) Hold-up Time Start-up Time PROTECTION
|
Original
|
PDF
|
100mV
SVH-21Tk-P1
SXH-001TPO
SXH-001T-PO
B3P5
CSA22
JY121R2G
20Atyp
|
AC emi filter 240V
Abstract: CSA22 30W30W
Text: 30 Watt JY Series FEATURES • • • • • • SPECIFICATIONS INPUT Voltage Full Load 120V 0.5 - 0.7 RMS 240V 0.25 - 0.35 (RMS) Inrush 120V - 20A (TYP) 240V - 40A (TYP) OUTPUT Total Regulation Ripple & Noise (peak-to-peak) Hold-up Time Start-up Time
|
Original
|
PDF
|
100mV
AC emi filter 240V
CSA22
30W30W
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Switched PDU, 5/5.8kW 30A 208/240V, 2U Horizontal Rackmount, 8 C13 and 6 C19 outlets, NEMA L6-30P input plug Highlights Switched 30A 208/240V PDU, 2U horizontal rackmount format Reports voltage, frequency & load level via ethernet interface MODEL NUMBER: PDUMH30HV19NET
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
PDUMH30HV19NET
IEC-320-C19
IEC-320-C14)
P036-002
12AWG
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Basic PDU, 3.3/3.8kW 20A 208/240V, 1U Horizontal Rackmount, 2 C19 and 12 C13 outlets, NEMA L6-20P input plug Highlights Basic single phase 20A 208/240V PDU 1U horizontal rackmount installation MODEL NUMBER: PDUH20HVL6 L6-20P input; 15 ft. / 4.5m line
|
Original
|
PDF
|
208/240V,
L6-20P
208/240V
PDUH20HVL6
PDUH20HVL6
IEC-320-C19
IEC-320-C14)
P047-010
10-ft.
|
Untitled
Abstract: No abstract text available
Text: Single-Phase Switched PDU, 5/5.8kW 30A 208/240V, 0U Vertical Rackmount, 20 C13 and 4 C19 outlets, NEMA L6-30P input plug Highlights Switched 30A 208/240V PDU; 70in / 178cm 0u Vertical Rackmount Reports voltage, frequency & MODEL NUMBER: PDUMV30HVNET loading information via ethernet
|
Original
|
PDF
|
208/240V,
L6-30P
208/240V
178cm
PDUMV30HVNET
IEC-320-C19
IEC-320-C14)
P047-004
14AWG
|
trumeter 7250
Abstract: trumeter M261NX 4 pin din DIN CONNECTION adaptor AC to DC ScansUX67
Text: 5-240V Adaptor Module 7250 DIN SPECIFICATION: Timing Inputs: 5 to 48V AC /D C and 48 to 240V AC/DC 50mS m in pulse length. Input Impedance: 5 to 48V input: 10Kohm 48 to 240V input: 58.5K ohm Reset input: C ontact closure only via external volt free co nta ct. 15mS (m in) co n ta ct ON time.
|
OCR Scan
|
PDF
|
10Kohm
8-240V
M261NX,
trumeter 7250
trumeter
M261NX
4 pin din
DIN CONNECTION
adaptor AC to DC
ScansUX67
|
trumeter 7250
Abstract: trumeter 7500D ic 7500
Text: 7¿a/M&sâ C€ 5-240V Adaptor Module 7250 DIN S P E C IF IC A T IO N : Timing Inputs: Input Impedance: 5 to 48V -“V— and 48 to 240V - V “ 50mS min pulse length. 5 to 48V input. 4K7ohm 48 to 240V input: 58.5Kohm Contact closure only via external volt free contact. 15mS (min) contact ON time.
|
OCR Scan
|
PDF
|
8-240V
DIN/7510
trumeter 7250
trumeter
7500D
ic 7500
|