Please enter a valid full or partial manufacturer part number with a minimum of 3 letters or numbers

    230V DC TO 440V AC Search Results

    230V DC TO 440V AC Result Highlights (5)

    Part ECAD Model Manufacturer Description Download Buy
    D1U74T-W-1600-12-HB4AC Murata Manufacturing Co Ltd AC/DC 1600W, Titanium Efficiency, 74 MM , 12V, 12VSB, Inlet C20, Airflow Back to Front, RoHs Visit Murata Manufacturing Co Ltd
    D1U54T-M-2500-12-HB4C Murata Manufacturing Co Ltd 2.5KW 54MM AC/DC 12V WITH 12VDC STBY BACK TO FRONT AIR Visit Murata Manufacturing Co Ltd
    MGN1S1208MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-8V GAN Visit Murata Manufacturing Co Ltd
    MGN1D120603MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-6/-3V GAN Visit Murata Manufacturing Co Ltd
    MGN1S1212MC-R7 Murata Manufacturing Co Ltd DC-DC 1W SM 12-12V GAN Visit Murata Manufacturing Co Ltd

    230V DC TO 440V AC Datasheets Context Search

    Catalog Datasheet MFG & Type PDF Document Tags

    Untitled

    Abstract: No abstract text available
    Text: Mini contactors Mini contactors providing various connections and Accessories Screw clamps Fast-on For conventional screw connections For fast-on connections Ratings AC3 ratings IEC60947-4 Frame size 6A 9A 12A 380 ~ 500 ~ 240V 440V 550V 1.5kW 2.2kW 3kW 3kW


    Original
    PDF IEC60947-4) CGMS-12D CGMUS-12A CGMUS-12D CGMS-12A

    Untitled

    Abstract: No abstract text available
    Text: ShortFormIndustrialRelays.QXD_Industrial Relays 4/2/13 9:45 AM Page 1 ShortFormIndustrialRelays.QXD_Industrial Relays 4/2/13 9:45 AM Page 2 Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff of


    Original
    PDF 725-032013-1M

    potential transformer 230v ac

    Abstract: 230v dc to 440v ac 440v ac to 24v dc E1F3 DC230V 1000VA relay latch
    Text: TUW4X Monitoring relays – TREND series Industrial design Width 45mm AC/DC voltage monitoring in 1-phase mains Fault latch Position of output relay presettable 1 change over contact Technical data 1. Functions AC/DC voltage monitoring in 1-phase mains with adjustable


    Original
    PDF

    140M-C-AFA11

    Abstract: 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16
    Text: MCS MINIATURE CONTACTORS SELECTION GUIDE THE MINIATURE MODULAR CONTROL SYSTEM SMALL IN DIMENSIONS - BIG IN PERFORMANCE DOL-Starter Overload Protection Short Circuit Protection DOL-Starter Overload Protection PROTECTION FOR AC AND DC MOTORS • The Bulletin 193-K thermal


    Original
    PDF 193-K 100-K 140-M MCS-SG001A-EN-P 140M-C-AFA11 100-K05ZJ10 140M-C-PEK12 140M-C2E-C10 140M-C2E-B10 140M-C2E-C25 Allen-Bradley 100-k12 100-k05 140M-C-W454 140M-C2E-B16

    3phase winding data 3.7 kw to 110 kw

    Abstract: J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v
    Text: Motor Contactor J7KN Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessories • front mounted single pole additional auxiliary contacts


    Original
    PDF 380/415V) J7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw J73KN-b-01 ICE 947 EN 60947 3 phase, 415v and 37 kw motor yd 803 J7KN110 3 phase, 415v and 270 kw motor EM- 546 motor wiring diagram 3 phase dol compressor Starting Current 7.5KW Motor 440v

    Sprecher Schuh LE 2-16

    Abstract: TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719
    Text: Contactors - AC Coil Four Pole - Series CA7 A Non-Reversing, Four Pole Contactors With AC Coil, Series CA7 Open type only Contactors Ratings for Switching AC Motors (AC2 / AC3 / AC4) Open Type Contact Configuration, Ie [A] kW (50 Hz) UL/CSA HP (60 Hz) Main Pole Catalog


    Original
    PDF CA7-9-M40- CA7-9-M31- CA7-9-M22- CA7-12-M40- CA7-12-M31- CA7-12-M22- Sprecher Schuh LE 2-16 TE404 Sprecher Schuh LE 2-20 Sprecher Schuh CA 3-9 m40 Sprecher Schuh CA 3-9 Sprecher Schuh LE 2-12 sprecher and schuh ca 4-9 TA473 CRD7-250 TD719

    VDE 0660 iec 158-1

    Abstract: NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660
    Text: 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ 40A Rated insulation voltage Ui (Conforming to IEC 158-1) V IEC 60947-4 V Conforming to standards 750 1000 NFC63-110, VDE0660, BS5424, JEM1038 & IEC60947-4


    Original
    PDF NFC63-110, VDE0660, BS5424, JEM1038 IEC60947-4 VDE 0660 iec 158-1 NFC-63110 IEC 158-1 VDE 0660 NFC63-110 32A 4 pole relay 230v ac JEM1038 iec 947-4 BS5424 IEC 158-1 VDE 0660 DC contactor 220V VDE0660

    Thermal Overload Relay GTH-22

    Abstract: GMC-16m GTH-22 SMC-25P2 GMC-400 GMC-220 GMC-300 smc-30p2 GMC-16MP GMC-600
    Text: Contactors 9 to 85A 9A Frame size 12A 18A 22A 3-pole Contactors For further technical information see pages 8-9. Types includes AU-1 auxililary switch, (1 N.O. / 1 N.C.) AC coil DC coil Ratings / IEC60947-4 AC1 AC3 200/240V 380/440V 500/550V 690V Ratings / UL508


    Original
    PDF IEC60947-4 200/240V 380/440V 500/550V UL508 GMC-12 GMD-12 GMC-18 GMD-18 GMC-22 Thermal Overload Relay GTH-22 GMC-16m GTH-22 SMC-25P2 GMC-400 GMC-220 GMC-300 smc-30p2 GMC-16MP GMC-600

    3phase winding data 3.7 kw to 110 kw

    Abstract: 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor
    Text: Motor Contactor Main contactor • AC & DC operated • Integrated auxiliary contacts • Screw fixing and snap fitting 35 mm DIN rail up to 45 kW W • Range from 4 to 110 kW (AC 3, 380/415V) • Finger proof ( VBG 4) Accessoires • front mounted d single pole additional auxiliary contacts


    Original
    PDF 380/415V) Conta7KN-10-01 J7KN-22-01 J7KN-150-11 J7KN-175-11 J7KN-24 J7KN-32 J7KN-40 J7KN-50 J7KN-62 3phase winding data 3.7 kw to 110 kw 1000v contactor J7KN-22-01 j7kn-32 J73KN-b-01 KNC 201 15 yd 803 knc 201 39 wiring diagram to hold contactor with NO, NC controls for 22kw motor

    KD 605

    Abstract: G700 100-FLAM5 bs 5424 380V 415v motor 100G1000 100-EF22 100-CP550 TZS734 5A 1 pole relay 220v ac
    Text: Bulletin 100-G — IEC Contactors Table of Contents Selection Guide Description Page Bulletin 100-G IEC Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Bulletin 100-G IEC Contactors 1 Bulletin 100-G Contactors • • • • • • •


    Original
    PDF 100-G 100-G 60V/575V 100-G550/100-G700, 100-G700, -860/100-G1000, -860/100-G700, KD 605 G700 100-FLAM5 bs 5424 380V 415v motor 100G1000 100-EF22 100-CP550 TZS734 5A 1 pole relay 220v ac

    190-CPS40

    Abstract: 380V 415v motor 190-A40 190-MN 190-CPS40D 190-P400R 3 phase, 415v and 45 kw motor 190-P320R 190-P040R contactor 190-a40
    Text: Bulletin 190 — IEC Modular Starter System Table of Contents Selection Guide Description Page Bulletin 190 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF 190-CL1 190-A22C 190-A11/11 190-A11C 190-N3, 190-SG001A-US-P 190-CPS40 380V 415v motor 190-A40 190-MN 190-CPS40D 190-P400R 3 phase, 415v and 45 kw motor 190-P320R 190-P040R contactor 190-a40

    VDE 0660 iec 947-2

    Abstract: gps1bh GE Contactor uimp 8kV SFAL11N GPS1bsah SFVH03 GPAC11LLA GPEF55A ge contactor 0660T
    Text: 39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection formerly GE Power Controls , a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical


    Original
    PDF H-1340 B-9000 C/4601/E/EX VDE 0660 iec 947-2 gps1bh GE Contactor uimp 8kV SFAL11N GPS1bsah SFVH03 GPAC11LLA GPEF55A ge contactor 0660T

    digital 3 phase voltmeter and ammeter

    Abstract: AC digital voltmeter and ammeter 3 phase analog voltmeter and ammeter AC digital voltmeter digital 3 phase voltmeter WATT and ammeter analog panel meter digital phase voltmeter and ammeter GR72-3DV digital Ammeter circuit VAR meter
    Text: com.greegoo.www Greegoo Elextric Co.,Ltd. 2007 Panel Meters Introduction Panel Meters and Accessories 1- Digital Panel Meter Specification: HCD19 - □ □- □ X □ The instruments comply with IEC51 Over load 1. Product code 2. Input Signal Mode 4-AC signal input 5-DC signal


    Original
    PDF HCD19 IEC51 4--48X48 5--96X48 7--72X72 9--96X96 GR96-3PF3 GR96-3PF1 96x96 digital 3 phase voltmeter and ammeter AC digital voltmeter and ammeter 3 phase analog voltmeter and ammeter AC digital voltmeter digital 3 phase voltmeter WATT and ammeter analog panel meter digital phase voltmeter and ammeter GR72-3DV digital Ammeter circuit VAR meter

    Allen-Bradley 100-k12

    Abstract: 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10
    Text: SELECTION GUIDE BULLETIN 100-K Miniature Modular Control Sytstem 2 Bulletin 100-K, 700-K, 193-K, 140M, 140F IEC Miniature Contactors Selection Overview IEC Miniature Contactors • Bulletin 100/104-K Miniature Contactors Page 4 IEC Miniature Control Relays


    Original
    PDF 100-K 100-K, 700-K, 193-K, 100/104-K 700-K 193-K 100/104-K 100K-SG001A-EN-P Allen-Bradley 100-k12 140M-C-ASA11 140m-c-wte 100-KFSD250 100-K09 140M-C-AFA11 100-KFC22 140M-C-WBE 100-KFSV55 100-K05ZJ10

    rac 16a 400v

    Abstract: BW250EAG BW250JAGU
    Text: Molded Case Circuit Breakers List of products G-TWIN Standard Series IEC/EN/GB/JIS conformed Line protection Motor protection AC415V BW32 BW50 BW63 BW100 BW125 BW160 BW250 BW400 BW630 BW800 AC415V BW32 BW50 BW63 BW100 BW125 BW250 Icu Icu 1.5kA AAG AAG 2.5kA


    Original
    PDF AC415V BW100 BW125 BW160 BW250 BW400 BW630 BW800 rac 16a 400v BW250EAG BW250JAGU

    relay for controlling 230v ac using 5v

    Abstract: 230V AC to 5V DC ic 230 AC to 5V dc transformer transformer from 230V AC to 5V DC 661 Optocoupler 230v AC to 60v dC transformer circuit diagram P 721 "OPtOCOUPlER" 230v ac to 32v dc without transformer optocoupler ic OPTOCOUPLER thyristor
    Text: M. K. JUCHHEIM GmbH & Co JUMO Instrument Co. Ltd. JUMO PROCESS CONTROL INC. Delivery address:Mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 60 03-0 Fax: +49 661 60 03-6 07 E-mail: [email protected] Internet: www.jumo.net


    Original
    PDF 1-800-554-JUMO relay for controlling 230v ac using 5v 230V AC to 5V DC ic 230 AC to 5V dc transformer transformer from 230V AC to 5V DC 661 Optocoupler 230v AC to 60v dC transformer circuit diagram P 721 "OPtOCOUPlER" 230v ac to 32v dc without transformer optocoupler ic OPTOCOUPLER thyristor

    NFC 63-110

    Abstract: MREBC20AC2 RL4RD022T VDE 0660 BS 4794 MCRA022AT RL4RA022T TIMER ON DELAY 220V AC PRC4M30CDL BSLR2R MCRC031AT
    Text: 39584 GE Consumer & Industrial Power Protection GE Consumer & Industrial Power Protection formerly GE Power Controls , a division of GE Consumer & Industrial, is a first class European supplier of low-voltage products including wiring devices, residential and industrial electrical


    Original
    PDF H-1340 B-9000 C/4601/E/EX NFC 63-110 MREBC20AC2 RL4RD022T VDE 0660 BS 4794 MCRA022AT RL4RA022T TIMER ON DELAY 220V AC PRC4M30CDL BSLR2R MCRC031AT

    relay 12v 6a

    Abstract: relay 24v 5a 12v relay 12V electromechanical relay knife edge isolation relay railway relay dc 24v ac 250v 16a 230V ac relay AC300V Z80000
    Text: interface flare Coupling relays The safe way to achieve a perfect interface in process applications. In the microchip age of bits and bytes, one might assume that there is no place left for electromechanical relays. Far from it! In control, transportation and


    Original
    PDF 35-mm relay 12v 6a relay 24v 5a 12v relay 12V electromechanical relay knife edge isolation relay railway relay dc 24v ac 250v 16a 230V ac relay AC300V Z80000

    interposing relay

    Abstract: Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04
    Text: Bulletin 500 Line Open Type Modular Kits and Components Selection Guide Bulletin 500, 500F, 509 NEMA AC Contactors and Starters Product Overview NEMA AC Contactor and Starter Modular Kits and Components NEMA sizes 0…4 for open-type Bulletin 500 top-wired contractors, Bulletin 500F feed-through contactors, and Bulletin 509 fullvoltage starters, are provided as modular kits for faster delivery. Other sizes and enclosed-type devices are also available.


    Original
    PDF 800T/H 500-SG008A-EN-P interposing relay Allen-Bradley auxiliary contact 595-A 500F-BOD930 592-EUTB 592-EEHE 509-FOD 599-KA04 509-BOD Bulletin 709 Motor Starter Coil 599-k04

    LC1-D09

    Abstract: dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25
    Text: Motor Control Device 1-1 Magnetic latching contactors GCR1-F series magnetic latching contactors Magnetic latching contactors of both block and bar mounted types are fitted with a special electromagnet which enables them to remain in the "On" position when the coil is no longer energised.


    Original
    PDF GLE1-D09 GLE1-D018 GLE1-D25 GLE1-D32 GLE1-D40 GLE1-D95 LC1-D09 dimension LC1-D09 LC1-D25 LC1-D09 installation manual LC1-D25 wiring LC1-D2500 LP1-D09 380V 415v motor LC1 D25008 LP1-D25

    NEMA P600

    Abstract: No abstract text available
    Text: CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications CS7 Industrial Control Relays share the same design as our modern CA7 contactor range. They are compact and designed for heavy duty industrial control applications where reliability


    Original
    PDF AC-15) SSNA2014 NEMA P600

    IEC 947 EN 60947

    Abstract: Allen-Bradley contactors 100s Allen-Bradley 100-FSD250 lr13908 100-FSC280 100-SA10 IEC 158-1 VDE 0660 DIN19240 700S-CF440DJC Allen-Bradley contactor 100s-c09
    Text: Bulletin 100S-C/104S-C Safety Contactors Bulletin 700S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin 100S-C/104S-C Safety Contactors Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


    Original
    PDF 100S-C/104S-C 700S-CF 100S-C/104S-C S-C3004C. C8504C 100S-C09404C. C23404C 100S-C09304C. IEC 947 EN 60947 Allen-Bradley contactors 100s Allen-Bradley 100-FSD250 lr13908 100-FSC280 100-SA10 IEC 158-1 VDE 0660 DIN19240 700S-CF440DJC Allen-Bradley contactor 100s-c09

    CA3-9-10

    Abstract: Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10
    Text: Accessories – Field Installable CA7 Contactors Contact Block Description NO NC Contact Arrangement Standard Contacts Catalog For use with. Number Bifurcated Contacts Catalog Price Number ➋ Price 51 61 2 CA7 all CS7-PV-02 27 CS7-PVB-02 42 CA7-30.97-✱-00


    Original
    PDF CS7-PVB-02 CA7-PV-02 CA7-PVB-02 CS7-PV-11 CS7-PVB-11 CA7-30. CA7-PV-11 CA7-PVB-11 CA7-PV-S11 CA7-PVB-S11 CA3-9-10 Sprecher Schuh ca3 Sprecher Schuh ca3-23-10 Sprecher Schuh CA3-12-10 Sprecher Schuh ca3-16-10 CA3-12-10 Sprecher Schuh TE404 ca3 contactor CA3-16-10

    3 phase AC voltage regulator for 440v

    Abstract: D24SCT 440v ac voltage regulator 440v ac to 24v dc 1000VA 230v switching regulator dc 230v DC motor control circuit insulation monitoring device
    Text: D24SCT Monitoring relays – DELTA series Industrial design Width 45mm Power factor monitoring in 1- and 3-phase mains Temperature monitoring of the motor winding max. 6 PTC Suitable for VFI (10 to 100Hz) Position of output relays presettable 2 change over contacts


    Original
    PDF D24SCT 100Hz) 3 phase AC voltage regulator for 440v D24SCT 440v ac voltage regulator 440v ac to 24v dc 1000VA 230v switching regulator dc 230v DC motor control circuit insulation monitoring device